Multi-view Visual Monitoring and Shooting Device for Transmission Lines
Contact Info
- Building C-9, Floor C, Precision达 Industrial Park, No.39 Qingfeng Avenue, Longgang Sub-district, Longgang District, Shenzhen City, 518116
- 李女士
- 13682351635
- 1920671927@qq.com
Product Alias: Multi-lens Camera Monitoring Device, Transmission Channel Visual Monitoring and Shooting Channel External Damage Device, Transmission Line Visual Online Monitoring Device
Product Model: TLKS-PMG-100BM
Transmission Line Multi-angle Visual Monitoring and Shooting Device
I. Product Description:
Transmission Line Multi-angle Visual Monitoring and Shooting Device TLKS-PMG-100BM is mainly used for remote real-time monitoring of the operation status and surrounding environment of transmission lines. It has powerful data processing and storage functions, and can transmit monitoring data and video information to the monitoring center in real time. Staff can remotely monitor the safety of transmission lines, perceive potential safety incidents on site in real time, and improve the efficiency of line operation and maintenance management and control.
II. Working Principle:
This device is usually composed of multiple monitoring cameras, pan-tilts, data transmission modules, etc. High-definition cameras are responsible for shooting video images of transmission lines and surrounding environments, pan-tilts are responsible for controlling the rotation and pitch angles of the cameras to achieve all-round monitoring. The data transmission module transmits the video images and monitoring data shot by the cameras to the monitoring center. During transmission, the data is compressed and processed to reduce the requirements for transmission bandwidth and storage space. When an abnormal situation occurs on the transmission line, the device will automatically trigger an alarm mechanism, send an alarm to the staff, and automatically record the information of the abnormal situation, facilitating subsequent processing and investigation.
III. Product Functions:
Adopts an integrated design of industrial-grade high-definition dual-side dual-lens camera and pan-tilt camera;
Equipped with lenses and optical zoom pan-tilt cameras that can monitor the large and small dual-side line channels respectively;
Both dual-side line channels are equipped with day and night lenses, capable of collecting high-definition full-color image data 24 hours a day;
The angles of both dual-side cameras support manual adjustment, and support vertical adjustment to adapt to the installation environment of up and down slopes
IV. Technical Parameters:
The pixel of the camera monitoring the line channel during the day is not less than 16 million, and the image resolution is not less than 4608×3456;
The camera monitoring the line channel at night adopts a 1/1.8 starlight-level camera, with a pixel of not less than 2 million, and the image resolution is not less than 1920×1080;
The pan-tilt camera, optical zoom camera has a pixel of not less than 2 million, image resolution not less than 1920*1080, and optical zoom multiple ≥20 times;
Strong anti-electromagnetic interference capability, suitable for complex environments such as the power industry;
Low-power design, supports wide-voltage input, suitable for solar power supply;
High temperature resistance up to 70℃, low temperature resistance down to -40℃; protection performance meets IP66
Built-in 4G full Netcom module;
Supports transmission protocols of State Grid and China Southern Power Grid, the monitoring and shooting device can have a built-in security encryption chip to realize encrypted transmission of data and ensure data security;
V. Summary:
Transmission Line Multi-angle Visual Monitoring and Shooting Device is a very effective transmission line monitoring device. It can improve the safety and reliability of transmission lines and ensure the stable operation of the power system. At the same time, the application of this device can also reduce inspection costs, reduce the workload of inspection personnel, and improve the operational efficiency of power enterprises.
For more details about the equipment, please consult Ms. Li from Teluck, mobile phone number: 13682351635 (WeChat is the same number, you can add it)
Customized products, the quoted price is the reference interval price at the time of market release, the actual price is subject to negotiation.
VI. Precautions:
1. Pay attention to avoiding the device from falling on the ground or being subjected to strong impacts from other objects;
2. Pay attention to avoiding strong external impacts on the solar panel to prevent damage to the solar panel;
3. When installing, try to make the solar panel face the direction of sunlight;
4. When installing the device, turn off the power switch, and turn on the power switch after installation is completed;
5. It is strictly forbidden to disassemble the structure or circuit board without permission. Unauthorized disassembly of the device will void the warranty.
Please retain the source link when copying:http://www.fxbcomic.com/show/38583.html