Air Conditioning Inspection
Contact Info
- Add:广东省广州市天河区珠吉路号之二四楼B4858, Zip: 510000
- Contact: 蹇友华
- Tel:13124986688
- Email:1580341840@qq.com
Other Products
I. Inspection Items
1. Packaging
Barcode scanning
Drop test
2. Function
Installation and online testing
Remote control distance/angle test
Remote control drop test
Full function test
Basic function test of indoor unit
Basic function test of outdoor unit
Refrigerant leak test
Filling weight measurement test
3. Safety
CDF verification check
Wipe test
Structure inspection
Low voltage startup test
Four safety tests
4. Enthalpy difference
Heating capacity and heating power consumption
Cooling capacity and cooling power consumption
Heating efficiency COP and cooling efficiency EER
Circulating air volume
Noise
II. Performance Standards
1. Performance Terminology
Item | Meaning | Remarks |
Standard conditions | Cooling: Indoor dry 27°C/wet 19°C, Outdoor dry 35°C/wet 24°C Heating: Indoor 20°C, Outdoor 7°C | |
Standard air | Dry air at 20°C, 1 standard atmosphere, density 1.20 kg/m³ | |
Circulating air volume | Air volume passing through the indoor unit evaporator per unit time (m³/h) | Enthalpy difference method Wind speed × air outlet area |
Ventilation air volume | Fresh air volume entering indoors from outdoors per unit time (m³/h) | Ventilation capacity Wind speed × air outlet area |
Enthalpy difference method | Measure supply/return air parameters, circulating air volume Product of air volume and supply/return air enthalpy difference, i.e., heating/cooling power | Measures all performance parameters of air conditioner except noise |
Heating power consumption | Input power (W) during heating operation under rated conditions | Input power |
Heating capacity | Heating output per unit time during heating operation under rated conditions (W) | Heating power |
COP | COP = Heating power / Heating input power, i.e., heating efficiency | Coefficient of Performance |
Cooling power consumption | Input power (W) during cooling operation under rated conditions | Input power |
Cooling capacity | Cooling output per unit time during cooling operation under rated conditions (W) | Cooling power |
EER | EER = Cooling power / Cooling input power, i.e., cooling efficiency | Energy Efficiency Ratio |
Dehumidification capacity | Ability to remove moisture from indoors per unit time |
2. Standard Items (Cooling Aspect)
Item | Standard Requirement | Method |
Heating power | >95% of rated value | Enthalpy difference test |
Heating input power | <110% of rated value | |
COP | >90% of rated value, and the rated value must meet energy consumption requirements | |
Cooling power | >95% of rated value | |
Cooling input power | <110% of rated value | |
EER | >90% of rated value, and the rated value must meet energy consumption requirements | |
Electric heating input power | Less than 200W: ±10% Greater than 200W: -10%/+5% or 20W (whichever is larger) | |
Dehumidification test | / | Standard conditions Dehumidification operation for one hour |
Freezing check | Conditions: Air conditioner set to the state most prone to frosting, indoor dry 25°C/wet 11°C | |
1. Indoor unit evaporator, frosting area <50% | Run for 4 hours, check frosting area | |
2. No dripping from indoor unit, air supply should not blow out water | Cover the return air outlet, run for 6 hours, Stop completely for defrosting, then maximum wind speed for 5 minutes | |
Condensation check Drainage check | Conditions: Air conditioner set to the state most prone to condensation, both sides dry 27°C/wet 24°C | |
1. Condensation on indoor unit surface should not drip Air supply should not carry water droplets | Cooling operation for 4 hours | |
2. Can automatically discharge condensate water Water should not blow out or overflow | Fill the water tray with water, run cooling operation | |
Defrost test | Conditions: Air conditioner set to the state most prone to frosting, indoor dry 20°C/wet 12°C, outdoor dry 1°C/wet 1°C | |
1. Defrost time <20% of operation time 2. Frost layer on outdoor unit should melt away | ||
Item | Method National Standard GB7725 | US Standard RAC-1 (Standard requirement: Can operate normally, components not damaged, overload protection does not trip) |
Maximum cooling operation | Conditions: Air conditioner set to maximum cooling state, air damper closed, 90% and 110% voltage | |
T1 Indoor dry 32°C/wet 23°C Outdoor dry 43°C/wet 26°C T2 Indoor dry 27°C/wet 19°C Outdoor dry 35°C/wet 24°C T3 Indoor dry 32°C/wet 23°C Outdoor dry 52°C/wet 31°C | Indoor dry 32°C/wet 23°C Outdoor dry 43°C/wet 26°C | |
Run 3 hours, stop 3 minutes, run 3 hours again | Run 2H, stop 3 min, run 1H | |
Minimum cooling operation | Conditions: Air conditioner set to the state most prone to frosting, both sides dry 21°C/wet 15°C | |
Air damper closed, minimum cooling operation for 4 hours | Not required | |
Maximum heating operation | Conditions: Air conditioner set to maximum cooling state, air damper closed, 90% and 110% voltage | |
Indoor 27°C, Outdoor dry 24°C/wet 18°C | ||
Run 3 hours, stop 3 minutes, run 3 hours again | Run 2H, stop 3 min, run 1H | |
Minimum heating operation | Conditions: Indoor dry 20°C/wet (none), Outdoor dry -5°C/wet -6°C | |
Air damper closed, minimum heating operation for 4 hours | Not required | |
Item | Standard Requirement | Method |
Enthalpy difference test | Test: Inlet air parameters (temperature/humidity) Return air parameters (temperature/humidity) Circulating wind speed/air outlet area Calculate: Cooling power (cooling capacity) Heating power (heating capacity) Calculate: Heating efficiency COP = Heating capacity / Input power Cooling efficiency EER = Cooling capacity / Input power | Test method See 3. Test Method for details Energy efficiency grade See table below |
Noise test | Rated value < standard limit Measured value < rated value + 3 dB | |
Leak test | <2 g/year (Factory requirement for R410, etc. <0.5 g/year) | |
Coating cross-cut test | 1. Cut 4 lines through the coating to the base metal, forming 9 small 1mm x 1mm squares 2. Brush with a 25-35mm wide paint brush to check if the coating peels off from the squares 3. Maximum allowable total area of peeling squares is 3 | |
Energy efficiency grade EER GB19021.3
Energy efficiency label GB19021.3
Noise limit GB19606
3. Test Methods
1) Leak test
Instrument: Multi-refrigerant halogen leak detector
Location: Various pipeline welding points
Leakage value: ≤2 g/year
2) Safety test
Electrical strength 1800 V 3s no breakdown
Leakage current ≤0.75 mA
Ground resistance ≤0.5 ohm
Insulation resistance ≥2 M ohm
Startup voltage 85% of rated voltage
3) Noise test
Sound level meter:
Slow mode, A-weighting
Air conditioner runs for 30 minutes,
Set to maximum noise state
Pointer fluctuation less than ±3dB, take average value
(1) Noise limit GB19606
(2) Noise instrument
(3) Noise spectrum
(4) Anechoic chamber
(5) Noise concept
(6) Several typical envelope surfaces
4) Enthalpy difference test
Under standard conditions, test the changes in air volume and air outlet temperature over a certain period,
Calculate the air conditioner's cooling/heating power
Cooling capacity
Cooling input power P
COP
Heating capacity
Heating input power
EER
Circulating air volume
EER = Heating capacity / Heating input power
(1) Enthalpy difference test
(2)
Defects and Cases
1. Nameplate corners curled, found during inspection, curled nameplates easily stick to plastic packaging bags and tear off when opening the package
2. Design temperature (61-86°F) and actual adjustable temperature (64-86°F) inconsistent
3. °C/°F temperature conversion, product and manual lack instructions on how to convert
4. Button failure, disassembly inspection found microswitch button height inconsistent with design height
5. Panel corner cracked
6. Seal strip blocking curtain track
7. Temperature sensor wire burned
8. Temperature sensor head loose and displaced
9. Trim strip buckle broken
10. Injection port not cleaned