Measurement Principle:
Ultrasonic sludge interface measurement involves an ultrasonic sensor installed underwater, which emits a pulse of ultrasonic waves toward the sludge surface. This pulse signal reflects off the sludge-water interface and is received back by the sensor. The time taken from the emission of the ultrasonic wave to its reception is proportional to the distance between the sensor and the measured object's surface. The instrument detects this time and, based on the current temperature (measured by the sensor) and the speed of sound underwater, calculates the distance from the measured object's surface to the sensor (i.e., the spatial distance), which is then converted into a liquid level value. The distance W from the liquid level surface to the sensor is proportional to the travel time T of the sound wave: W = V × T / 2 (where V is the speed of sound in water). The user sets the height H from the probe to the bottom of the tank, and the instrument automatically converts the pulse travel time T into the corresponding spatial distance value W. The measured value L is then calculated as the difference between H and W.
Features:
lFully intelligent, multifunctional, high measurement performance, and strong environmental adaptability;
lVarious output options including one 4-20mA output, relay high/low/fault alarm control output, RS485 communication output, and more;
lHigh-integration converter with multiple output functions;
lThree relay outputs;
lAdvanced circuit design and software algorithms to eliminate on-site interference, ensuring stable and reliable measurement results.
Typical Applications:
lWater and wastewater treatment, power, mining, and other industries.
Technical Parameters:
Measurement Range | 0.2-12m |
Measurement Unit | m |
Resolution | 0.001(m) |
Basic Error | ±1%F.S |
Temperature | -10-150.0°C |
Temperature Resolution | 0.1°C |
Temperature Error | ±0.3°C |
Current Output | 2 channels 4~20mA |
Communication Output | RS485 Modbus RTU |
Other Functions | Data logging/Data upload |
Relay Control Contacts | Three groups: 5A 240VAC, 5A 28VDC or 120VAC |
Optional Power Supply | 85-265VAC, 9-36VDC, Power: ≤3W |
Operating Environment | No strong magnetic field interference except for the Earth's magnetic field. |
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | 西安东升 |
| Spec: | DS-USL100 |
| Stock: | |
| Origin: | China / Shaanxi / Xianshi |