Partlama garşy C8H10 gaz duýgusy
Contact Info
- Salgysy:405-nji boýun, Şim Jum köşgesi, 4-nji ýoly, Ýanghy köşegesi, Bapty şaýary, Lunqan welaýaty, Şençej şäheri, Poçta indeksi:
- Habarlaşmak: 陈工
- Tel:19926530652
- E-poçta:2183550010@qq.com
Beýleki önümler
Giriş Gas alarm is a flameproof safety device that can quickly, reliably, stably and continuously detect gas concentration in industrial production. When the detected gas concentration reaches the preset alarm value of the gas alarm, the alarm will sound and drive external equipment to remind on-site staff to take necessary protective measures, preventing gas-induced combustion accidents. Working principle of gas alarm: The alarm installed on site is powered on and works. When gas leakage occurs, the sensor converts the detected leakage amount into a corresponding voltage signal for output. After the voltage signal is processed by the alarm, the data is uploaded and displayed on the screen. When the concentration reaches the set action value, the alarm sounds and drives external equipment. Gas alarm is a fixed instrument that can continuously detect oxygen concentration or toxic, harmful, flammable and explosive gas concentration in the working environment. The gas alarm adopts diffusion method to convert the gas concentration signal at the monitoring point into electrical signal in real time. After the signal is amplified, it is processed by the CPU through AD sampling, temperature compensation and intelligent calculation. If the measured value exceeds the set alarm concentration value, an alarm signal will be sent out. The gas alarm adopts a dual-chamber design, special imported sensor, and the sensor adopts modular design, making calibration and verification more convenient. It has superior performance, high stability, can output multiple sets of signals, and is convenient for installation and maintenance, meeting the high reliability requirements of industrial on-site equipment. Özellikler Clever structural design, extremely simple installation; Upper and lower alarm points can be set arbitrarily within the full range; Flameproof design, can be used in dangerous areas 1 and 2 of factory conditions Gas alarm can be equipped with LCD concentration display, real-time on-site concentration display Gas alarm can be equipped with special flameproof acoustic-optic alarm to realize on-site acoustic-optic alarm Meet customers' any range between 1-99999 and all gas detection requirements; Two sets of normally open passive contact outputs, used to control the AC contactor of the fan or solenoid valve Ingenious power supply design, pure SMT component patch process, making the product performance stable; The sensor uses imported gas-sensitive components, with high precision, long service life, small zero drift, fast response time, long-term continuous operation, small body, convenient operation and good anti-poisoning performance The alarm point adjustment, zero adjustment and target point calibration of the transmitter can be carried out through the controller without opening the cover Suitable for dozens of gas detections, and can display gas names; gas unit names: ppm, LEL%, VOL%, mg/m3 International standard (4~20)mA signal can be directly connected to the factory DCS system, RS485 digital signal is connected to the factory upper computer
|
| Senagat kategoriýasy: | Instruments & Meters/Other Instruments/Gas Alarms & Detectors |
|---|---|
| Önüm kategoriýasy: | |
| Brend: | |
| Aýratynlyklary: | |
| Ambar: | |
| Gelip çykyşy: |