The YJP series Pharmaceutical Stability Test Chambers are mainly used by pharmaceutical enterprises for testing drug aging and accelerated stability, and are also suitable for cell and tissue culture, seed germination, seedling cultivation, insect and small animal rearing, microbial and antibiotic culture and preservation, as well as performance testing of wood and building materials. They are ideal devices, especially applicable as constant temperature and humidity experimental culture equipment for production and scientific research in fields such as bioengineering, medical research, agricultural science, aquatic products, and animal husbandry. Adopting microcomputer technology with programmable control mode, by setting multiple parameters including temperature, humidity, light, and time, it can operate in day/night cycles to simulate natural climate, with excellent control performance and anti-interference ability, meeting the requirements of various drug-related tests, animal and plant production, and various biological preservation needs. With fully automatic microcomputer control and touch switches, it is easy to operate. The programmable control mode allows separate setting of temperature, humidity (adjustable), light, and time for both day and night. It has a power failure memory function, an intelligent constant temperature control system with fast response and high temperature control accuracy, and adopts an internal dehumidification method for reliable performance. The duct-type ventilation provides a gentle air flow in the chamber, ensuring uniform temperature and humidity.
I. Core Components
1. 7-inch large touch screen display, making all parameters clear at a glance
2. PT100 temperature sensor
3. Humidity sensor
4. Adopts a variable frequency compressor unit, with good cooling effect and power saving
5. Built-in humidifier
II. Main Structure
1. Outer box: Made of cold-rolled steel plate, with high-temperature paint to enhance corrosion resistance
2. Insulation layer: High-pressure polyurethane foam
3. Inner wall: SUS304 brushed stainless steel
4. Shelves: Processed from SUS304 stainless steel bars
5. Door lock: Equipped with a key lock for effective management
5. Verification hole: φ30mm
6. Humanized design: 4 caster wheels with level adjustment, movable and lockable, each equipped with one interior light and one UV lamp
7. Door seal: Double-layer door seal design, locking temperature and humidity with minimal loss
8. Observation window: Double-layer hollow glass
III. Functional Features
1. Sturdy and practical structure: The insulation layer is 80mm thick polyurethane foam, with excellent heat and moisture preservation performance. Fan: Waterproof fan, longer service life
2. Environmental control system Air flow mode: Forced vertical convection, uniform overall air duct Temperature control mode: Electric heating system, variable frequency compressor cooling system Humidity control mode: Self-developed electric steam humidification
3. Energy saving and environmental protection Overall cold insulation design of the cabinet, low energy consumption R134A environmentally friendly refrigerant Low noise, less vibration
4. Control system & data acquisition Balanced control mode, more precise temperature and humidity control Preset automatic startup function 7-inch large touch screen display, making all parameters clear at a glance, can set 30 segments and 99 cycles, time can be set up to 9999 hours or 9999 minutes Dual data acquisition system, built-in pin-type printer, USB data storage, ensuring real and valid data Paperless recorder, records the operating values of the equipment, displays curves for intuitive viewing, data can be exported, with three-level permission settings. Remote alarm function for abnormal temperature and humidity, same-screen function for mobile phone and test chamber controller, both mobile phone and controller can operate independently, allowing users to remotely view and operate the test chamber in real time, with permission setting and allocation function.
5. Protection system Compressor overload protection Independent chamber over-temperature protection Humidification system water shortage protection Humidification water shortage alarm system
IV. Technical Parameters of Pharmaceutical Stability Test Chambers
Model |
YJP-100 |
YJP-160 |
YJP-250 |
YJP-500 |
YJP-1000 |
|
Volume |
100L |
160L |
250L |
500L |
1000L |
|
Refrigeration system |
Air-cooled |
|||||
Ambient temperature |
5-35℃ |
|||||
Temperature range |
With light: 10-60℃; Without light: 5-60℃ |
|||||
Light intensity |
0-6000LX adjustable; LED light source |
|||||
Humidity control range |
40-95%RH (When temperature is 40℃, humidity can reach 20-95%RH, sustainable for 2 hours) |
|||||
Humidity fluctuation |
±5%RH |
|||||
Temperature resolution of instrument |
0.1℃ |
|||||
Temperature uniformity |
±2℃ |
|||||
Temperature fluctuation |
±1℃ |
|||||
Power supply |
~220V 50Hz |
|||||
Power |
1200W |
1200W |
1800W |
2500W |
3800W |
|
Inner chamber dimensions (mm) |
450×380×580 |
500×400×800 |
530×540×900 |
680×630×1150 |
1040×610×1645 |
|
External dimensions (mm) |
606×685×1300 |
660×650×1430 |
640×740×1650 |
780×840×1800 |
1580×820×1880 |
|
Shelves (units) |
2 |
3 |
3 |
3 |
5 |
|
Remarks |
Special specifications and requirements can be customized |
|||||
| Instruments & Meters/Laboratory Instrument Devices/Corrosion Test Chambers | |