Endress+Hauser (E+H) PMC131-A11F1D24 Ceramic Pressure Transmitter 0-40kPa

Pressure Transmitter PMC131-A11F1D24

Product Description

Ceramic measuring element pressure sensor

Can measure gauge pressure and absolute pressure

High overload resistance

Application

Suitable for measuring absolute pressure and gauge pressure of gases, steam and liquids.

Features and Advantages

· Safety of measurement with ceramic measuring element

· High stability

· Easy installation

Measuring System

· Cerabar T pressure sensor with 4...20mA output

· Power supply voltage: 11-30V, e.g., using power supply units RN221, NX9120 or NX9121 provided by E+H

Manufacturer: E+H

Instrument Name: Pressure Transmitter PMC131-A11F1D24

Application

Measure gauge pressure and absolute pressure of gases, steam and liquids

Operation and System Design

Measuring Principle: The measured pressure causes a small deformation on the ceramic diaphragm of the sensor. Electrodes on the ceramic sensor measure the resulting change in capacitance proportional to the pressure.

Modularity: The pressure sensing element can be connected to the transmitter power supply via optional DIN43650 A/ISO4400 plug or cable gland.

Input

Measured Variable: Gauge pressure or absolute pressure

Measuring Range: Max. 40bar (see selection table)

Output

Output Signal: 4⋯20mA

Load: R(Ω) ≤ (U-11V)/0.02A

Accuracy

Reference Conditions: Complies with DIN IEC 770

Rise Time: 20ms (T time)

Measurement Deviation (including hysteresis and repeatability): 0.5% FS

Nominal Range Ambient Temperature Effect: Zero signal change between -20⋯+85℃ (-4...+185°F), typical: 1.5%; Range change between -20⋯+85℃ (-4...+185°F), typical: 0.8%; (0.4bar⋯40bar), typical: 1.0% (0.1bar)

Long-Term Stability: 0.15%/year

Pressure Transmitter PMC131-A11F1D24

Electrical Connection:

A1   Plug connector ISO4400 M16, IP65 NEMA4X

Process Connection:

1   Thread ISO228 G1/2, 304

Sensor Seal:

F   FKM Viton

Additional Options:

1   Basic Type

Measuring Range; Sensor Overload Limit:

D24   0...400mbar/40kPa abs; 8bar/800kPa