MC-3000P Handheld Coating Thickness Gauge
Other Products
I. Overview
The MC-3000P handheld coating thickness gauge uses the electromagnetic induction method to quickly, non-destructively, and precisely measure the thickness of coatings and platings.
This instrument complies with the following standard: GB/T4957-2003 Method for measurement of thickness of non-magnetic coatings on magnetic base metals
II. Main Technical Performance
l Magnetic induction principle, enabling non-destructive measurement of non-magnetic coating thickness (such as zinc, aluminum, chromium, copper, rubber, enamel, paint, etc.) on magnetic metal substrates (such as steel, iron, alloys, and hard magnetic steel, etc.)
l Pen-style integrated thickness gauge, operated with one hand, more portable and easier to use;
l Equipped with temperature compensation function and "phase-locked loop" technology, ensuring stable measurement and adaptability to more worksites;
l Supports system calibration, zero calibration, and one-point calibration methods, with system calibration capable of correcting the entire range;
l Supports large font mode, displaying in large fonts for easy observation and recording of on-site thickness data;
l Supports monitoring mode, allowing setting of upper and lower limit alarms, sound alarms, and colored light alarms to monitor all measurement statuses on-site;
l Supports statistical mode, with real-time on-screen statistics of average, maximum, minimum values, and number of measurements;
l Supports screen inversion display for viewing measurement data in different scenarios.
l Built-in Chinese and English menu display;
l Equipped with storage function, capable of storing up to 1000 measurement values;
l Stored data supports viewing and deletion, allowing deletion of specified data or all data;
III. Technical Parameters:
l Probe type: F1.2 probe
l Measurement principle: Magnetic induction
l Measurement range: 0~1250μm
l Minimum substrate flat diameter: 15mm
l Minimum curvature radius (concave): 6mm
l Minimum curvature radius (convex): 2mm Measurement accuracy (H is thickness value): ±(1~3)%H±1μm or H±2μm
l Display resolution: 0~99.9μm: 0.1μm; 100~9999μm: 1μm;
l Probe type: F for magnetic probe
l Substrate critical thickness: F:1mm
l Storage method: 1000 stored data points
l Calibration methods: System calibration, one-point calibration, zero calibration
l Measurement modes: Simplified mode, monitoring mode, statistical mode
l Display languages: Chinese, English
l Factory reset: Allows user to restore to factory settings
l Operating environment: Relative humidity: ≤90%; Temperature: -10℃~+50℃
l Power supply: LIR2450 rechargeable button battery
l Main unit dimensions: 145mm(L)*37mm(W)*22mm(H)
l Total weight: Approximately 77g (including battery)
III. Standard Configuration of MC-3000P Coating Thickness Gauge:
1. MC-3000P coating thickness gauge main unit one unit
2. LIR2450 rechargeable button battery two pieces
3. Charger + charging cable one set
4. Iron base one piece
5. 5 standard calibration foils one box
6. Lanyard one piece
7. Instrument case one unit
Manual, certificate of conformity, warranty card one set
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | 科电 |
| Spec: | |
| Stock: | 10000 |
| Manufacturer: | |
| Origin: | China / Beijing / Chaoyangqu |