Product Model | Main Technical Specifications | Unit Price (¥) | Remarks |
Spectral Bandwidth nm | Wavelength Range nm | Wavelength Minimum Interval nm | Wavelength Accuracy | Baseline Flatness | Stability (λ500nm) | Stray Light | Measurement Range | Photometric Accuracy |
UV-7502PCS UV-Visible Spectrophotometer | 0.5 1 2 4 | 200-1000 | Wavelength Auto 0.1 | ±0.5 Bandwidth 2 | ±0.004A Bandwidth 2 | ±0.002A/h (Bandwidth 2) | ≤0.1%T at (λ220, 340, Bandwidth 2) | 0-125%T -0.097-3.000A 0-1 999C 1999F | ±0.5%T Bandwidth 2 | 38000 Includes Software | Variable Slit |
UV-7502PCS (756CRT) UV-Visible Spectrophotometer | 2 | 200-1000 | Wavelength Auto 0.1 | ±0.5 | / | ±0.002A/h | ≤0.15%T at (λ220, 340, | 0-125%T -0.097-2.70A 0-1999C 1999F | ±0.5%T | 32000 Includes Software | |
UV-7502CS UV-Visible Spectrophotometer | 0.5 1 2 4 | 200-1000 | Wavelength Auto 0.1 | ±1 | / | ±0.002A/h (Bandwidth 2) | ≤0.2%T at (λ220, 340, | 0-125%T -0.097-2.70A 0-1999C 1999F | ±0.5%T | 22000 | Variable Slit |
UV-7502C (751) UV-Visible Spectrophotometer | 2 | 200-1000 | Wavelength Auto 0.1 | ±1 | ±0.004A | ±0.002A/h | ≤0.2%T at (λ220, 340, | 0-125%T -0.097-2.70A 0-1999C 1999F | ±0.5%T | 19000 | |
UV-7504PC (756MC) UV-Visible Spectrophotometer | 4 | 200-1000 | Wavelength Auto 0.1 | ±1 | / | ±0.004A/h | ≤0.3%T at (λ220, 340, | 0-125%T -0.097-2.50A 0-1999C 1999F | ±0.5%T | 25000 Includes Software | |
UV-7504C (754) UV-Visible Spectrophotometer | 4 | 200-1000 | Wavelength Auto 0.1 | ±1 | / | ±0.004A/h | ≤0.3%T at (λ220, 340, | 0-125%T -0.097-2.50A 0-1999C 1999F | ±0.5%T | 15000 | |
UV-7504 (752W) UV-Visible Spectrophotometer | 4 | 200-1000 | Wavelength Auto 0.1 | ±2 | ±0.004A (Bandwidth 2) | ±0.004A/h | ≤0.5%T at (λ220, 340, | 0-125%T -0.097-2.50A 0-1999C 1999F | ±0.5%T | 9980 | |
723PCS Visible Spectrophotometer | 1 | 2 | Wavelength Auto 0.1 | Wavelength Auto 0.1 | ±0.5 (Bandwidth 2) | ±0.004A | ±0.004A/h (Bandwidth 2)(at 500nm) | ≤0.15%T at (λ340, 420, Bandwidth 2) | 0-125%T -0.097-3.00A 0-1999C 1999F | ±0.5%T | 11800 Includes Software | Variable Slit |
□ 4 | ○ 5 |
723PC Visible Spectrophotometer | 4 | 325-1000 | Wavelength Auto 0.1 | ±1 | / | ±0.004A/h (λ500nm) | ≤0.2%T at (λ340, 400) | 0-125%T -0.097-2.70A 0-1999C 1999F | ±0.5%T | 7850 Includes Software | |
723C (230G) Visible Spectrophotometer | 4 | 325-1000 | Wavelength Auto 0.1 | ±1 | / | ±0.004A/h (λ500nm) | ≤0.3%T at (λ240, 420) | 0-125%T -0.097-2.50A 0-1999C 1999F | ±0.5%T | 6250 | |
722-100 Visible Spectrophotometer | 5 | 325-1000 | Wavelength Manual 1 | ±2 | / | Dark Current 0.2%T/3min | ≤0.5%T at (λ340, 420) | 0-125%T -0.097-1.99A 0-1999C 1999F | ±%T | 3900 | Sample Cell 100 |
Light Current 1.0%T/3min |
722 Visible Spectrophotometer | 5 | 325-1000 | Wavelength Manual 1 | ±2 | / | Dark Current 0.2%T/3min | ≤0.5%T at (λ340, 420) | 0-125%T -0.097-1.99A 0-1999C 1999F | ±1%T | 3600 | |
Light Current 1.0%T/3min |
721-100 Visible Spectrophotometer | 6 | 360-1000 | Wavelength Manual 1 | ±3 | / | Dark Current 0.2%T/3min | ≤1%T at (λ360, 420) | 0-125%T -0.097-2.70A 0-1999C 1999F | ±1.5%T | 3100 | Sample Cell 100 |