Filter piston type adjustable pressure reducing valve
I. Introduction:
The filtered piston-type adjustable pressure reducing valve automatically operates the upward and downward movement of the main valve disc using the water pressure in the pipeline, controls the opening degree of the valve, adjusts the downstream pressure, and maintains the downstream pressure at the set value of the pilot valve spring. When the downstream pressure exceeds the set value, the pressure reducing valve will automatically close. Regardless of how the inlet pressure fluctuates, it can output a stable outlet pressure. No matter how the downstream flow changes, it can maintain the outlet pressure stably above the pilot valve's set value. At the same time, the outlet pressure adjusted by the pilot valve has a large adjustment range, which can reach 10-80% of the upstream pressure. It is generally used in domestic water supply, fire protection and industrial water supply systems.
II. Features:
1. The pitot tube transmits pressure signals to the highly sensitive flow-limiting pilot valve. There is no orifice plate throttling, no pressure loss, and it is energy-saving.
2. The flow-limiting pilot valve has a highly sensitive spring to adjust the flow rate, which is simple and accurate to operate.
3. Y-shaped wide valve cavity, small flow resistance, strong cavitation resistance.
4. Self-controlled by the pressure of the medium itself, no external power source is required.
5. A filter is installed between the inlet flange of the main valve body and the valve seat, saving investment and installation costs.
6. Both inner and outer surfaces are sprayed with environmental protection coatings, ensuring the product's corrosion resistance and safety.
III. Parts:
Part Name | Material |
Valve body, valve cover | Cast iron, cast steel, stainless steel |
Valve seat | Tin bronze, stainless steel |
Valve disc | Carbon steel, stainless steel + rubber |
Valve stem | Aluminum bronze, chromium stainless steel |
Piston | Chromium stainless steel + rubber |
Filter screen | Stainless steel |
Spring | Stainless steel |
IV. Performance Parameters:
Nominal Pressure (MPa) | Shell Test Pressure (MPa) | Seal Test Pressure (MPa) | Pressure Adjustment Range (MPa) | Slow Closing Time (s) | Minimum Operating Pressure (MPa) | Applicable Medium | Medium Temperature (℃) |
1.0 | 1.5 | 1.1 | 0.09-0.8 | 3-60 | ≥0.07 | Water | 0-80 |
1.6 | 2.4 | 1.76 | 0.15-1.4 | ||||
2.5 | 3.75 | 2.75 | 0.2-2.0 |
| Machinery & Equipment/Valves/Pressure Reducing Valves | |