A solid-state decoupler is a device used in cathodic protection systems to safely and effectively control the impact of AC fault currents or lightning currents on buried pipelines. The following sections provide a detailed introduction from the perspectives of its working principles, technical parameters, performance advantages, and application scope:
Working Principles AC Bypass Principle: Utilizing the characteristics of capacitors having low impedance to AC signals and inductors offering resistance to AC currents while filtering out specific frequency AC signals, a filter circuit composed of capacitors and inductors is designed to bypass the induced AC currents on the pipeline to the ground, eliminating the impact of AC interference on the cathodic protection system.
Overvoltage Protection Principle: Internally, nonlinear resistive components such as metal oxide varistors (MOVs) are typically employed. Under normal operating voltage, their resistance is extremely high, allowing almost no current to pass through. When subjected to overvoltage impacts such as lightning strikes or surges, their resistance rapidly decreases, entering a low-resistance state, thereby quickly diverting the large current generated by the overvoltage to the ground and limiting the voltage amplitude on the pipeline.
DC Decoupling Principle: Unidirectional conduction components, such as diodes, are used. When the cathodic protection current flows in the normal direction, the unidirectional conduction component is in a conducting state, allowing the cathodic protection current to pass through. When external DC stray currents attempt to enter the pipeline, the reverse blocking characteristic of the unidirectional conduction component prevents the DC stray currents from entering. Additionally, DC decoupling can be achieved by monitoring and controlling the potential difference between the pipeline and the ground. When abnormal changes in pipeline potential are detected, the decoupler adjusts internal circuit parameters to regulate the current flow between the pipeline and the ground, restoring the pipeline potential to the normal cathodic protection potential range.
Technical Parameters 1 DC Isolation Voltage: Typically -2V/+2V, which is the threshold for determining whether to switch to short-circuit mode to provide overvoltage protection.
Impulse Current Capacity: Generally expressed as the current value under a 4/10µs waveform, such as 100 kA, reflecting the decoupler's tolerance capability when subjected to lightning strikes or AC fault currents.
Steady-State AC Current: For example, 45 A, refers to the steady-state AC current value that the decoupler can conduct under normal operating conditions.
Leakage Current: Required to be ≤1 mA, reflecting the performance of the decoupler in isolating DC currents. The smaller the leakage current, the better the isolation effect on DC currents.
Fault Current: For example, ≥3500 A (AC-rms / power frequency / 30 cycles), indicates the AC root mean square current value that the decoupler can withstand under fault conditions.
Operating Temperature: Typically -45°C to +60°C, reflecting the temperature range within which the decoupler can operate normally.
Protection Rating: Usually IP65, indicating that the decoupler has excellent dust and water resistance.
Performance Advantages High Reliability: Utilizes advanced solid-state components with no mechanical moving parts, reducing the risk of failures caused by mechanical wear, poor contact, and other issues. It can operate stably for extended periods under harsh environmental conditions.
Rapid Response: Can react to stray current interference within nanoseconds, quickly activating protection mechanisms to effectively prevent sudden corrosion damage caused by stray currents.
Strong Overvoltage Protection Capability: Capable of withstanding high-amplitude surge voltages. Through built-in high-performance varistors and other overvoltage protection components, it limits overvoltages to safe ranges, protecting other equipment in the cathodic protection system from damage.
Data Monitoring and Communication Functions: Intelligent solid-state decouplers are equipped with various sensors to monitor parameters such as current, voltage, and ambient temperature in real time. Data is transmitted to remote monitoring centers via wireless communication modules, facilitating intelligent remote management by personnel.
Application Scope Pipeline Protection: Used for decoupling pipeline potential gradient mats (grounding mats) and in areas such as buried long-distance pipelines, high-voltage transmission lines, electrified railways, or communication towers to reduce the impact of AC-induced voltages and stray currents, protecting pipelines from corrosion.
Equipment Protection: Provides overvoltage protection for equipment against AC faults, lightning, and switching transients, such as insulated joints and insulated flanges.
Power Systems: Used around high-voltage transmission lines and electrified railways to reduce stray current interference with buried pipelines. It can also protect equipment such as substations and power plants from AC-induced voltages and stray currents.
Communication Systems: Prevents stray current interference with communication lines, ensuring clear and stable transmission of communication signals.
Other Fields: Can also be used in circuit board design and debugging to isolate high-frequency noise in power supplies, as well as in scenarios such as decoupling between different metals.
| Industry Category | Electrical-Equipment-Supplies |
|---|---|
| Product Category | |
| Brand: | 焦作市环隆防腐技术开发有限公司 |
| Spec: | |
| Stock: | |
| Origin: | China / Henan / Jiaozuoshi |