China Explosion-proof bromine gas alarm - China Supplier
China Explosion-proof bromine gas alarm - China Supplier China Explosion-proof bromine gas alarm - China Supplier China Explosion-proof bromine gas alarm - China Supplier China Explosion-proof bromine gas alarm - China Supplier China Explosion-proof bromine gas alarm - China Supplier

Explosion-proof bromine gas alarm

¥1600
Instruments & Meters/Other Instruments/Gas Alarms & Detectors


Contact Info
  • Room 405, 4th Floor, Xijun Building, No.4 Shangxue Road, Xinxue Community, Bantian Subdistrict, Longgang District, Shenzhen City,
  • 陈工
  • 19926530652
  • 2183550010@qq.com

Introduction
Gas detectors are flameproof safety devices that can quickly, reliably, and stably continuously detect gas concentrations in industrial production. When the detected gas concentration reaches the preset alarm value of the gas detector, the detector will trigger an alarm and drive external devices to remind on-site staff to take necessary protective measures, preventing gas-induced combustion accidents.
Working principle of gas detectors: The detector installed on-site operates on power supply. When a gas leak occurs, the sensor converts the detected leak amount into a corresponding voltage signal for output. After the voltage signal is processed by the detector, the data is uploaded and displayed on the screen. When the concentration reaches the set action value, the detector triggers an alarm and drives external devices.
A gas detector is a fixed instrument that can continuously detect oxygen concentration or toxic, harmful, flammable, and explosive gas concentrations in the working environment.
Gas detectors adopt a diffusion method, which converts the gas concentration signal at the monitoring point into an electrical signal in real time. After the signal is amplified, it undergoes A/D sampling, temperature compensation, and intelligent calculation by the CPU, then the measurement result is processed. If the measured value exceeds the set alarm concentration value, an alarm signal will be issued.
Gas detectors feature a dual-chamber design, dedicated imported sensors, and the sensors adopt a modular design, making calibration and adjustment more convenient. They have superior performance, high stability, can output multiple sets of signals, and are easy to install and maintain, meeting the high reliability requirements of industrial on-site equipment.

Features
Ingenious structural design, extremely easy to install;
Upper and lower alarm points can be set arbitrarily within the full range;
Flameproof design, can be used in hazardous areas 1 and 2 under factory conditions;
Gas detectors can be optionally equipped with a liquid crystal concentration display, showing the concentration in real time on-site;
Gas detectors can be optionally equipped with dedicated flameproof audible and visual alarms to achieve on-site audible and visual alarms;
Meet any range requirements between 1-99999 and all gas detection needs of customers;
Two sets of normally open passive contact outputs, used for controlling AC contactors of fans or solenoid valves;
Exquisite power supply design, pure SMT component patch process, ensuring stable product performance;
The sensor uses imported gas-sensitive elements, with high precision, long lifespan, low zero drift, fast response time, can work continuously for a long time, has a small body, is easy to operate, and has good anti-poisoning performance;
The alarm point adjustment, zero point adjustment, and target point calibration of the transmitter can be performed without opening the cover via the controller;
Suitable for dozens of gas detections, and can display gas names; Gas unit names: ppm, LEL%, VOL%, mg/m³;
International standard (4~20)mA signal can be directly connected to the factory DCS system, and RS485 digital signal is connected to the factory host computer

Accuracy

±2%FS (high-precision type), ±5%FS (standard type)

Weight

1.5Kg

Warranty Period

12 months

Output Signal

4-20mA/RS485/Passive Switch Quantity

Interlocking Equipment

Fans, Solenoid Valves, Fire Protection Systems, etc. (24VDC/1A)

Explosion-proof Type

Intrinsically Safe Type

Explosion-proof Mark

Ex d II C T6 Gb

Working Voltage

DC12-24V±1%

Dimension Specification

140mm (length) × 164mm (width) × 75mm (height)

Housing Material

Stainless Steel/Aluminum Alloy

Sampling Method

Diffusion Type or Pipeline Type

Temperature Class

-40℃~+65℃ (standard type)/-40℃~+70℃ (extreme type)

Humidity Class

15~95% RH (no condensation)

Ambient Pressure

86kPa ~106kPa

Service Life

More than 3 years

Instruments & Meters/Other Instruments/Gas Alarms & Detectors
About Toocle.com -  Toocle Partnership -  Toocle Services -  Toocle Agents
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192