BCDL-9D High-Precision Microcomputer Fully Automatic Dual-Control Calorimeter
Price:Negotiable
Other Products
Description
Additional Information
BCDL-9D High-Precision Microcomputer Fully Automatic Dual-Control Calorimeter BCDL-9D High-Precision Microcomputer Fully Automatic Dual-Control Calorimeter Hebi Biaochuang Instrument Manufacturing Co., Ltd.
- GB/T 213-2008 "Method for Determination of Calorific Value of Coal"
- GB/T 384-1981 "Method for Determination of Calorific Value of Petroleum Products"
- GB/T 30727-2014 "Method for Determination of Calorific Value of Solid Biofuel"
- GB/T 14402-2007 "Building Materials and Products - Determination of Combustion Performance - Calorific Value"
- JC/T 1005-2006 "Method for Determination of Calorific Value of Cement Raw Meal" "Verification Regulation of Oxygen Bomb Calorimeter"
- ASTM D5865-13 "Test Method for Gross Calorific Value of Coal and Coke"
- ISO 1928:2009 "Solid Mineral Fuels - Determination of Gross Calorific Value"
- CEN/TS 14918 "Solid Biofuels - Determination of Calorific Value"
- High Degree of Automation:
Water circulation system, automatic quantitative inner cylinder water volume and water temperature adjustment; temperature sensing probe and zero-drift bridge temperature measurement circuit, ensuring temperature measurement resolution of 0.0001°C; automatic quantitative inner cylinder water volume, water temperature adjustment, and automatic completion of the entire testing process. - Large-capacity outer cylinder and water tank ensure constant water temperature; under stable environmental conditions, continuous testing of 20 samples can maintain accurate results.
- Strong compression resistance, shortened detection time.
- Cooling correction model ensures accurate test results for high, medium, and low calorific value samples.
- Testing software enables login permission management, full recording of experimental process information, and networked transmission of test data.
- Powerful Functions:
Self-diagnostic prompt function, standard interface, network capability, remote data transmission, connectivity with electronic balance for automatic input of sample weight to avoid manual input errors, conversion of new standard high and low calorific values, calculation of parallel samples and heat capacity, manual recalculation, and other functions.
Accurate Testing:
Heat capacity tracking ensures that water temperature changes do not affect the accuracy of test results; large circulating water volume.
Parameters:
Temperature Range: 5~40°C
Temperature Resolution: 0.0001°C
Precision: RSD ≤ 0.1%
Accuracy: Within the allowable range of standard samples
Power: <500W
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | 鹤壁标创仪器仪表制造有限公司 |
| Spec: | BCDL-9D |
| Stock: | 500 |
| Manufacturer: | |
| Origin: | China / Henan / Hebishi |