China Overhead Transmission Line Ice Coating Monitoring System - China Supplier
China Overhead Transmission Line Ice Coating Monitoring System - China Supplier China Overhead Transmission Line Ice Coating Monitoring System - China Supplier China Overhead Transmission Line Ice Coating Monitoring System - China Supplier China Overhead Transmission Line Ice Coating Monitoring System - China Supplier China Overhead Transmission Line Ice Coating Monitoring System - China Supplier

Overhead Transmission Line Ice Coating Monitoring System

¥80000
Instruments & Meters/Measurement Standards/Electromagnetic Metrology Standards


Contact Info
  • Building C-9, Floor C, Precision达 Industrial Park, No.39 Qingfeng Avenue, Longgang Sub-district, Longgang District, Shenzhen City, 518116
  • 李女士
  • 13682351635
  • 1920671927@qq.com

Product Alias: Transmission Line Ice Cover Monitoring System, Line Ice Cover Image Monitoring Equipment, Conductor Contact Ice Cover Monitoring Device

Product Model: TLKS-PMG-FB100

Overhead Transmission Line Ice Cover Monitoring System for Power Grid

I. Product Description:

Overhead Transmission Line Ice Cover Monitoring System for Power Grid, as an important tool for intelligent operation and maintenance in the power industry, is specially designed for the safety monitoring of transmission lines and iron towers. This device captures the ice cover conditions on iron towers and lines in real time, and uses precise status judgment technology to accurately assess the severity of ice cover, providing timely and reliable decision support for the management and maintenance personnel of power facilities.

II. Working Principle:

Overhead Transmission Line Ice Cover Monitoring System for Power Grid integrates multiple advanced technologies such as remote data acquisition, digital processing, wireless transmission and intelligent analysis, realizing comprehensive, real-time and precise monitoring of ice cover conditions on transmission lines and iron towers. This device not only captures images and videos of transmission lines and iron towers, but also monitors real-time parameters such as conductor tension, inclination angle and micro-meteorological parameters (such as temperature, humidity, wind speed), and collects key data continuously through a remote data collector. The system has built-in advanced digital compression coding technology to efficiently compress the original data. Then, these encoded data are transmitted to the remote data monitoring center in the form of IP packets through wireless transmission modules such as 4G/3G/GPRS/CDMA. At the monitoring center, maintenance personnel conduct in-depth analysis of the received data and compare it with historical data and preset safety thresholds. This helps maintenance personnel fully understand the real-time status of transmission lines, and accurately assess the development trend of ice cover and its potential impact on power grid operation. Once abnormal data is detected or early warning conditions are triggered, the system will immediately activate the emergency response process and notify on-site maintenance personnel to adjust the line operation status in time, so as to ensure the safe and stable operation of transmission lines under extreme weather conditions.

III. Product Functions:

1. It has the functions of managing and self-checking its own working status, including acquisition, storage, processing, communication, etc.

2. When it is judged that the device has a malfunction, it can take corresponding measures to restore the normal operation status of the device.

3. It has functions of identity authentication and remote program update, with a complete update mechanism and methods.

4. It has the ability to modify parameters such as acquisition frequency, sampling time interval, and network adapter address according to remote instructions.

5. It has the ability to dynamically respond to remote time query settings, data requests, reset and other instructions.

7. It can enter the remote debugging mode according to remote instructions and output relevant debugging information.

8. It is equipped with a security chip, which can encrypt data and access provincial company platforms.

IV. Technical Parameters:

1. Power supply mode: Solar energy + battery

2. Communication requirements: Supports wireless network communication, and operators can be selected according to on-site conditions.

3. Working voltage: DC12V

4. Standby time: >30 days

5. Back-end software platform:

. Supports access to provincial and municipal bureau PMS systems

7. PG client/mobile client can view monitoring data in real time

8. Remote update, configuration and debugging of front-end device parameters

V. Summary:

In summary, Overhead Transmission Line Ice Cover Monitoring System for Power Grid, with its efficient data acquisition, processing and transmission capabilities, as well as intelligent analysis and early warning functions, provides strong technical support for the operation and maintenance management of the power industry. Its application not only enhances the disaster prevention and mitigation capabilities of the power grid, but also reduces operation and maintenance costs, ensuring the continuity and reliability of power supply.

We look forward to cooperating with you to jointly explore the market and provide high-quality products and services for customers.

For more details about the equipment, please call Ms. Li from Shenzhen Telikang Technology Co., Ltd.

Contact number: 13682351635 (WeChat same number, can be added) QQ: 1920671927

Landline number: 0755-29500762

Customized products, the quoted price is a reference interval price when released in the current market, and the actual price is subject to negotiation.

VI. Notes:

1. Please operate with caution to prevent the device from falling accidentally or being subjected to strong collisions.

2. To ensure the normal operation of the solar panel, please avoid subjecting it to strong external impacts to prevent damage.

3. During installation, please try to ensure that the solar panel faces the direction of sunlight to maximize its energy collection efficiency.

4. Before installing the device, please make sure the power switch is turned off. After installation is complete, turn on the power switch safely.

5. Unauthorized disassembly of the device structure or circuit board is strictly prohibited. Unauthorized disassembly will void the warranty.


Instruments & Meters/Measurement Standards/Electromagnetic Metrology Standards