The CoEpo-UBC series pole-mounted power quality comprehensive management device is a product specifically developed and designed to address power quality issues in power distribution station areas of the power system. Based on the CoEpo-SVG series static var generator module, it performs three-phase unbalance regulation, bidirectional reactive power compensation, and harmonic management in distribution station areas to protect the cleanliness and stability of the power grid.
Advantages and Features
1. Comprehensive functionality, primarily focusing on three-phase unbalance compensation, while also providing reactive power compensation and harmonic filtering capabilities.
2. Flexible configuration, allowing adjustment of functional emphasis based on the actual power quality conditions of the system. The device automatically adjusts its output according to system conditions.
3. Safe and reliable, featuring mature module technology, excellent heat dissipation design, and protective design to ensure safe and stable operation. It is connected in parallel to the system to ensure system stability and safety.
4. Flexible installation, supporting various installation methods such as bracket mounting, clamp mounting, and floor mounting, making it suitable for diverse scenarios.
Working Principle
Product Selection
CoEpo-UBC Series Power Quality Comprehensive Management Device | |||||
Basic Parameters | |||||
Device Capacity | 30kVar | 50kVar | 75kVar | 100kVar | |
Rated Voltage | 285Vac ~ 475Vac | ||||
Operating Frequency | 50Hz | ||||
Device Phase System | Three-phase four-wire system | ||||
Device Functions | |||||
Unbalance Regulation Capability | Three-phase unbalance degree < 3% | ||||
Fast Response Time | ≤40us | ||||
Full Response Time | ≤10ms | ||||
Filtering Function | Capable of filtering 3rd/5th/7th/9th/11th/13th harmonics | ||||
Reactive Power Compensation Function | (1 ~ -1) capacitive and inductive bidirectional compensation | ||||
Protection Functions | Grid overvoltage, undervoltage, phase loss, three-phase instantaneous overcurrent, three-phase delayed overcurrent, bus overvoltage, bus undervoltage, overheating, fan failure, power supply failure, current limiting protection, frequency protection, fuse failure | ||||
Communication Function | Local Wifi, GPRS optional | ||||
Basic Characteristics | |||||
Installation Method | Bracket (F-type/H-type), clamp mounting (only for 30kVar/50kVar) | ||||
Inlet Method | Side inlet | ||||
Cooling Method | Intelligent air cooling | ||||
Noise | < 60dB, background noise less than 40dB | ||||
Protection Level | IP 44 | ||||
Ambient Temperature | -30℃ to +45℃ | ||||
Relative Humidity | ≤95%, no condensation | ||||
Altitude | 2000m, derating for higher altitudes | ||||
Dimensions (mm) | 880*620*310 | 880*620*310 | 880*620*310 | 880*620*350 | |