China 3CF Certified Vertical Single (Multi) Stage Fire Pump - China Supplier
China 3CF Certified Vertical Single (Multi) Stage Fire Pump - China Supplier China 3CF Certified Vertical Single (Multi) Stage Fire Pump - China Supplier China 3CF Certified Vertical Single (Multi) Stage Fire Pump - China Supplier China 3CF Certified Vertical Single (Multi) Stage Fire Pump - China Supplier China 3CF Certified Vertical Single (Multi) Stage Fire Pump - China Supplier

3CF Certified Vertical Single (Multi) Stage Fire Pump

Price:Negotiable
Industry Category: Machinery
Product Category:
Brand: 上海三利给水设备有限公司
Spec: 上海三利给水设备有限公司


Contact Info
  • Add:万祥镇, Zip: 200000
  • Contact: 叶志通
  • Tel:18590330992
  • Email:

Other Products

Description
Additional Information

〖〖sanli〗〗Complete CCCF Certification for Fire Protection

Vertical Single/Multi-Stage Fire PumpsFull Range of Certified Specifications, Wide Selection

All Have One-to-One CCCF Certification

Manufacturing Fire Pump Series Products


I. (sanli) XBD-L Type Vertical Fire Pump Product Overview:
The XBD-L type vertical fire pump is used for conveying clean water without solid particles and liquids with physical and chemical properties similar to water. It is mainly used for boosting water supply in fire protection system pipelines, and is also suitable for industrial and urban water supply and drainage, high-rise building booster water supply, long-distance water delivery, heating, bathroom, boiler hot and cold water circulation, booster air conditioning refrigeration system water supply, and equipment matching. The performance and technical conditions of the XBD-L type fire pump unit produced by (sanli) comply with the requirements of the newly promulgated GB6245-1998 "Fire Pump Performance Requirements and Test Methods" standard. The product has been tested and qualified by the Fire Equipment Quality Inspection Center and has obtained the Product Certification Certificate, namely the CCCF Certificate (Fire Product 3C Certificate). (sanli) products are all designed and optimized using computers, with the company's technical strength, rich production experience, and complete testing methods.

II. (sanli) XBD-L Type Vertical Fire Pump Product Features:

1. Compact structure, small size, and beautiful appearance. Its vertical structure determines a small installation area, with the center of gravity on the pump foot, thus enhancing the pump's operational stability and service life.
2. Smooth operation, low noise, and high component concentricity.
3. The shaft seal uses mechanical seals, which are wear-resistant, leak-free, and have a long service life.
4. The pump inlet and outlet are on the same horizontal axis, with the same caliber specifications, facilitating pipeline connection and easy installation and disassembly.
5. Easy maintenance; there is no need to disassemble the pipeline. Simply remove the pump cover nut and take out the motor and transmission components for maintenance.

III. (sanli) XBD-L Type Vertical Fire Pump Technical Parameters:

Flow rate: 5-100 L/S;
Pressure: 0.10-1.25 MPa;
Power: 1.1-250 KW;
Speed: 980-2900 r/min;
Caliber: φ50-φ300;
Temperature range: ≤80°C.

IV. (sanli) XBD-L Type Vertical Fire Pump Model Significance:

62

Type

Flow Q
L/S

Pressure P
MPa

Speed
r/min

Matching Power N
KW

Efficiency η
%

Required NPSH
NPSHr m

Weight
kg

XBD3.2/5-65L-160

5

0.32

2900

4

63

3

71

XBD5/5-65L-200

5

0.5

2900

7.5

60

3

XBD8/5-65L-250

5

0.8

2900

15

55

3

166

XBD12.5/5-65L-315

5

1.25

2900

30

40

3

305

XBD3.2/10-80L-160

10

0.32

2900

7.5

71

3.5

97

XBD5/10-80L-200

10

0.5

2900

15

68

3.5

158

XBD8/10-80L-250

10

0.8

2900

22

62

3.5

235

XBD12.5/10-80L-315

10

1.25

2900

37

55

3.5

350

XBD3.2/25-100L-160

25

0.32

2900

15

76

4.5

176

XBD5/25-100L-200

25

0.5

2900

22

75

4.5

235

XBD8/25-100L-250

25

0.8

2900

37

69

4.5

410

XBD12.5/25-100L-315

25

1.25

2900

75

67

3.5

710

XBD3.2/40-125L-160

40

0.32

2900

22

75

4

255

XBD5/40-125L-200

40

0.5

2900

37

78

4

430

XBD8/40-125L-250

40

0.8

2900

55

77

4

600

XBD12.5/40-125L-315

40

1.25

2900

90

75

4

905

XBD3.250/150L-315

50

0.32

1480

30

78

4.5

485

XBD5/50-150L-400

50

0.5

1480

45

75

4.5

520

XBD3.2/100-200L-315

100

0.32

1480

55

80

4.5

810

XBD5/100-200L-400

100

.5

1480

75

81

4.5

890



V. (sanli) XBD-L Type Vertical Fire Pump Installation Instructions:

1. During installation, the weight of the pipeline should not be borne by the pump, otherwise it may damage the water pump;

2. The pump and motor are an integrated structure, calibrated by the manufacturer before leaving the factory, so no adjustment is needed during installation, making it very convenient;

3. Before installing the pump, carefully check the pump flow channel for any hard objects that may affect the pump's operation (such as stones, iron sand, etc.) to avoid damaging the flow components during operation;

4. During installation, the anchor bolts must be tightened, and the pump should be inspected periodically to prevent loosening, to avoid severe vibration during startup that may affect performance;

5. For convenient maintenance and safety, install a regulating valve on the inlet and outlet pipelines of the pump and a pressure gauge near the inlet and outlet. For high head, to prevent water hammer, a check valve should be installed before the outlet gate valve to handle sudden power loss and other power failure accidents, ensuring the pump operates under suitable conditions and extending its service life;

6. For applications with suction head, a bottom valve should be installed, and the inlet pipeline should not have too many bends. There should be no water or air leakage to avoid affecting the pump's suction performance;

7. To prevent impurities from entering the pump and blocking the flow channel, affecting performance, install a filter before the pump inlet;

8. Before installing the pipeline, rotate the pump's rotor components. There should be no friction or jamming. Otherwise, disassemble the pump to check the cause. 

VI. (sanli) XBD-L Type Vertical Fire Pump Startup and Shutdown:

(I) Pre-startup preparation
1. Turn the motor fan by hand; the impeller should not jam and should rotate flexibly.
2. Open the inlet valve and the exhaust valve to fill the entire pump cavity with liquid, then close the exhaust valve.
3. Rotate the pump shaft by hand to allow lubricant to enter the mechanical seal end face.
4. Jog the motor to confirm the correct rotation direction.

(II) Startup and operation
1. Fully open the inlet valve and close the discharge pipeline valve.
2. Turn on the power. After the pump reaches normal speed, gradually open the discharge pipeline valve and adjust to the required operating conditions.
3. Monitor instrument readings and check the shaft seal leakage. Normal mechanical seal leakage is ≤3 drops/minute. Check the motor and bearing temperature rise ≤70°C. If any abnormalities are found, handle them promptly.
(III) Shutdown
1. Gradually close the discharge pipeline valve and cut off the power.
2. Close the inlet valve.
3. If the ambient temperature is below 0°C, drain the liquid from the pump to avoid freezing and cracking.
4. If the pump is out of service for a long time, disassemble and clean it, and store it properly.

VII. (sanli) XBD-L Type Vertical Fire Pump Maintenance:

(I) Maintenance during operation
1. The inlet pipeline must be filled with liquid. Do not allow the pump to operate under cavitation conditions for extended periods.
2. Regularly check the motor current value; it must not exceed the motor's rated current.
3. After long-term operation, due to mechanical wear, if the unit's noise and vibration increase, stop the pump for inspection. Replace worn parts. The unit's major overhaul period is generally one year.
(II) Mechanical seal maintenance
1. The mechanical seal lubrication should be clean and free of solid particles.
2. Do not allow the mechanical seal to operate under dry grinding conditions.
3. Before starting, rotate the pump (motor) a few turns to avoid sudden startup damaging the seal ring.
4. Allowable seal leakage is 3 drops/minute. If exceeded, perform maintenance.


〖〖sanli〗〗

Buy fire pumps directly from the manufacturer for first-hand prices, excellent quality, and peace of mind

The above is for reference only; please contact us for specific prices



Industry Category Machinery
Product Category
Brand: 上海三利给水设备有限公司
Spec: 上海三利给水设备有限公司
Stock:
Origin: China / Shanghai / Pudongxinqu
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192