OLT-55 Intelligent Optical Loss Tester Features
· Multi-functional integration: Stable light source + Optical power meter + Loss tester + Return loss test + Length test
· Power test function
· Single fiber bidirectional loss test
· Automatic wavelength identification/switching
· Remote reference value setting
· Pass/Fail judgment setting
· FTTx/PON network applications
· Built-in clock, with editable test cable and fiber sequence number
· USB interface for charging and data upload
· Generates test reports for easy data archiving
· 1000 records storage and management, supports CSV format
· Built-in rechargeable battery allows continuous testing for over 35 hours
· Handheld, compact and portable, easy to operate
· No warm-up required, quick start
· High-resolution color LCD
· Certified by CE, FCC, etc.
The OLT-55 series intelligent optical loss tester integrates a stable light source and optical power meter, featuring an automatic single-fiber bidirectional loss test mode. Combined with Pass/Fail judgment settings, it enhances ease of use and convenience in practical applications while reducing the probability of operational errors.
The OLT-55's rugged and user-friendly design makes it widely applicable in optical network fields such as FTTX, LAN, and CATV. It is a product designed for verifying optical network link loss.
Automatic Single-Fiber Bidirectional Loss/Return Loss Test Option
By connecting one OLT-55 at each end of the same fiber, a single-key operation enables bidirectional link loss/return loss testing on a single fiber. It automatically calculates and displays the average loss of the tested fiber and the total link length, providing customers with optical link loss assessment information.
Automatic Wavelength Identification/Switching
The optical power module of the OLT-55 series optical loss tester can automatically identify wavelength identification signals with digital encryption protocols emitted by its stable light source or any Sinwav SLS-50 series stable light source, and switch to the corresponding wavelength for testing. This function significantly reduces communication needs between test operators and minimizes potential errors.
Suitable for FTTx/PON Testing
The OLT-55 series can be used for certification and routine maintenance of passive optical networks (PON), enabling convenient testing at 1310nm, 1490nm, and 1550nm wavelengths.
Optical Power Test Function
The OLT-55 can test changes in optical power over a period of time and record them in the form of curves.
OLT-55 Series Optical Loss Tester Technical Specifications
Model | OLT-55 | ||||
Stable Light Source | |||||
Wavelength(±20nm) | 1310/1550 | 1310/1490/1550 | 1310/1550/1625 | ||
Spectral Width | ≤5nm | ||||
Output Power | >-4dBm | ||||
Stability | ±0.05dB/15 minutes; ±0.10 dB/8 hours | ||||
Output Mode | CW, 270Hz, 1kHz, 2kHz | ||||
Optical Power Meter | |||||
Calibration Wavelength (1) | 850, 1300, 1310, 1490, 1550, 1625nm | ||||
Test Range (2) | -70~+10dBm | -50~ +27dBm | |||
Unit | W/mW/μW/nW/pW/dBm/dB(REF) | ||||
Detector Type | InGaAs | ||||
Accuracy | ±5%±0.01nW (±0.5 dB@850nm) | ±5%±1nW(±0.5 dB@850nm) | |||
Resolution | 0.01dB | ||||
Automatic Wavelength Identification | Yes (when used with specific stable light sources from our company) | ||||
Modulated Wave Identification | 270, 1K, 2KHz | ||||
Optical Loss Test | |||||
Link Loss Range | 50dB (1550nm, 200km) | ||||
Link Loss Test Accuracy | ±0.25dB | ||||
Link Loss Test Time | < 2 seconds/wavelength | ||||
Optical Return Loss Test (Option) | |||||
Return Loss Test Range | 0~60dB (APC connector) | ||||
Return Loss Test Accuracy | ±0.75dB@(0~50dB), ±1.5dB@(50~60dB) | ||||
Return Loss Test Stability | ±0.5dB@20dB | ||||
General Specifications | |||||
Optical Interface | FC (interchangeable with SC, ST, etc.) | ||||
Data Storage | 1000 sets | ||||
Data Interface | USB | ||||
Backlit Display | Yes | ||||
Auto Power Off | Automatically turns off after 5 minutes of inactivity | ||||
Power Supply | Lithium battery, AC adapter/charger | ||||
Battery Operating Time | Continuous testing time ≥35 hours | ||||
Operating Temperature | -20℃ to 50℃ | ||||
Storage Temperature | -40℃ to 70℃ | ||||
Relative Humidity | 0 to 95% (non-condensing) | ||||
Weight | 350g | ||||
Dimensions (L×W×H) | 177×80×44mm | ||||
Note: (1) Other calibration wavelengths can be customized according to user requirements;
(2) The lower limit of the test range for the 850nm wavelength is: -60 dBm.
The above parameters are subject to change without notice.
OLT-55 Series Optical Loss Tester Standard Configuration:
Main unit, lithium battery, AC adapter/charger, USB data cable, software CD, simple portable soft case, warranty card, CE certificate, calibration certificate, user manual.
| Industry Category | Instruments & Meters |
|---|---|
| Product Category | |
| Brand: | 信维 |
| Spec: | |
| Stock: | |
| Origin: | China / Hebei / Langfangshi |