Water Cycle Cooling and Heating Temperature Control System
Contact Info
- Add:深圳市龙岗区坪地街道年丰社区横岭中路1号第七栋, Zip: 518116
- Contact: 李大红先生
- Tel:0755-29084657
- Email:szkawai@yeah.net
Other Products
Water Circulation Refrigeration and Heating Temperature Control System
Introduction
Unit Refrigeration Principle
The compressor operates, converting low-temperature, low-pressure gaseous refrigerant into high-temperature, high-pressure gaseous refrigerant, which enters the condenser. Part of the heat from the refrigerant inside the condenser is expelled by external cooling water or cooling fans. After releasing heat, the refrigerant liquefies into a high-temperature, high-pressure liquid and flows out. It then passes through a dryer filter for drying and filtration, enters the expansion valve for throttling (a rapid cooling process) and pressure reduction, and liquefies into a low-temperature, low-pressure liquid before entering the evaporator for heat exchange. The low-temperature, low-pressure liquid refrigerant absorbs heat from the surrounding medium (water, oil) outside the evaporator. During the heat absorption process, the refrigerant temperature remains unchanged while its volume changes. After absorbing heat, the low-pressure hydraulic refrigerant vaporizes into a low-temperature, low-pressure gaseous refrigerant and enters the compressor. It is compressed into a high-temperature, high-pressure gaseous state and enters the condenser, thereby completing the entire refrigeration cycle.
Unit Heating Principle
Based on the refrigeration principle, the compressor operates, converting low-temperature, low-pressure gaseous refrigerant into high-temperature, high-pressure gaseous refrigerant, which passes through a four-way valve and a liquid storage tank before entering the condenser. The heat inside the condenser is utilized to heat the water tank, with heated water reaching up to 90 degrees Celsius. After releasing heat, the refrigerant liquefies into a high-temperature, high-pressure liquid and flows out. It then passes through a dryer filter for drying and filtration, enters the expansion valve for throttling (a rapid cooling process) and pressure reduction, and liquefies into a low-temperature, low-pressure liquid before entering the evaporator for heat exchange. The low-temperature, low-pressure liquid refrigerant absorbs heat from the surrounding medium (water, oil) outside the evaporator. During the heat absorption process, the refrigerant temperature remains unchanged while its volume changes. After absorbing heat, the low-pressure hydraulic refrigerant vaporizes into a low-temperature, low-pressure gaseous refrigerant and enters the compressor. It is compressed into a high-temperature, high-pressure gaseous state and enters the condenser, thereby completing the entire heating cycle.
Features
Control System
1. Control components, microcomputer boards, single modules, PLCs, etc., use market-recognized brands such as LG, Bangpu, Siemens, Schneider, and Mitsubishi.
2. To enhance the stability and safety of the Water Circulation Refrigeration and Heating Temperature Control System during use, the EU quality management system certification has been actively implemented in the production process. Quality control is rigorously managed in supplier selection, and load specifications are strictly standardized. The unit's performance includes additional protection devices such as phase loss and reverse phase protection, motor overload protection, high and low pressure protection, water shortage automatic alarm, low temperature and anti-freezing protection.
After-Sales Service
1.
2.
3.
4.
5.
Unit Technical ParametersAir energy water refrigeration heating machine set Technical Parameters
Model | Refrigeration Capacity | Heating Capacity | Compressor | Evaporator | Condenser | Water Pump | Dimensions Shape dimension | |||||
kcal/h | kw | kw | kw | hp | L | inch | m3/h | m3/h | kw | mpa | cm | |
JRW-01QA | 2494 | 2.9 | 3.1 | 0.75 | 1 | 18 | 3∕4" | 1.2 | 1000 | 0.37 | 0.18 | 75×62×90 |
JRW-02QA | 4988 | 5.8 | 6.2 | 1.5 | 2 | 40 | 3∕4" | 1.2 | 2000 | 0.37 | 0.18 | 88×65×105 |
JRW-03QA | 7482 | 8.7 | 9.3 | 2.2 | 3 | 45 | 3∕4" | 1.8 | 3000 | 0.37 | 0.18 | 104×67×110 |
JRW-04QA | 9976 | 11.6 | 12.4 | 3 | 4 | 60 | 3∕4" | 2.6 | 4000 | 0.37 | 0.18 | 120×60×115 |
JRW-05QA | 12470 | 14.5 | 15.5 | 3.75 | 5 | 70 | 1 | 3 | 5000 | 0.75 | 0.18 | 130×75×120 |
JRW-06QA | 14964 | 17.4 | 18.6 | 4.5 | 6 | 90 | 1 | 3.6 | 6000 | 0.75 | 0.18 | 135×80×135 |
JRW-08QA | 19552 | 23.2 | 24.8 | 6 | 8 | 140 | 2" | 5 | 8000 | 0.75 | 0.18 | 145×90×140 |
JRW-10QA | 24940 | 29 | 31 | 7.5 | 10 | 160 | 2" | 6 | 10000 | 1.5 | <极>155×95×150 | |
JRW-12QA | 29928 | 34.8 | 37.2 | 9 | 12 | 170 | 2"极> | 7.5 | 12000 | 1.5 | 0.18 | 160×100×160 |
JRW-15QA | 37410 | 43.5 | 46.5 | 11 | 15 | 200 | 2" | 9 | 15000 | 1.5 | 0.18 | 170×110×175 |
JRW-20QA | <极> 49880 | 58 | 62 | 15 | 20 | 300 | 2" | 12 | 20000 | 2.2 | 0.18 | 185×120×180 |
JRW-25QA | 59856 | 69.6 | 77.5 | 18 | 25 | 300 | 2.5" | 15 | 25000 | 2.2 | 0.18 | 190×125×185 |
JRW-30QA | 74820 | 87 | 93 | 22.5 | 30 | 450 | 2.5" | 18 | 30000 | 3 | 0.18 | 210×140×200 |
JRW-40QA | 99760 | <极>124 | 30 | 40 | 600 | 2.5" | 25 | 40000 | 3.75 | 0.18 | 220×150×210 | |
JRW-50QA | 124700 | 145 | 155 | 37.5 | 50 | 700 | 3" | 32 | 50000 | 3.75 | 0.18 | 240×160×220 |
JRW-60QA | 149640 | 174 | 186 | 45 | 60 | 800 | 3" | 40 | 60000 | 3.75 | 极.18 | 270×170×240 |
JRW-40QAS | 103200 | 120 | 126 | 30 | 40 | - | 2.5 | 26 | 40000 | - | 200×65×160 | |
JRW-50QAS | 129000 | 150 | 157.5 | 37.5 | 50 | - | 3" | 30 | 50000 | - | - | 200×65×165 |
JRW-60QAS | 154800 | 180 | 189 | 45 | 60 | - | 4" | 36 | 60000 | - | - | 250×65×165 |
JRW-70QAS | 180600 | 210 | 220.5 | 52.5 | 70 | - | 4" | 42 | 70000 | - | - | 255×65×165 |
JRW-80QAS | 206400 | 240 | 252 | 60 | 80 | - | 4" | 48 | 80000 | - | - | 280×65×180 |
JRW-100QAS | 258000 | 300 | 315 | 75 极> | 100 | - | 4" | 62 | 100000 | - | - | 320×65×180 |
JRW-120QAS | 309600 | 360 | 378 | 90 | 120 | - | 4" | 74 | 120000 | - | - | 350×80×180 |
JRW-140QAS | 361200 | 420 | 441 | 105 | 140 | - | 4.5" | 86 | 140000 | - | - | 360×80×190 |
JRW-150QAS | 399900 | 456 | 472.5 | 112 | 150 | - | 4.5" | 92 | 150000 | - | - | 360×80×180 |
JRW-160QAS | 426560 | 496 | 504 | 120 | 160 | - | 4.5" | 106 | 160000 | - | - | 390×110×160 |
JRW-180QAS | 479880 | 558 | 567 | 135 | 180 | - | 4.5" | 112 | 180000 | - | - | 410×110×160 |
JRW-200QAS | 533200 | 620 | 630 | 150 | 200 | - | 4.5" | 118 | 200000 | - | - | 410×140×160 |
Note: 1. Refrigeration compressor: Maximum operating temperature 45°C, uses refrigerant R22. Refrigeration compressor: Support highest temperature 45 ℃、Refrigerant R22 for use.
2. Screw unit energy automatic control at 75%-50%-25%. Screw water chillers energy automatic control for 75%-50%-25%.
3. Evaporation temperature inlet water 12°C, evaporation temperature outlet water 7°C. Condensation temperature inlet water 30°C, condensation temperature outlet water 35°C. Evaporation temperature into the water 12 ℃、Evaporation temperature water 7 ℃、Cooling water temperature into 30 、Cooling water temperature for 35.
4. The above parameters are subject to change without prior notice. The above parameters are subject to change without prior notice.