I. Functional Features:
Customized Service: Develop test solutions based on customer requirements to flexibly adapt to different scenarios.
Convenient Editing: Directly edit test parameters, items, and other information within the software interface.
Power-On Self-Test: Automatic startup inspection ensures testing only after passing checks, reducing failure risks.
Data Monitoring: Real-time display of test data with highlighted non-conforming items.
Permission Management: Hierarchical permission settings to ensure data security and equipment stability.
Data Interface: MES/IOT interface supports automatic upload of test data and resumable transmission in case of network interruption.
Scan-to-Start: Scanning automatically matches the corresponding vehicle model's test group without manual changes.
Device Interconnection: Built-in web server enables device information interconnection within the LAN for real-time data queries.
Protocol Adaptation: Supports custom battery communication protocols to enhance device compatibility.
Log Recording: The upper computer software AIP-PEC includes communication log recording for easy fault tracing and analysis.
II. Product Overview:
This system adopts a modular hardware and software architecture, allowing flexible expansion of hardware modules and customization of test programs. It can meet various testing needs such as battery pack safety performance testing, internal resistance testing, and BMS functional testing. It features automatic testing, automatic judgment, automatic data storage, automatic upload to MES systems, and remote data query capabilities, providing an efficient, reliable, and convenient solution for end-of-line testing of battery packs in the energy storage industry.
III. Equipment Specifications:
Item | Specification |
Power Supply | AC220V/10A |
Ambient Temperature | -5~40℃ |
Ambient Humidity | Not exceeding 75% R.H (no condensation) |
Equipment Dimensions | 800*800*1750 (W*D*H, excluding air conditioner) |
Equipment Weight | 200kg |
IV. Equipment Test Items:
No. | Item Name | Test Content |
1 | Insulation Resistance Test | Test insulation values between positive/negative high-voltage terminals and the housing. |
2 | Withstand Voltage Test | Test leakage current values between positive/negative high-voltage terminals and the housing. |
3 | Equipotential Test | Test resistance values between grounding points and bolt points. |
4 | Insulation Detection Function Verification | Simulate multiple resistance specifications to detect BMS insulation status. |
5 | High-Voltage Sampling | Use a multimeter to measure external voltage and compare. |
6 | High-Voltage Interlock Detection | After connecting all connectors of the battery pack, detect BMS status and continuity of interlock lines. |
7 | Internal Resistance Test | Test PACK AC internal resistance and compare with specification values. |
8 | CAN Terminal Resistance | Detect CAN terminal resistance of the battery assembly. |
9 | CAN Communication Function | Detect transmission and status of BMS three-channel CAN. |
10 | Fast Charging Port Temperature Test | Detect static temperature difference of the battery assembly. |
11 | Inlet/Outlet Temperature Test | Determine temperatures of inlet and outlet. |
12 | AC Charging CC Signal | Simulate resistance value RC, detect resistance of battery assembly BMS, and feedback information. |
13 | DC Charging CC2 Signal | Simulate resistance value RC, detect resistance of battery assembly BMS, and feedback information. |
14 | Relay Function Test | Detect status and combined control circuits of relays inside the battery PACK, such as fast charging, slow charging, heating, main positive, and main negative. |
15 | Sleep Current Detection | Send command, BMS enters sleep mode, and obtain sleep current. |
16 | Wake-Up Pin Detection | Detect wake-up function of the battery pack. |
17 | Y Capacitor Test | Test capacitance value between total positive (total negative) of PACK and housing. |
18 | X Capacitor Test | Read BMS relay control state and configure discharge resistance. |
19 | Short Circuit Detection | Measure short circuit conditions between positive/negative terminals of each high-voltage port of the Pack and the housing (ground), and record resistance values. |
20 | Static Cell Voltage and Voltage Difference Test | Read maximum and minimum voltages of all cells and calculate the difference ΔU. |
21 | Static Cell Temperature and Temperature Difference Test | Read maximum and minimum temperatures of all cells and calculate the difference. |
22 | Software Version Number Reading | Read software version number via diagnostic command. |
| Industry Category | Measurement-Analysis-Instruments |
|---|---|