China Stainless Steel Low Resistance Backflow Preventer HX BXFM-16P - China Supplier China Stainless Steel Low Resistance Backflow Preventer HX BXFM-16P - China Supplier China Stainless Steel Low Resistance Backflow Preventer HX BXFM-16P - China Supplier China Stainless Steel Low Resistance Backflow Preventer HX BXFM-16P - China Supplier China Stainless Steel Low Resistance Backflow Preventer HX BXFM-16P - China Supplier

Stainless Steel Low Resistance Backflow Preventer HX BXFM-16P

Price:元980 /只
Industry Category: Machinery
Product Category:
Brand: 博希阀门
Spec: 50-350mm


Contact Info
  • Add:福建省泉州市晋江市安海镇星塔工业园, Zip: 362200
  • Contact: 王永发
  • Tel:1330699-2838
  • Email:399175352@qq.com

Other Products

Description
Additional Information


Boshi consistently adheres to the business philosophy of "seeking reputation through quality, winning customers with advanced technology," striving to create a modern enterprise with a more pragmatic spirit, superior products, and comprehensive services.

Main products: Free float steam traps, thermodynamic steam traps, inverted bucket steam traps, adjustable bimetal steam traps, lever float steam traps, high-temperature and high-pressure steam traps, and bypass valve steam traps.

Boshi Valve Company's products include American standard, German standard, and national standard: steam traps, globe valves, stainless steel globe valves, ball valves, stainless steel ball valves, plunger valves, plug valves, gate valves, butterfly valves, needle valves, pressure reducing valves, electric valve devices, welding threads, etc.

Main performance indicators of low-resistance backflow preventers:

Specification: DN50-DN300      Nominal pressure: PN1.0-PN1.6       Opening pressure: ≤0.03MPa

Local head loss: ≤0.03MPa Applicable medium: water Applicable temperature: ≤80℃

Stainless Steel Low-Resistance Backflow Prevention ValveHXBXFM-16P Working principle:

The low-resistance backflow preventer consists of a main valve with a two-stage check device and a **-type drainer. The main valve of the dual check device is designed with an equal cross-section flow path and an integrated structure. The valve is equipped with an inlet check device and an outlet check device. The closing sealing force of both check device discs and seats comes from the pressure difference between the outlet and inlet sections. After closing, under normal pressure conditions at both ends, it has a self-sealing function, ensuring that the pressure in the intermediate cavity is zero, forming an air gap between the inlet and outlet sections. The two discs are flexibly connected and interlocked by a connecting rod and an auxiliary spring. The discs are reset by a single main push spring, which does not need to bear the sealing force and pressure difference force of the discs and seats, only overcoming the friction and weight during the closing movement of the discs. Therefore, this main spring can be designed to be softer, ensuring both an air gap when closed and effectively reducing head loss after opening.

Application scenarios of low-resistance backflow preventers:

Low-resistance backflow preventers are mainly used for effective isolation between municipal water supply networks and user networks, or between systems with different water qualities such as domestic water, fire water, air conditioning water, and irrigation water. The main function is to prevent the leakage of poorer quality media from the outlet end to the better quality inlet end when internal leakage occurs after the valve is closed, avoiding backflow contamination. It should be equipped with an internal leakage sensing and drainage引流 device.

Technical features of low-resistance backflow preventers:

1. Small pressure loss and low resistance: At a flow velocity of 2 m/s, the pressure loss of this valve is less than 3 mHg.

2. High reliability. Since the sealing force of the discs and seats of both check devices is achieved through self-sensing of the outlet pressure, the sealing force during check is greatly enhanced, ensuring reliable sealing. Even if both sealing pairs are damaged, the leakage is minimal and quickly discharged by the drainer, ensuring the safety of drinking water.

3. Lightweight, with a structure only 30% of similar products.

4. Easy maintenance, can be installed horizontally or vertically.

Stainless Steel Low-Resistance Backflow Prevention ValveHXBXFM-16P Features:

① Composed of front and rear check valves and an intermediate automatic drainer.

② When leakage occurs in the front and rear check valves, it can automatically drain, block backflow, strictly prevent backflow contamination, and protect the water quality in the upstream pipeline.

③ Ultra-low water loss, significant energy saving: head loss less than 0.04 MPa.

④ Air gap, automatic drainage: When backflow occurs, the main valve closes, the drainer automatically opens, the intermediate cavity pressure is released to zero, achieving an air gap or zero-pressure gap between the upstream and downstream of the main valve, ensuring safe and reliable isolation performance.

⑤ Space and material saving, flexible installation: Small size, light weight, structural length only 30% of existing similar products; can be installed horizontally or vertically.

HX BXFM Low-Resistance Backflow Preventer Main Materials:

No.

Part Name

Material Name

1

Valve Body

HT200

QT450

WCB

CF8

CF8M

2

Ball Valve

Copper

Copper

Copper

304

316

3

Valve Cover

HT200

QT450

WCB

CF8

CF8M

4

Internal Parts

Stainless Steel

Stainless Steel

Stainless Steel

304

316

5

Drainer

Stainless Steel

Stainless Steel

Stainless Steel

CF8

CF8M

HX BXFM Low-Resistance Backflow Preventer Main Dimensions:

Model

Nominal Diameter

External Dimensions

Material

Pressure Rating

Mm

Inch

L

H

H1

Full Stainless Steel

PN10

PN16

HX BXFM

1X

15

1/2

132

75

38

20

3/4

132

75

38

25

1

135

75

38

HX BXFM 

2X

32

11/4

260

128

64

40

11/2

260

128

64

50

2

280

172

82

HX BXFM

 3X

50

2

185

270

160

Body: Ductile Iron or Stainless Steel Internals: Stainless Steel

65

21/2

210

286

166

80

3

225

310

176

100

4

250

335

195

150

6

340

410

235

200

8

400

466

266

HX

BXFM

   5X

65

21/2

320

330

190

Body: Ductile Iron Internals: Stainless Steel

80

3

450

350

210

100

4

500

385

230

150

6

600

510

285

200

8

760

656

336

250

10

950

830

430

300

12

1070

980

510

350

14

1270

1000

600

400

16

1430

1250

680

Installation and Maintenance:

1. For ease of installation and maintenance, and to ensure the normal use of the backflow preventer, a control valve and filter should be installed before the backflow preventer, and an expansion joint (or flexible connector) and control valve should be installed after the backflow preventer.

2. The drain outlet of the backflow preventer's drainer requires an additional引流 pipe, leading to a position ≥100 mm above the sump, with no valves that may block media flow in between; the排污 port size of the sump should ensure smooth drainage.

3. For ease of daily inspection and maintenance, low-resistance backflow preventers should尽量避免 being installed in outdoor pits; it is best to install them indoors with sufficient space, generally with a lower edge ≥300 mm for easy installation and maintenance.

4. Low-resistance backflow preventers can be installed horizontally or vertically. The pipeline media flow direction should match the arrow direction on the main valve body. The test small ball valve on the main valve can face outward for easy inspection.

5. Before installation, the pipeline network must be thoroughly cleaned, and the filter screen in the filter should be regularly cleaned.

Industry Category Machinery
Product Category
Brand: 博希阀门
Spec: 50-350mm
Stock: 100
Manufacturer:
Origin: China / Fujian / Quanzhoushi
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192