HCT-BERT/C E1 Data Error Tester

The HCT-BERT/C is a handheld E1/data error tester featuring a true-color screen, graphical interface, and fully Chinese operation interface. It is used for field maintenance and analysis of E1/G.703 lines, as well as error testing of data lines (V.35, V.24/RS232, RS449, RS530, X.21). The HCT-BERT/C offers comprehensive functions and convenient operation. It can analyze and display test results according to international standards such as G.821, G.826, and M.2100, and also store, statistically analyze, and evaluate test data based on user requirements, making it an essential tool for line quality measurement.

HCT-BERT/C E1 Data Error Tester Features

True-color screen, graphical, fully Chinese operation interface

Multiple types of E1 error analysis, including E1 frame, pattern, CRC, and BPV analysis

Error performance analysis (G.821, G.826, M.2100)

E1 signal frequency offset testing

Configurable time slots for E1 lines (FAS, CAS)

Extraction and insertion of time slots in E1 channels (N×64K data)

Configuration and display of signaling ABCD bits

Configuration and display of Sa bits in time slot 0

Error testing for data ports (interface types: V.35, V.24/RS232, RS449, RS530, X.21)

Offline analysis of BERT performance

Storage of up to 100 configuration and test result files, with user storage and retrieval options

Local or remote control via PC terminal

Intuitive histogram display

Multiple test result output methods: internal storage, LCD screen display, parallel port printing

Built-in high-capacity rechargeable battery for convenient field use.

HCT-BERT/C E1 Data Error Tester Interface Types
E1 interface: RJ45 (balanced), BNC (unbalanced)
Data interface: DB26 (female)
Clock interface: PCM
Print port: DB15 (female)
Control port: USB
HCT-BERT/C E1 Data Error Tester Basic Applications
E1 line error testing
Framed and unframed end-to-end testing
Framed testing
Time slot extraction and insertion
Data line error testing
DTE/DCE n ×64k synchronous testing
Common BERT testing

G.703 E1 Port BERT Testing:

BERT Pattern

63, 127, 511, 2047, 1048575, QRSS, and other patterns, plus user programming

BERT Display Format

ITU G.821, ITU G.826, ITU M.2100

BERT Transmit Error Rate

Forced single error, forced error rate from 0.001 to 0.0000001

Performance Analysis

Logic, Frame, CRC, BPV, E-bit errors, receive count, errored seconds, error-free seconds, bit error rate

E1 Analysis Methods

Channel diagram, Sa bits, signaling ABCD bits, etc.

E1 Port
Specifications

Transmit/Receive Rate

2048K bit/s ± 3ppm @25°C

Line Coding

HDB3

Pulse Characteristics

Complies with ITU-T G.703

Clock Setting

Internal clock, external clock, recovered clock, data port clock

Frame Structure

Unframed, framed; FAS, FAS+CAS; with CRC, without CRC.

Data Port Error Testing:

DTE or DCE Synchronous Error Testing

DTE or DCE Low-Speed Synchronous/Asynchronous Error Testing

Interface

V.35, V.24/RS232, RS449, RS530, X.21

V.24/RS232, V.35, RS449, RS530, X.21

Rate

X 64K (64K…2048K)

Asynchronous: 50 – 115.2K bps;
Synchronous: 150 – 72K bps

BERT Pattern

63, 127, 511, 2047, 32767 ITU standards, etc.

63, 511, 2047, FOX, SPACE, MARK, and ALT