China Far-infrared filter with high cut-off depth precision coating for 8-14μm temperature measurement imaging window - China Supplier China Far-infrared filter with high cut-off depth precision coating for 8-14μm temperature measurement imaging window - China Supplier China Far-infrared filter with high cut-off depth precision coating for 8-14μm temperature measurement imaging window - China Supplier China Far-infrared filter with high cut-off depth precision coating for 8-14μm temperature measurement imaging window - China Supplier China Far-infrared filter with high cut-off depth precision coating for 8-14μm temperature measurement imaging window - China Supplier

Far-infrared filter with high cut-off depth precision coating for 8-14μm temperature measurement imaging window

Price:460
Industry Category: Measurement-Analysis-Instruments
Product Category:
Brand: 新兆光电
Spec: 可打样


Contact Info
  • Add:深圳市坪山区锦绣中路19号美讯科技园A栋8楼, Zip:
  • Contact: 范小姐
  • Tel:0755-85209446
  • Email:

Other Products

Description
Additional Information

Far-infrared (FIR) filters refer to optical filters operating in the wavelength range of 6–14 μm (sometimes defined as 8–14 μm). They are specifically designed to selectively transmit thermal radiation emitted by room-temperature or high-temperature objects such as the human body, engine exhaust, and industrial gases, while deeply blocking visible and near-to-mid-infrared wavelengths.

  1. Optical Characteristics
    • Typical passbands: 8–14 μm (for human body temperature measurement), 9.5–10.5 μm (CO₂ laser safety window), 10.6 μm single-line narrowband (for CO₂ laser online detection), etc.
    • Peak transmittance: ≥80% with single-side AR coating, can reach ≥92% with double-side coating.
    • Blocking depth: average out-of-band transmittance < 0.1% (OD≥3), meeting the requirements of high-sensitivity thermal imaging and gas analysis.
    • Spectral steepness: passband-to-blocking transition region ≤ 1% bandwidth, ensuring signal purity.

  2. Common Substrates and Coating Systems
    • Ge: High refractive index (n≈4.0@10 μm), suitable for narrowband filters; requires double-side AR coating to prevent reflection; good mechanical strength, preferred for thermal imagers.
    • ZnSe: Transmits from 0.5–20 μm, extremely low absorption (<0.0005 cm⁻¹@10.6 μm), resistant to high-power CO₂ lasers; low hardness requires scratch protection.
    • ZnS (multispectral grade): 0.4–14 μm transmission, wear-resistant and acid/alkali-resistant, suitable for outdoor windows.
    • Chalcogenide glass: 1–14 μm transmission, moldable into aspheric shapes, low cost, widely used in high-volume thermometer windows.
    • Coating technology: multilayer Ge/SiO₂+ZnS alternating hard coatings; surfaces can be further coated with diamond-like carbon (DLC) or PE scattering layers for moisture resistance and laser damage protection.