DS-TU600 Online Turbidity Analyzer
Contact Info
- Add:西安市高新区锦业二路逸翠尚府北区8号楼1单元1701, Zip: 710000
- Contact: 魏经理
- Tel:15686405979
- Email:1528126689@qq.com
Other Products
Measurement Principle
The turbidity sensor is based on infrared scattering light technology, meaning that infrared light emitted by the light source scatters when passing through the sample being measured, and the intensity of the scattered light is proportional to the turbidity. The turbidity sensor is equipped with a scattered light receiver at a 90° angle to analyze the intensity of this scattered light and determine the turbidity value.
Features
lInfrared scattering light technology eliminates the influence of sample color;
lOptional cleaning brush for automatic cleaning, significantly reducing sensor maintenance;
lDigital sensor with strong anti-interference capability and long transmission distance;
lStandard digital signal output enables integration and networking with other devices without a controller
lEasy and quick on-site installation of the sensor, enabling plug-and-play.
lSimple to use, reliable results, and interface operation indicators to reduce operational errors;
lEquipped with a visual alarm system providing critical warning functions;
lController supports wall mounting/panel mounting/clamp mounting;
lReverse connection protection for sensor power supply polarity;
lProtection against incorrect power connection for sensor RS485 A/B terminals.
Typical Applications
lOnline turbidity monitoring at water plant inlets, sedimentation tanks, and other stages;
lOnline turbidity monitoring in sewage plants, various industrial process water, and wastewater treatment processes.
SensorTechnical Parameters
Measurement Range | Turbidity: 0.01-3000 NTU |
Measurement Accuracy | Less than ±5% of measured value or ±0.5NTU, whichever is greater |
Repeatability | ±3% |
Resolution | 0.01NTU, 0.1NTU, depending on range |
Pressure Range | ≤0.1Mpa |
Calibration | Sample calibration, slope calibration |
Sensor Main Materials | Body: SUS316L; Upper and lower covers: PPS+fiberglass; Cable: PUR |
Sensor Power Supply Voltage | 9~36VDC |
Output | MODBUS RS-485 output |
Storage Temperature | -15 to 50℃ |
Operating Temperature | 0 to 45℃ (non-freezing) |
Self-Cleaning | Optional automatic cleaning device |
Protection Rating | P68/NEMA6P |
Cable Length | Standard 10-meter cable, extendable to 100 meters |
Dimensions | Diameter 49mm*Length 230.5mm |
Weight | 0.8KG |
DS-115TControllerTechnicalParameters:
Display Output | 128*64 graphic dot matrix LCD with strong LED backlight for operation under direct sunlight |
Power Supply | AC power supply: 85-500VAC (50/60HZ); DC power supply: 9~36VDC |
Main Materials | PA66+GF25+FR (upper cover); Powder-coated aluminum alloy (lower shell) |
Output | Three channels of 4-20mA |
Relay | Three relays with programmable response parameters and values |
Digital Communication | Equipped with MODBUS RS485 communication function for real-time transmission of measured values |
Storage Temperature | -20 to 70℃ |
Operating Temperature | -15 to 60℃ |
Waterproof Rating | IP65/NEMA4X |
Dimensions | 145mm*125mm*162mm (L*W*H) |
Weight | 1.35KG |
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | 西安东升 |
| Spec: | DS-TU600 |
| Stock: | |
| Origin: | China / Shaanxi / Xianshi |