China Fully Automatic Bauxite Silicon Magnesium Aluminum Iron Titanium Detection Instrument - China Supplier China Fully Automatic Bauxite Silicon Magnesium Aluminum Iron Titanium Detection Instrument - China Supplier China Fully Automatic Bauxite Silicon Magnesium Aluminum Iron Titanium Detection Instrument - China Supplier China Fully Automatic Bauxite Silicon Magnesium Aluminum Iron Titanium Detection Instrument - China Supplier China Fully Automatic Bauxite Silicon Magnesium Aluminum Iron Titanium Detection Instrument - China Supplier

Fully Automatic Bauxite Silicon Magnesium Aluminum Iron Titanium Detection Instrument

Price:Negotiable
Industry Category: Measurement-Analysis-Instruments
Product Category:
Brand: 标创仪器
Spec: DT-6500


Contact Info
  • Add:鹤壁市山城区朝阳街东段, Zip: 458000
  • Contact: 周经理
  • Tel:13503920302
  • Email:

Other Products

Description
Additional Information

Fully Automatic Bauxite Silicon Magnesium Aluminum Iron Titanium Detection Instrument Fully Automatic Bauxite Silicon Magnesium Aluminum Iron Titanium Detection Instrument Bauxite Testing Instrument Fully Automatic Bauxite Analysis Equipment High-Precision Bauxite Detection Instrument


1 Power Switch: Used to turn the entire machine's power on or off

2 Cuvette: Used to hold the colorimetric solution

3 Drain Button: Drains the solution from the cuvette

4 Display: Shows the instrument's operation interface.

5 Main Unit: Computer main chassis.

Chapter 3 Basic Usage of the Instrument

I. Connection and Power-On of the Instrument

Connect the main unit's power socket to the mains power supply using the power cord, and ensure the instrument is reliably grounded (otherwise, it may be susceptible to interference, causing data fluctuations); check if the drainage hose is securely installed (do not submerge the outlet end of the drainage hose into the waste liquid to avoid poor drainage), and fill the cuvette with distilled water (reference solution). Turn on the computer power, run the element analyzer application, and then turn on the instrument's power switch.

II. Establishment of the Calibration Curve

Establish the calibration curveOn the main interface, select the element symbol to be calibrated, click Calibrate to enter the calibration interface

Step 1: Click Full Scale (100)-----Drain water and pour in the solution------Click A Value Input------Enter the calibration value-----Click C Value % Input.

Step 2: Enter the weight value of the analytical standard sample in mg.

Step 3: Click Establish Curve. If saving other curves, change the curve number.

For multi-point calibration, repeat Step 1. Only after the calibration curve is established within the instrument can sample testing be performed.