Low Voltage SVG Static Var Generator (Wall-mounted)
Contact Info
- Add:高新区纬二十六路中交科技城西区9号楼, Zip: 710000
- Contact: 陈先生
- Tel:18192712620
- Email:chenxin@coepower.com
Other Products
Product Description
The fundamental principle of the Static Var Generator (SVG) is to connect a three-phase bridge inverter circuit directly to the grid via a reactor. By appropriately adjusting the phase and amplitude of the AC output voltage on the bridge circuit or directly controlling its AC-side current, the circuit can generate the required reactive current to achieve reactive power compensation for the system. Supported voltage levels: 690V/480V/440V/400V/220V/110V.
Real-time tracking of system reactive power changes, linear compensation, ensuring the system power factor is always maintained at 0.99. Bidirectional reactive compensation range (capacitive and inductive), real-time adjustment based on system reactive power changes to prevent over-compensation or under-compensation issues. Active compensation output avoids common problems in traditional reactive compensation equipment such as resonance, harmonic amplification, and low efficiency in low-voltage compensation.
Modular design allows for easy expansion, maintenance, and wiring. Flexible configuration and convenient installation, supporting wall-mounted and rack-mounted installations to adapt to various on-site requirements.
Advantages and Features
1. Wide compensation range: (+1) to (-1)
2. Fast response time: full compensation response ≤10ms
3. Low-order harmonic compensation capability: compensates for 3rd to 13th order harmonics
4. Three-phase unbalance compensation capability: adjusts system three-phase unbalance
5. Flexible configuration:可以根据系统实际电能质量现状,设置治理优先级,将模块利用率最大化
6. Parallel connection to the system with 16 protection functions for comprehensive equipment and system safety
7. User-friendly operating system, easy to understand, with a built-in electronic operation manual for随时查询
Performance Parameters
| SVG Static Var Generator Specifications | ||||||
| Voltage Level | 0.4KV/0.48KV/0.69KV | |||||
| Current Level | 30Kvar | 50Kvar | 75Kvar | 100Kvar | Stackable Capacity | |
| System Parameters | ||||||
| Rated Input Voltage | 304Vac-456Vac/288Vac-576Vac/414Vac-759Vac | |||||
| Grid Frequency | 50Hz (range: 45Hz-55Hz), 60Hz (range: 55Hz-65Hz) | |||||
| Reactive Compensation | (1 ~ -1) Bidirectional capacitive and inductive compensation | |||||
| Filtering Function | Capable of filtering 3rd/5th/7th/9th/11th/13th order harmonics | |||||
| Three-Phase Unbalance Adjustment | Capable of adjusting three-phase unbalance | |||||
| Protection Functions | Grid overload, under-voltage, phase loss, three-phase instantaneous overcurrent, three-phase delayed overcurrent, Bus overvoltage, bus undervoltage, overheating, fan failure, power supply failure, current limiting protection, frequency protection, fuse failure | |||||
| Grid Structure | Three-phase four-wire | Three-phase three-wire | ||||
| Performance Indicators | ||||||
| Filtering Range | 2nd to 50th order | |||||
| Filtering Capability | THDi <5% (rated load, THDu <1%) | |||||
| Fast Response Time | <50μs | |||||
| Full Response Time | <10ms | |||||
| Target PF | -1 to +1 | |||||
| Communication and Monitoring | ||||||
| Communication Interface | RS485, Ethernet port | |||||
| Communication Protocol | Modbus protocol, Transmission Control Protocol/Internet Protocol | |||||
| Module Display Interface | 4.3-inch touch screen 7-inch LCD touch screen | 7-inch LCD touch screen | ||||
| Installation Method | Wall-mounted/Rack-mounted | Cabinet-type | ||||
| Width*Depth*Height (mm) | 540x545x190/540x551x219 | 600x800x2000 | ||||
| CT Wiring Method | Supports source-side/load-side | |||||
| Environmental Requirements | ||||||
| Operating Temperature | -30℃ to +45℃ | |||||
| Relative Humidity | 5% to 95%, non-condensing | |||||
| Protection Level | IP20 | |||||
Applicable Scenarios: Suitable for working conditions with significant fluctuations in reactive power and a certain degree of harmonic distortion.
Performance Features: The CoEpo-SVG series Static Var Generator provides bidirectional reactive power compensation from 1 to -1, ensuring the system power factor remains at 0.99. It also features 3rd/5th/7th/9th/11th/13th order harmonic filtering and three-phase unbalance adjustment capabilities.
| Industry Category | Electrical-Equipment-Supplies |
|---|---|
| Product Category | |
| Brand: | |
| Spec: | |
| Stock: | |
| Origin: | China / Shaanxi / Xianshi |