I. Introduction to the Needle Flame Test Apparatus
The Needle Flame Test Apparatus is a commonly used testing device for evaluating the combustion performance of materials. It simulates real fire conditions by exposing materials to a flame of standard size and shape at specific temperatures, measuring their degree of combustion under various conditions. This test is widely applied in fields such as construction, automotive, and electronic products to ensure compliance with safety requirements.
The Needle Flame Test Apparatus is part of the IEC60695-2-2 (2004), GB5169.5-2008, GB4706.1, IEC60695-11-5:2016, and IEC60695-2-2 standards for the No. 1 needle flame test apparatus.
It is suitable for research, production, and quality inspection departments of electrical and electronic equipment and their components, including lighting, low-voltage electrical appliances, household appliances, machine tool electrical appliances, motors, power tools, electronic instruments, electrical meters, information technology equipment, office electrical equipment, electrical connectors, and accessories. It is also applicable to industries such as insulating materials, engineering plastics, or other solid combustible materials.
The Needle Flame Test Apparatus is constructed with a cold-rolled steel plate and high-grade spray-painted exterior. It uses a needle-shaped burner of specified dimensions (Φ0.9mm) fueled by a specific gas (butane or propane) to apply a timed, directional flame at a 45° angle to the sample. The ignition risk of small flames caused by fault conditions inside the equipment is assessed based on whether the sample and the ignition underlay are ignited, as well as the duration of combustion and the length of the burn.
II. Instrument System Configuration
1. Thermometer | 14. Flame Adjustment - Ignition Only, No Timing |
2. Gas Flow Adjustment | 15. Start - Begin Test When Ready |
3. Ignition Device | 16. Stop - Halt Operation |
4. Thermocouple - Measure Flame Calorific Value | 17. Pause - Pause Combustion Duration Timer |
5. Temperature Measurement Copper Head | 18. Reset - Clear Timer and Burner Carriage/Reset |
6. Burner Carriage Transmission Mechanism | 19. Temperature Measurement - Calibrate Flame Temperature |
7. Ignition Device | 20. Exhaust Fan - Ventilation Equipment |
8. Burner | 21. Lighting - Illumination Equipment |
9. Sample Fixture | 22. Debug - Burner Carriage (Move Right, Adjust Sample to Proper Position) |
10. Burner Carriage | 23. Up/Down - Sample Platform (Raise or Lower) |
11. Sample Platform | 24. Flame Application Timer |
12. Exhaust Fan | 25. Combustion Duration Timer |
13. Power Switch |
III. Product Technical Parameters
Needle Burner | Stainless steel, inner hole Φ0.5mm ± 0.1mm, outer diameter ≤Φ0.9mm, length ≥ 35mm |
Burner Angle | Vertical (for adjusting and measuring flame height) and tilted 45° (during testing) |
Ignition Underlay | 10mm thick white pine board, covered with 12g/m²~30g/m² standard silk paper, placed 200mm ± 5mm below the flame application point |
Combustion Gas | 95% butane gas (reference gas), propane gas may also be used |
Gas Flame Temperature Gradient | 100℃ ± 2℃ to 700℃ ± 3℃ (room temperature to 999℃), 23.5s±1.0s (1s to 999.9s) |
Flame Height | 12mm ± 1mm (adjustable) |
Flame Application Time | 5s, 10s, 20s, 30s, 60s, 120s -1 +0 s (1s to 999.9s, digitally displayable and preset) |
Combustion Duration | 1s to 999.9s (digitally displayed, can be manually paused to maintain display) |
Test Space | ≥ 0.3m³, black background |
Temperature Sensor | K-type Φ0.5mm insulated armored thermocouple, armor sheath heat-resistant up to 1100℃ |
Dimensions | Width 1120mm × Depth 520mm × Height 1250mm, exhaust hole Φ100mm |
Test Power Supply | 220V 0.5kVA |
IV. Test Operation Steps
1. Preset Flame Application Time and Combustion Duration:
A. Preset Flame Application Time
B. Preset Combustion Duration
2. Sample Testing:
A.Press the start button; the device will open the solenoid valve and automatically ignite. The carriage moves right to the target position, and the flame application timer starts automatically;
B.When the preset flame application time countdown completes, the burner cuts off the gas and extinguishes, and the carriage returns to the left initial position. The system automatically starts the combustion duration timer. Press the pause button when the sample's residual flame extinguishes to stop the combustion duration timer;
C.Press the reset button to clear test data and return to the initial state;
D.Repeat the above steps if retesting is needed.
V. Operation Precautions
1.Combustion duration automatically starts timing after the flame application time ends and only stops when the pause button is pressed;
2.Keep the combustion chamber clean, especially the needle tip, to avoid clogging. Clean the combustion chamber after each test while the power is off;
3.The fan and lighting are controlled by independent buttons for turning on and off;
4.The temperature measurement thermocouple is a fragile component; handle with care. It is not covered under product warranty;
5.After testing, remove the test gas cylinder and press the flame adjustment button to verify that residual gas in the pipeline is fully combusted and released.
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | 今森 |
| Spec: | KS-52B |
| Stock: | 10000 |
| Manufacturer: | |
| Origin: | China / Shanghai / Fengxianqu |