Power line sag monitoring device
Contact Info
- Building C-9, Floor C, Precision达 Industrial Park, No.39 Qingfeng Avenue, Longgang Sub-district, Longgang District, Shenzhen City, 518116
- 小李
- 18820479231
- 2512646832@qq.com
Alternative product names: Power line sag monitoring equipment, conductor sag monitoring system, power grid line sag monitoring device, high-voltage line sag monitoring device
1.Introduction
With the continuous expansion of power networks, transmission lines serve as a key component for energy transmission and are long-term affected by complex environments. High temperatures increase conductor sag, which can easily lead to accidents, and severe weather can also cause sag anomalies, which traditional patrols struggle to address. Failures caused by sag issues will interrupt power supply and result in losses, so the urgent need to introduce an intelligent monitoring device to ensure power grid safety has become a pressing requirement.
2.Overview
The advanced equipment integrates intelligent monitoring and efficient early warning. It combines cutting-edge technology to continuously and accurately monitor the sag status of transmission line conductors, capture subtle sag changes in a timely manner, provide reliable data support for power grid operation and maintenance personnel, effectively prevent various safety accidents caused by sag anomalies, and build a solid technical defense line for the stable operation of the power system.
3.Working Principle
The power grid line sag monitoring device uses a sag sensor to real-timely and accurately monitor the minimum distance between the conductor and the ground, the horizontal angle of the conductor at the outlet of the clamp, and the sag status of the conductor. Once a sag anomaly is detected, the system will immediately send early warning information via 4G/WIFI optical fiber network to remind managers to take timely measures and effectively prevent potential safety risks.
4.Core Functions
1.High-precision monitoring technology: Adopts advanced sag sensors to real-timely and accurately monitor the minimum distance between the conductor and the ground, the horizontal angle of the conductor at the outlet of the clamp, and the sag status of the conductor, ensuring data accuracy.
2.Automated data collection: The system has an internal timing collection mechanism, with a default setting of collecting data automatically every 30 minutes, and supports remote command control to achieve real-time data acquisition and analysis.
3.Intelligent early warning system: Once a sag anomaly is detected, the system will immediately send early warning information through multiple channels to remind managers to take timely measures and effectively prevent potential safety risks.
4.Battery intelligent management: Integrates battery voltage monitoring function to ensure the device can operate stably in complex environments and extend its service life.
5.Data secure transmission: Adopts advanced encryption technology to ensure the security of data transmission, and seamlessly connects with provincial company platforms to achieve data sharing and efficient utilization.
5.Technical Parameters
1.Power supply mode: Solar energy + lithium battery
2.Communication mode: Supports adaptive access of China Telecom, China Unicom and China Mobile, and operators can be selected according to on-site conditions
3.Working voltage: DC12V
4.Working current: <50mA
5.Standby duration: >30 days
6.Distance measurement range: 0m-200m
6.Installation Method
The design of the TLKS-PMG-HC power grid line sag monitoring device fully considers installation convenience and flexibility, making it suitable for multiple monitoring scenarios:
1.Jumper sag monitoring: The sensor is directly fixed on the jumper to accurately capture sag changes and ensure monitoring accuracy.
2.Insulator sag monitoring: The sensor can be installed at the upper and lower ends of the insulator string to achieve full-coverage monitoring without dead angles.
3.Inter-phase sag monitoring within a span: Install the sag monitoring device between the two conductors to be monitored to achieve real-time monitoring of inter-phase sag and improve power grid safety.
7.Conclusion
On the journey of the power industry developing towards intelligence and high efficiency, Teluck has always been at the forefront, driving development through innovation. The TLKS-PMG-HC power grid line sag monitoring device, with its leading technology, excellent performance and perfect services, has become a reliable assistant for power grid safety operation and maintenance. In the future, we will continue to deepen our work in the power technology field, continuously optimize products and services, inject strong impetus into the high-quality development of the power industry, and safeguard the brightness and tranquility of thousands of households. Products can be customized. The quoted price is a reference price as of the current release. For the actual price, please contact us for a quotation. For more product information, please feel free to contact Teluck Technology Manager Li 1/8/8/2/0/4/7/9/2/3/1 WeChat and QQ are the same