CoEpo-APF Series Active Power Filter (Wall-mounted)
Contact Info
- Add:高新区纬二十六路中交科技城西区9号楼, Zip: 710000
- Contact: 陈先生
- Tel:18192712620
- Email:chenxin@coepower.com
Other Products
The CoEpo-APF series active power filter is connected in parallel to the power system. Through external sampling circuits, it collects real-time power system data. The device's internal core computing chip analyzes harmonic component data in the system and controls high-frequency IGBT switching to output a current equal in magnitude but opposite in direction to the system's harmonic current, thereby canceling out harmonic currents in the system to achieve harmonic current management.
Product Features
1. Capable of harmonic management, reactive power compensation, and three-phase unbalance management, with flexible adjustment of function priorities based on site requirements.
2. Full response time of 10ms, enabling the system to maintain THDI below 5%, PF at 0.99, and three-phase unbalance below or equal to 3%.
3. Can filter 2nd to 50th order harmonics, with the ability to select any harmonic order within this range and adjust the filtering output to achieve the desired filtering effect.
4. Reactive power compensation range (-1 to 1), with capacitive and inductive reactive power switching on demand, meeting the reactive power compensation needs of equipment with rapid instantaneous reactive power changes, such as stamping and welding machines.
5. Modular design for easy maintenance and installation, supporting both rack-mounted and wall-mounted installation methods.
6. Independent air duct design ensures excellent heat dissipation capability, along with a comprehensive temperature detection system for real-time monitoring of device temperature.
7. Comprehensive protection functions with 16 types of protection to ensure device and system safety.
| APF Active Filter Specifications | ||||||
| Voltage Level | 0.4KV/0.48KV/0.69KV | |||||
| Current Level | 50A | 75A | 100A | 150A | 200A | Stackable Capacity |
| System Parameters | ||||||
| Rated Input Voltage | 304Vac-456Vac/288Vac-576Vac/414Vac-759Vac | |||||
| Grid Frequency | 50Hz (Range: 45Hz-55Hz), 60Hz (Range: 55Hz-65Hz) | |||||
| Reactive Power Compensation | Capable of reactive power compensation, compensation range (1 to -1) | |||||
| Three-Phase Unbalance Regulation | Capable of three-phase unbalance regulation | |||||
| Protection Functions | Grid overload, under-voltage, phase loss, three-phase instantaneous overcurrent, three-phase delayed overcurrent, bus overvoltage, bus undervoltage, overheating, fan failure, power supply failure, current limiting protection, frequency protection, fuse failure | |||||
| Grid Structure | Three-Phase Four-Wire | Three-Phase Three-Wire | ||||
| Performance Indicators | ||||||
| Filtering Range | 2nd to 50th order | |||||
| Switching Frequency | 20KHz | |||||
| Filtering Capability | THDi <5% (rated load, THDu <1%) | |||||
| Fast Response Time | <40μs | |||||
| Full Response Time | <10ms | |||||
| Target PF | -1 to +1 | |||||
| Communication and Monitoring | ||||||
| Communication Interface | RS485, Ethernet Port | |||||
| Communication Protocol | Modbus Protocol, Transmission Control Protocol/Internet Protocol | |||||
| Module Display Interface | 4.3-inch Touchscreen 7-inch LCD Touchscreen | 7-inch LCD Touchscreen | ||||
| Installation Method | Wall-mounted/Rack-mounted | Cabinet-mounted | ||||
| Line Entry Method | Top Entry/Rear Entry | |||||
| Centralized Monitoring | Optional 10-inch centralized monitoring touchscreen, each capable of managing up to 6 APF modules | |||||
| Width*Depth*Height (mm) | 540x545x190/540x551x219 | 600x800x2000 | ||||
| CT Wiring Method | Supports Source Side/Load Side | |||||
| Environmental Requirements | ||||||
| Operating Temperature | -10℃ to +45℃ | |||||
| Relative Humidity | 5% to 95%, non-condensing | |||||
| Protection Level | IP20 | |||||
| Cooling Method | Intelligent Air Cooling | |||||
| Altitude | 2000m, derating required for higher altitudes | |||||
| APF Selection Reference Table (Reference Values) | |||||
| Commercial Real Estate/Subway | Medical/Metallurgy | Data Centers | Multimedia | Petrochemical/Heavy Industry | |
| Transformer (KVA) | 15% | 20% | 25% | 30% | 35% |
| Recommended Configuration Capacity (A) | |||||
| 200 | 50 | 50 | 50 | 75 | 100 |
| 250 | 50 | 50 | 75 | 75 | 100 |
| 315 | 50 | 75 | 100 | 100 | 125 |
| 400 | 50 | 75 | 100 | 125 | 150 |
| 500 | 75 | 100 | 125 | 150 | 200 |
| 630 | 100 | 125 | 175 | 200 | 250 |
| 800 | 100 | 150 | 200 | 250 | 300 |
| 1000 | 150 | 200 | 250 | 300 | 350 |
| 1250 | 175 | 250 | 300 | 400 | 450 |
| 1600 | 200 | 300 | 400 | 500 | 550 |
| 2000 | 250 | 375 | 500 | 600 | 700 |
| 2500 | 300 | 450 | 600 | 700 | 850 |
| All data above are empirical values of harmonic distortion under normal operating conditions of the transformer. | |||||