China 2BE1 Series Water Ring Vacuum Pump and Compressor - China Supplier
China 2BE1 Series Water Ring Vacuum Pump and Compressor - China Supplier

2BE1 Series Water Ring Vacuum Pump and Compressor

Price:Negotiable
Industry Category: Machinery
Product Category:
Brand:
Spec:


Contact Info
  • Add:山东省淄博市博山区白塔工业园, Zip: 255200
  • Contact: 吴经理
  • Tel:0533-4686966
  • Email:304026142@qq.com

Other Products

Description
Additional Information

Application and Features:

2BE1 Series Water Ring Vacuum Pumps and Compressors are high-efficiency and energy-saving products developed by our company, incorporating advanced technology from German imports.
This series of pumps features a single-stage, single-acting structure, offering advantages such as simple design, easy maintenance, reliable operation, and high energy efficiency. Compared to the widely used SK, 2SK, and SZ series water ring vacuum pumps in China, the 2BE1 series provides significant benefits including higher vacuum levels, lower power consumption, and more reliable operation, making it an ideal replacement for the SK, 2SK, and SZ series.
The 2BE1 series water ring compressors are low-pressure compressors, with a discharge pressure of approximately 0.1 MPa (gauge pressure) when used as compressors. For detailed parameters, please refer to the catalog.

The main structural features of the 2BE1 series water ring vacuum pumps and compressors produced by our company are as follows:

All bearings are original imported NSK or NTN bearings, ensuring precise positioning of the impeller and high stability during operation.
All impellers are made of ductile iron castings or steel plate welding, ensuring the stability of the 2BE1 vacuum pump impeller under various harsh conditions and significantly extending the service life of the pump.
The pump body is entirely made of steel plate, enhancing the durability of the 2BE1 vacuum pump.
The shaft sleeve, as the most vulnerable part, is made of high-chromium stainless steel, increasing its lifespan by five times compared to ordinary materials.
The pulley (belt drive) uses standard high-precision taper bush pulleys, ensuring reliable operation, long belt life, and easy disassembly.
The coupling (direct drive) uses standard high-strength flexible couplings with polyurethane elastic elements, providing stable and reliable operation and long service life.
The unique top-mounted air-water separator saves space and effectively reduces noise.
All castings are produced using resin sand casting, resulting in excellent surface quality. The castings do not require putty, ensuring optimal heat dissipation for the 2BE1 vacuum pump.
Mechanical seals (optional accessories) are all imported, ensuring no leakage during long-term operation of the 2BE1 series vacuum pumps.

Parts Image Section: Impeller (Ductile Iron), Pump Cover (Cast Iron), Pump Body (Carbon Steel), Disc (Cast Iron), Pump Head Awaiting Inspection (Standard), Impeller (Stainless Steel), Pump Cover (Stainless Steel), Disc (Stainless Steel)

2BE1 Water Ring Vacuum Pump Performance Table

Model Speed
(Drive Type)
r/min
Shaft Power
kW
Motor Power
kW
Matching Motor
380V
Ultimate Vacuum
mbar
Maximum Air Extraction Rate Pump Weight (Complete Unit) kg Installation Dimensions
m³/h m³/min
2BE1 102-0
(Click to View Performance Curve)
1450 (Direct Drive)
1300 (Belt Drive)
1625 (Belt Drive)
1750 (Belt Drive)
5.8
5.0
6.8
8.0
7.5
7.5
7.5
11
Y132M-4
Y132M-4
Y132M-4
Y160M-4
33 mbar
(-0.098 MPa)
235
210
270
290
3.9
3.5
4.5
4.8
295
311
311
346
Pump Head Installation Dimensions

Direct Drive Installation Dimensions

Belt Drive Installation Dimensions
2BE1 103-0
(Click to View Performance Curve)
1450 (Direct Drive)
1300 (Belt Drive)
1625 (Belt Drive)
1750 (Belt Drive)
8.2
7.0
9.9
11.1
11
11
15
15
Y132M-4
Y132M-4
Y132M-4
Y160M-4
33 mbar
(-0.098 MPa)
340
300
385
412
5.7
5.0
6.4
6.9
363
347
388
388
2BE1 151-0
(Click to View Performance Curve)
1450 (Direct Drive)
1100 (Belt Drive)
1300 (Belt Drive)
1625 (Belt Drive)
1750 (Belt Drive)
10.8
7.2
9.2
13.2
14.8
15
11
11
15
18.5
Y160L-4
Y160M-4
Y160M-4
Y160L-4
Y180M-4
33 mbar
(-0.098 MPa)
405
300
360
445
470
6.8
5.0
6.0
7.4
7.8
469
428
444
469
503
2BE1 152-0

(Click to View Performance Curve)
1450 (Direct Drive)
1100 (Belt Drive)
1300 (Belt Drive)
1625 (Belt Drive)
1750 (Belt Drive)
12.5
8.3
10.5
15.0
17.2
15
11
15
18.5
22
Y160L-4
Y160M-4
Y160L-4
Y180M-4
Y180L-4
33 mbar
(-0.098 MPa)
465
340
415
510
535
7.8
5.7
6.9
8.5
8.9
481
437
481
515
533
2BE1 153-0
(Click to View Performance Curve)
1450 (Direct Drive)
1100 (Belt Drive)
1300 (Belt Drive)
1625 (Belt Drive)
1750 (Belt Drive)
16.3
10.6
13.6
19.6
22.3
18.5
15
18.5
22
30
Y180M-4
Y160L-4
Y180M-4
Y180L-4
Y200L-4
33 mbar
(-0.098 MPa)
600
445
540
660
700
10.0
7.4
9.0
11.0
11.7
533
480
533
551
601
2BE1 202-0
(Click to View Performance Curve)
970 (Direct Drive)
790 (Belt Drive)
880 (Belt Drive)
1100 (Belt Drive)
1170 (Belt Drive)
1300 (Belt Drive)
17
14
16
22
25
30
22
18.5
18.5
30
30
37
Y200L2-6
Y180M-4
Y180M-4
Y200L-4
Y200L-4
Y225S-4
33 mbar
(-0.098 MPa)
760
590
670
850
890
950
12.7
9.8
11.2
14.2
14.8
15.8
875
850
850
940
945
995
Pump Head Installation Dimensions

Direct Drive Installation Dimensions

Belt Drive Installation Dimensions
2BE1 203-0
(Click to View Performance Curve)
970 (Direct Drive)
790 (Belt Drive)
880 (Belt Drive)
1100 (Belt Drive)
1170 (Belt Drive)
1300 (Belt Drive)
27
20
23
33
37
45
37
30
30
45
45
55
Y250M-6
Y200L-4
Y200L-4
Y225M-4
Y225M-4
Y250M-4
33 mbar
(-0.098 MPa)
1120
880
1000
1270
1320
1400
18.7
14.7
16.7
21.2
22.0
23.3
1065
995
995
1080
1085
1170
2BE1 252-0
(Click to View Performance Curve)
740 (Direct Drive)
558 (Belt Drive)
660 (Belt Drive)
832 (Belt Drive)
885 (Belt Drive)
938 (Belt Drive)
38
26
31.8
49
54
60
45
30
37
55
75
75
Y280M-8
Y200L-4
Y225S-4
Y250M-4
Y280S-4
Y280S-4
33 mbar
(-0.098 MPa)
1700
1200
1500
1850
2000
2100
28.3
20.0
25.0
30.8
33.3
35.0
1693
1460
1515
1645
1805
1805
2BE1 253-0
(Click to View Performance Curve)
740 (Direct Drive)
560 (Belt Drive)
660 (Belt Drive)
740 (Belt Drive)
792 (Belt Drive)
833 (Belt Drive)
885 (Belt Drive)
938 (Belt Drive)
54
37
45
54
60
68
77
86
75
45
55
75
75
90
90
110
Y315M-8
Y225M-4
Y250M-4
Y280S-4
Y280S-4
Y280M-4
Y280M-4
Y315S-4
33 mbar
(-0.098 MPa)
2450
1750
2140
2450
2560
2700
2870
3020
40.8
29.2
35.7
40.8
42.7
45.0
47.8
50.3
2215
1695
1785
1945
1945
2055
2060
2295
2BE1 303-0
(Click to View Performance Curve)
740 (Direct Drive)
590 (Direct Drive)
466 (Belt Drive)
521 (Belt Drive)
583 (Belt Drive)
657 (Belt Drive)
743 (Belt Drive)
98
65
48
54
64
78
99
110
75
55
75
75
90
132
Y315L2-8
Y315L2-10
Y250M-4
Y280S-4
Y280S-4
Y280M-4
Y315M-4
33 mbar
(-0.098 MPa)
4000
3200
2500
2800
3100
3580
4000
66.7
53.3
41.7
46.7
51.7
59.7
66.7
3200
3200
2645
2805
2810
2925
3290
Pump Head Installation Dimensions

Direct Drive Installation Dimensions

Belt Drive Installation Dimensions
2BE1 305-1
2BE1 306-1
(Click to View Performance Curve)
740 (Direct Drive)
590 (Direct Drive)
490 (Belt Drive)
521 (Belt Drive)
583 (Belt Drive)
657 (Belt Drive)
743 (Belt Drive)
102
70
55
59
68
84
103
132
90
75
75
90
110
132
Y355M1-8
Y355M1-10
Y280S-4
Y280S-4
Y280M-4
Y315S-4
Y315M-4
160 mbar
(-0.085 MPa)
4650
3750
3150
3320
3700
4130
4650
77.5
62.5
52.5
55.3
61.2
68.8
77.5
3800
3800
2950
3000
3100
3300
3450
2BE1 353-0
(Click to View Performance Curve)
590 (Direct Drive)
390 (Belt Drive)
415 (Belt Drive)
464 (Belt Drive)
520 (Belt Drive)
585 (Belt Drive)
620 (Belt Drive)
660 (Belt Drive)
121
65
70
81
97
121
133
152
160
75
90
110
132
160
160
185
Y355L2-10
Y280S-4
Y280M-4
Y315S-4
Y315M-4
Y315L1-4
Y315L1-4
Y315L2-4
33 mbar
(-0.098 MPa)
5300
3580
3700
4100
4620
5200
5500
5850
88.3
59.7
61.7
68.3
77.0
86.7
91.7
97.5
4750
3560
3665
3905
4040
4100
4100
4240
2BE1 355-1
2BE1 356-1
(Click to View Performance Curve)
590 (Direct Drive)
390 (Belt Drive)
435 (Belt Drive)
464 (Belt Drive)
520 (Belt Drive)
555 (Belt Drive)
585 (Belt Drive)
620 (Belt Drive)
130
75
86
90
102
115
130
145
160
90
110
110
132
132
160
185
Y355L2-10
Y280M-4
Y315S-4
Y315S-4
Y315M-4
Y315M-4
Y315L1-4
Y315L2-4
160 mbar
(-0.085 MPa)
6200
4180
4600
4850
5450
5800
6100
6350
103.3
69.7
76.7
80.8
90.8
98.3
101.7
105.8
5000
3920
4150
4160
4290
4300
4350
4450

Note: The motor power selected above can operate under most conditions. If the discharge pressure is high (0.02–0.05 MPa), the motor power should be increased accordingly. If the shaft power of the 2BE1 vacuum pump is low during normal operation, a motor power close to the shaft power can be selected for greater energy efficiency.

Note: The water temperature significantly affects the performance of water ring vacuum pumps. The performance curves of water ring vacuum pumps are measured at a water temperature of 15°C. Therefore, when selecting a water ring vacuum pump, the air extraction rate should be corrected. For correction methods, please refer to: The Impact of Water Temperature on Water Ring Vacuum Pump Performance

2BE1 Series Water Ring Vacuum Pump Water Consumption

Model
Standard Speed rpm
Speed Range rpm
Water Consumption m³/h at the Following Suction Pressures (mbar, absolute)
≤160
200
300
400
500
600
700
>800
2BE1 102-0
1450
1300–1750
1.1
1.极速赛车开奖直播历史记录

Industry Category Machinery
Product Category
Brand:
Spec:
Stock:
Origin:
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192