Business Scope of Jiangsu Duan Environmental Protection: Research, development, production, sales, installation, service, and maintenance of pumps, complete water treatment equipment, environmental protection equipment, mechanical parts, electrical control equipment, valves, high and low voltage switch cabinets; technical consulting services for water treatment equipment; water supply and drainage engineering design; environmental protection engineering construction; chemical product sales; import and export business of various commodity technologies. (Projects subject to approval by law may only commence business activities after approval by relevant departments.)
Working Principle of Duan Environmental Protection QXB Submersible Centrifugal Aerator:
Aeration by centrifugal aerators is a technique to intensely mix air and water, aiming to dissolve oxygen in water or to remove gases and volatile substances into the air. In other words, it is a method to promote the exchange of substances between gas and liquid.
It has important functions of mixing and oxygenation. The conversion of oxygen from air to water through aeration and the mass transfer operation from gas phase to liquid phase, along with the dispersion mass transfer principle, are more commonly explained by the Lewis and Whitman two-film theory.
The two-film theory posits that there are gas and liquid films at the gas-water interface. The air and liquid films, as well as the liquid film itself, are in turbulent flow conditions; between the gas and liquid films, it is laminar flow without convection, and under certain conditions, pressure and concentration gradients can occur. If the oxygen concentration in the liquid film is lower than that in the water, oxygen from the air will continue to disperse through the liquid film into the water body. Clearly, a direct way to overcome the liquid film barrier is to alter the "gas-liquid" interface.
Aeration mixing works this way, with specific methods including: reducing bubble size, increasing the number of bubbles, enhancing liquid turbulence levels, increasing the depth of aeration equipment, and extending the contact time between bubbles and liquid. Aeration equipment is a commonly used treatment method in sewage treatment.
Applications of QXB Submersible Centrifugal Aerator:
Uses of Centrifugal Aerator The QXB centrifugal submersible aerator is used in aeration tanks and aeration grit chambers of sewage treatment plants for oxygenating and mixing sewage mixtures, as well as for biochemical treatment of sewage or oxygenation in aquaculture ponds.
How to Select a Submersible Centrifugal Aerator:
It is recommended to consider factors such as liquid delivery volume, head, liquid properties, pipeline layout, and operating conditions.
1. Flow rate is one of the important performance data for selecting a centrifugal aerator, directly related to the production and delivery capacity of the entire system. If the design process can calculate the normal, minimum, and maximum flow rates for the centrifugal aerator. When selecting a centrifugal aerator, base the selection on the flow rate, taking into account the normal flow rate. If there is no maximum flow rate, usually 1.1 times the normal flow rate can be taken as the maximum flow rate.
2. Head is another important performance data for selecting a centrifugal aerator. Generally, select based on the head with an additional 5%—10% margin.
3. Liquid properties, including the name of the liquid medium, physical properties, chemical properties, and other characteristics. Physical properties include temperature °C, density d, viscosity u, diameter of solid particles in the medium, and gas content, etc., which relate to the system head, calculation of effective NPSH, and selection of the appropriate pump type. Chemical properties mainly refer to the chemical corrosiveness and toxicity of the liquid medium, which are important bases for selecting pump materials and the type of shaft seal.
4. Pipeline layout conditions refer to data such as liquid delivery height, delivery distance, delivery direction, the lowest liquid level on the suction side, discharge side liquid level, as well as pipeline specifications and length, materials, pipe fitting specifications, quantity, etc., to calculate system head and check NPSH.
5. Operating conditions include many aspects, such as the operating T of the liquid, saturated vapor pressure P, suction side pressure PS, discharge side container pressure PZ, altitude, ambient temperature, whether operation is intermittent or continuous, and whether the pump position is fixed or movable.
Before leaving the factory, Duan Environmental Protection QXB centrifugal submersible aerators undergo several underwater tests to ensure reliable use of the product. To ensure the service life of the submersible centrifugal aerator, regular inspection and maintenance are recommended.
Cleaning
1. To prevent the accumulation of impurities inside the submersible aerator at different times, clean water can be pumped through the aerator for cleaning. If the submersible aerator is not used for a long time, it should be stored in a dry place and protected from freezing.
2. Oil filling and changing: The oil chamber of the submersible aerator is filled with an appropriate amount of lubricating oil before leaving the factory. This oil should be replaced annually. Oil change should be carried out as follows: position the submersible aerator so that the oil plug faces downward, loosen the plug, drain the lubricating oil, then clean the oil chamber with cleaning oil, refill with an appropriate amount of lubricating oil, replace with a new O-ring, and tighten the plug. If water is found in the oil, flush the oil chamber as specified, refill with oil, and tighten the plug with the O-ring. Recheck after three weeks; if the oil becomes emulsified again, inspect the mechanical seals. Replace if necessary (please contact our company's maintenance department). Note: The oil is transformer oil.
3. Operational faults In case of operational faults, if the cause cannot be determined and the troubleshooting methods provided later do not resolve the issue, do not use temporary fixes or attempt unauthorized repairs or disassembly.
Fault Phenomenon | Cause | Remedy |
Power equipment overload | 1 Inlet pool does not meet requirements 2 Impeller of submersible aerator entangled with debris 3 Friction between impeller and guide vane of submersible aerator 4 Speed of submersible aerator exceeds specified value | 1 Improve inlet conditions 2 Remove debris, clean with water 3 Check impeller wear, readjust installation 4 Adjust prime mover to meet rated speed |
Reduced or no aeration | 1 Submersion depth of aerator is too deep 2 Outer edge of impeller blades worn or partially damaged 3 Incorrect rotation direction of submersible aerator 4 Loose impeller 5 Submersible aerator clogged with debris | 1 Raise the submersible aerator 2 Replace impeller 3 Correct rotation direction 4 Tighten screws 5 Remove debris, clean with water |
Noise or vibration during operation | 1 Base of submersible aerator not sturdy enough or nuts loose 2 Friction between impeller and guide vane 3 Loose impeller screws or partially damaged blades 4 Unstable inlet conditions 5 Submersible aerator clogged with debris | 1 Reinforce base, tighten screws 2 Check gap between impeller and guide vane 3 Tighten screws or replace impeller 4 Adjust inlet conditions 5 Remove debris, clean with water |
Submersible aerator fails to start or fuse blows | 1 Open circuit in winding, connection, or cable 2 Submersible aerator clogged 3 Leakage of electricity or water 4 Short circuit | 1 Check with ohmmeter 2 Cut power, remove debris 3 Check insulation; if below specified value, dry out 4 Use after inspection and repair |
Circuit breaker or overload protector trips after starting submersible aerator | 1 Low voltage 2 High voltage 3 Incorrect motor wiring or confused connections 4 Electrical fault in control cabinet | 1 Temporarily disuse or, if due to long line voltage drop, thicken power line 2 Install transformer to adjust voltage to specified value 3 Adjust wiring and connections 4 Check and replace electrical components |
After-sales Instructions of Duan Environmental Equipment (Jiangsu) Co., Ltd.:
1. Logistics and Freight Instructions
Submersible sewage pumps, submersible mixers, etc., are heavy goods. For Jiangsu, Zhejiang, and Shanghai, products under 50KG can be shipped by express; over 50KG, logistics must be used. Comprehensive protectors, leakage protectors, and thermal protectors are delivered door-to-door by express.
We cooperate with dozens of reputable logistics companies and will select one with fast speed and favorable prices for you.
Freight can be prepaid or collected on delivery, which will be specified before quotation.
2. Online Ordering
Our company vigorously develops online business. You are welcome to place orders online, which provides dual protection: both contract constraints and payment confirmation guarantees.
3. Maintenance and Upkeep.
All our products come with a one-year warranty. For quality issues within 3 months, the seller bears the round-trip repair freight; within one year, both parties share half of the freight each. Please note. If inspection shows it is not a quality issue, the buyer needs to pay for repair costs and round-trip freight. For replaced parts, we promise to charge only the cost price. We provide lifelong maintenance.
4. Taxes
We are general taxpayers and can issue 13% VAT invoices as required by the contract. They will be express mailed to customers before the 25th of each month, please rest assured.
Jiangsu Duan Environmental Protection offers various models of submersible aerators:
QXB0.75KW QXB1.5KW QXB2.2KW QXB3.0KW QXB4.0KW QXB5.5KW
QXB7.5KW QXB10KW QXB11KW QXB15KW QXB18.5KW QXB22KW
Or customized according to customer requirements.
WQ Submersible Sewage Pump | AS Cutter Pump | AV Scraper Suction Pump | QJB Submersible Mixer | WL Vertical Sewage Pump | WQB Explosion-proof Sewage Pump | LS Vertical In-line Pump | Coupling Device | LB-05 Leakage Protector | NS-4 Comprehensive Protector | INT Thermal Protector | FK2 Float Switch | ZQB Submersible Axial Flow Pump | SQB Hyperboloid Mixer | QJB-W Sludge Return Pump | QJB Submersible Propeller | QXB Submersible Aerator | QSB Submersible Jet Aerator | Bar Screen | Scraper Suction Machine | Prefabricated Pump Station | Frame Mixer | Paddle Mixer | Shaftless Spiral Conveyor | Grit Washer | Belt Conveyor |
| Industry Category | Environment Industry |
|---|---|
| Product Category | |
| Brand: | 杜安环保 |
| Spec: | QXB-3 |
| Stock: | 999 |
| Manufacturer: | |
| Origin: | China / Jiangsu / Nanjingshi |