THLXD-ZM-0.38-20A Highway Street Lamp Lighting Load Voltage Stabilization Control Device During the customization process of AC street lamp conversion lighting voltage stabilizers, the implementation of phase sequence error protection customization can enhance the system functionality of the AC power voltage regulation and stabilization device itself, improving phase sequence protection. This way, if the AC street lamp conversion lighting voltage stabilizer experiences voltage disconnection errors or output issues during operation, the phase sequence error protection function will issue an alarm, promptly notifying maintenance personnel to perform repairs and maintenance on the AC street lamp conversion lighting voltage stabilizer.

Compared to pure compensation types, the advantages of the voltage stabilization control device are: Since the thyristor network of the voltage stabilization control device is located on the output side of the compensation transformer and is further stepped down by an autotransformer, it not only reduces the switching voltage of the thyristor (from 220V to 200V or lower) but also suppresses the surge current generated during switching (the autotransformer itself acts as a high-power reactor). This significantly enhances the operational reliability and anti-interference capability of the thyristor.

 

THLXD-ZM-0.38-20A Highway Street Lamp Lighting Load Voltage Stabilization Control Device Product Specifications
Unit Name (Amperes): 20A, 30A, 40A, 45A, 50A, 60A, 63A, 80A, 100A, 120A, 125A, 150A, 160A, 170A, 180A, 190A, 200A, 250A, 300A, 315A, 400A;
Unit Name (Kilowatts): LE-20KVA, LE-30KVA, LE-40KVA, LE-50KVA, LE-35KVA, LE-45KVA, LE-65KVA, LE-60KVA, LE-80KVA, LE-100KVA, LE-120KVA, LE-150KVA, LE-160KVA, LE-180KVA, LE-200KVA, LE-250KVA, LE-225KVA, LE-300KVA

Main Forms of Controller Winding Short-Circuit Faults

Under the electromagnetic force of a controller short-circuit, winding damage and lead displacement are potential consequences. Both experimental research and operational practice indicate that the damage to controller windings under short-circuit electromagnetic forces mainly manifests in the following forms:

(1) Winding deformation causing turn insulation rupture, leading to inter-turn short circuits. This is the primary form of damage for small distribution controllers with smaller diameters under radial tensile electromagnetic forces during short circuits.

(2) Winding deformation reducing main insulation strength, resulting in main insulation breakdown. This is the main form of damage for medium-sized and larger power controller windings under radial tensile short-circuit forces. Therefore, when designing controller winding short-circuit strength, the cumulative effect of residual deformation under short-circuit electromagnetic forces must be considered.

(3) Radial instability of windings. For windings placed inside the core or intermediate windings of multi-winding controllers, under short-circuit conditions, they may experience circumferential compression caused by radial short-circuit electromagnetic forces. Radial instability of inner windings in medium-sized and larger controllers is the primary form of damage under radial short-circuit electromagnetic forces.

(4) Axial instability of windings. Axial instability is the main form of winding damage under the combined action of axial and radial short-circuit electromagnetic forces.

(5) Overall displacement and tilting of three-phase controller windings. This occurs under three-phase symmetrical short-circuit fault conditions.

THLXD-ZM-0.38-20A Highway Street Lamp Lighting Load Voltage Stabilization Control Device Product Features

1. Extends the service life of light sources effectively. Does not generate any harmonic pollution to the grid, expanding capacitor margin. Effectively filters current fluctuations and impacts, reducing reactive power loss, ensuring stable operation of the grid and lighting equipment. Lowers the operating temperature of lamps, saving cooling energy, and can extend lamp service life by 30%.

2. Low-risk, high-return investment, significantly reducing costs. Excellent performance-to-price ratio, with a service life of up to 100,000 hours. Users can recover the investment cost of energy-saving equipment within approximately 6-12 months. After recovering the cost, it generates long-term profits with significant economic benefits.

3. Easy installation. Can be directly installed on power supply lines without modifying existing circuits. Installation is simple and convenient. Intelligent control, dynamic tracking, automatic energy saving, no need for debugging or dedicated personnel. Implements strict工艺流程 and quality testing, ensuring safety, reliability, and ease of operation. Attractive appearance, compact size, does not affect the unified layout of the installation site.

 

THLXD-ZM-0.38-20A Highway Street Lamp Lighting Load Voltage Stabilization Control Device Main Technical Specifications

1. Input voltage: AC380V+25%, AC220V+25%

2. Output voltage: Automatically limits voltage and stabilizes for energy saving according to set values;

3. Three-phase regulation: Allows unbalanced loads;

4. Voltage stabilization accuracy: ±1%

5. Current limit protection setting: 1.6Ie

6. Overload protection threshold during startup: 1.4Ie, with inverse time characteristics

7. Overload protection threshold during operation: 1.1Ie, with inverse time characteristics

8. Lamp switching clock error: 1 minute/month

9. Output voltage setting: Set separately for each phase, continuously adjustable above 195V phase voltage, enabling different voltage outputs. Factory default setting is 220V.

10. Data retention during power failure: Over five years

11. Operating temperature range: -20 / +40℃

THLXD-ZM-0.38-20A Highway Street Lamp Lighting Load Voltage Stabilization Control Device is a startup device that combines power electronics technology, microprocessors, and fuzzy control theory, specifically designed for various specifications of three-phase asynchronous motors. It enables smooth, step-less startup and stopping of motors, avoiding mechanical and electrical impacts caused by direct startup, star-delta startup, or autotransformer reduced-voltage startup. It effectively reduces starting current and power distribution capacity, avoiding the need for capacity expansion investments.

Selection of Intelligent Lighting Energy-Saving Distribution Cabinets 3.1 Energy-saving cabinet capacity selection Assuming the energy-saving cabinet supplies power to 90 high-pressure sodium lamps (400W/lamp). According to the technical manual of standard high-pressure sodium lamps, the rated current of a 400W high-pressure sodium lamp is 4.6A. Total current per phase = 4.6A/lamp × 90 lamps ÷ 3 phases × 1.1 = 151.8A. The rated current of the energy-saving distribution cabinet should be greater than or equal to this current. Referring to the JCT distribution cabinet manual, a JCT-3100 intelligent lighting energy-saving distribution cabinet with three-phase 100kVA capacity and a rated current of 152A per phase can be selected.