I. Fengyushun TF-01SA Medium Frequency Physiotherapy ApparatusTherapeutic Principle
1. Analgesic effect: (1) Medium frequency current can excite the thick fibers of peripheral nerves, and through "gate" control, inhibit the thin fibers that transmit pain sensations, achieving an analgesic effect. (2) Medium frequency current can dilate blood vessels, promote blood circulation, and accelerate the removal of local pain-inducing substances. (3) Medium frequency electrical stimulation can also cause the human body to release morphine-like substances with analgesic effects.
2. Improve local blood circulation and promote the dissipation of inflammation:
(1) Axon reflex and triple response: The axon reflex refers to when current acts on the surface of the human body, the electrical stimulation travels through the afferent nerves to the posterior horn of the spinal cord, exciting the efferent nerves, causing the small arteries of the skin to dilate, resulting in diffuse redness on the skin surface under the electrode. When the skin is stimulated, it also releases substances such as histamine, substance P, and acetylcholine, which can dilate arteries. Additionally, electrical stimulation itself can directly cause arterial dilation. The above three aspects are referred to as the triple response.
(2) Muscle contraction effect: Low-frequency modulated waves or interference waves can cause muscle contraction. The rhythmic contraction and relaxation of muscles create a "pump" effect, thereby promoting the return of blood and lymphatic fluid.
(3) Metabolic products of muscle activity: Metabolic products of muscle activity, such as lactic acid, ATP, ADP, etc., have significant vasodilatory effects.
3. Soften scars and release adhesions: Medium frequency current can widen the gaps between cells and tissues, releasing adhered connective tissue fibers, muscle fibers, and nerve fibers.
4. Excite neuromuscular tissue: Low-frequency modulated waves or interference waves can change the ion permeability of the cell membrane, leading to a change in the polarity inside and outside the membrane, depolarizing the membrane potential, and forming action potentials, thereby exciting nerves and muscles and producing muscle contraction.
I. Technical Parameters of the TF-01SA Medium Frequency Therapy Apparatus;
1. Power supply: AC: 220V±22V; 50Hz±1Hz; Input power: 65VA;
2. Ambient temperature: +10℃~+40℃ Ambient humidity: 30%~75% Atmospheric pressure: 700hpa~1060hpa;
*3. Medium frequency: 1kHz~10kHz Error: ±30%;
*4. Pulse width: 50us~500us; Error: ±30%;
*5. Modulation wave frequency: 0~440Hz; Error: ±30%;
*6. Modulation amplitude: 0~100%; Error: ±5%
*7. Difference frequency range: Within 0~100Hz.
*8. Dynamic rhythm: 4s~10s.
*9. Difference frequency change cycle: 15s~30s.
Output modes: ① Computer medium frequency (medium and low frequency bidirectional current); Thermal output (0~3 adjustable thermal output levels)
10. Modulation waveforms: Base wave: Pulse square wave; Modulation wave: Exponential wave, forward triangular wave, backward triangular wave, constant amplitude wave, sine wave, triangular wave, step wave, constant amplitude wave
11. Maximum output current: The effective value of the maximum output current is not greater than 100mA.
12. Open circuit prompt and recovery: During operation (output dose greater than 10), if the output is open-circuited, the yellow indicator light will illuminate. If the open circuit fault is resolved, the yellow indicator light will turn off.
13. The temperature of the electrode plate under heating conditions does not exceed 60℃.
14. Continuous operation time: Not less than 4 hours.
15. The effective load impedance of this product is 500 ohms, and the above technical parameters should be measured under this load.
16. When measured with a load resistor within the range specified in this manual with an error not exceeding ±10%, the deviation of the measured value from the pulse width, pulse repetition frequency, and amplitude value specified in the random documents or marked on the equipment must not exceed ±30%.
17. This product mainly consists of a main unit, output electrodes, and wires.
18. This product has 4 output channels, 4 LCD display areas, and no protective cover.
19. Environmental conditions for transportation and storage: Ambient temperature: -20℃~55℃ Ambient humidity: ≤95% Atmospheric pressure: 700hpa~1060hpa;