Product Name: Fixed Hydrogen Chloride Gas Detection Alarm
Model: JQB-G-HCL
Product Description:
JQB-G-HCL Fixed Hydrogen Chloride Gas Detection Alarm is a newly developed gas detector by Kunlun Coast, featuring original imported sensors and a new 32-bit low-power processor; dashboard display interface with simultaneous numerical and progress bar display, elegant and user-friendly; 4-layer circuit board design for enhanced weak signal processing and anti-interference capability; imported 16-bit AD chip and unique signal processing algorithm ensure higher accuracy and stability in measurement data; multiple output signals including 4~20mA, RS485, and 200~1000Hz for easy integration with various alarm controllers, PLCs, DCS, and other control systems; explosion-proof structural design suitable for various hazardous industrial environments; widely used in metallurgy, petroleum and petrochemical, municipal, chemical, and other industries.
Fixed Hydrogen Chloride Gas Detection Alarm Product Features:
◆ Original imported high-performance sensor with high measurement accuracy, good repeatability, and long service life;
◆ 16-bit AD chip and 4-layer circuit board design for stronger weak signal processing and anti-interference capability;
◆ Dashboard display interface design, industry-leading, elegant and user-friendly reading, reflecting humanized detail design;
◆ White, orange, and red three-color backlight design for clear normal and alarm status indication;
◆ Multiple units selectable: mg/m3, ppm, VOL, LEL;
◆ Embedded 32-bit ultra-low-power processor with unique signal processing algorithm for fast response and high stability;
◆ Automatic protection function against high-concentration gas impact, with factory reset to prevent misoperation;
◆ Equipped with infrared remote control for easy operation without opening the cover;
◆ Optional three-wire 4~20mA, RS485, 200~1000Hz signal output, relay output, data recovery, data storage, and other functions;
◆ Two cable entry ports for convenient on-site installation;
◆ Gas chamber structure for easy sensor replacement without on-site calibration;
◆ Excellent mechanical design, gas chamber made of military-grade high-strength aluminum profile, wear-resistant and corrosion-resistant, suitable for complex and harsh industrial environments; scientific gas chamber design ensures real-time monitoring accuracy;
◆ Explosion-proof rating: Exd II CT6, certified by the Explosion-proof Electrical Inspection Center.
Technical Specifications:
Name | Description |
Detection Gas: | Hydrogen Chloride |
Detection Principle: | Electrochemical Principle |
Detection Method: | Fixed online long-term continuous detection, diffusion detection method; |
Fixed online continuous detection, with external air pump for pump-suction circulation detection method (air pump optional); | |
Measurement Range: | 0-10ppm, 100ppm, 500ppm, 1000ppm, 2000ppm, 5000ppm (optional, custom ranges available) |
Resolution: | 0.01ppm (0-100ppm), 0.1ppm (100-1000ppm), 1ppm (above 1000ppm) |
Accuracy: | ≤±3% (actual concentration, subject to sensor performance) |
Operation Method: | Infrared remote control for remote and close-range operation, easy setup |
Repeatability: | ≤±1% |
Zero Drift: | ≤±1% (F.S/year) |
Response Time: | ≤20 seconds (T90) |
Recovery Time: | ≤20 seconds |
Explosion-Proof Mark: | Exd II CT6 Gb |
Protection Rating: | IP66 |
Output Signal: | User-selectable based on actual field requirements, transmission distance up to 2000 meters (single-core 1mm² cable) |
Three-wire 4-20mA current signal output, compatible with alarm controllers, PLCs, DCS, and other control systems (standard configuration) | |
Digital signal RS-485 output, ModBus RTU communication protocol (optional) | |
Frequency signal 200~1000Hz output (optional) | |
Two relay outputs: passive contact capacity 220VAC 0. or 5VDC 0. | |
Remote data transmission and status alarm via wireless module (optional); Ethernet access available | |
Main Material: | Housing: ADC12 aluminum alloy, sturdy, wear-resistant, and corrosion-resistant (optional 316 stainless steel housing) |
Gas chamber: High-strength wear-resistant and corrosion-resistant aluminum profile, durable (optional 316 stainless steel gas chamber) | |
Installation Method: | Wall-mounted pipeline integrated (pipeline external thread specification: M45X1.5mm, optional pipeline adapter screw connector, weldable) |
Operating Temperature: | -30℃ to +60℃ (customizable for special requirements) |
Operating Humidity: | ≤95%RH, no condensation (filter available for humidity >90%RH and condensation) |
Relative Humidity: | 10% to 95%RH |
Power Supply: | 24VDC (normal operating voltage range 12~30VDC) |
Power Consumption: | 1.5W |
Operating Pressure: | ≤200Kpa |
Dimensions: | 180mm*140mm*92mm (H*W*D) |
Weight: | Approx. 1.6Kg |
Compliance Standards: | GB15322.1-2003, GB3836.1-2010, GB3836.2-2010, GB3836.4-2010 |
Quality Assurance: | One-year warranty, free repair during warranty period. |
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | 昆仑海岸 |
| Spec: | JQB-G-HCL |
| Stock: | |
| Origin: | China / Beijing / Haidianqu |