China The line temperature status of the power transmission line temperature measuring fixture device is clear at a glance. - China Supplier
China The line temperature status of the power transmission line temperature measuring fixture device is clear at a glance. - China Supplier China The line temperature status of the power transmission line temperature measuring fixture device is clear at a glance. - China Supplier China The line temperature status of the power transmission line temperature measuring fixture device is clear at a glance. - China Supplier

The line temperature status of the power transmission line temperature measuring fixture device is clear at a glance.

Price: 35000
Industry Category: Safety & Security/Surveillance Equipment & Systems/Other Surveillance Equipment & Systems
Product Category:
Brand: 特力康
Spec: TLKS-PMG-TP


Contact Info
  • Add:深圳市龙岗区龙岗街道清风大道39号精密达产业园C栋C-9楼, Zip: 518116
  • Contact: 李女士
  • Tel:13682351635
  • Email:1920671927@qq.com

Other Products

Description
Additional Information

Product Aliases: Transmission Line Temperature Monitoring Device, Overhead Line Wireless Temperature Measuring Device, Transmission Line Temperature Measuring Clamp Device, Online Line Monitoring System - Line Temperature Monitoring System, Transmission Line Fitting Temperature Measuring Device

Transmission Line Temperature Measuring Clamp Device (TLKS-PMG-TP) is an intelligent monitoring device specially developed for heat prevention and control of high-voltage transmission lines. It mainly conducts all-weather online collection and monitoring of temperature changes at key parts such as conductors, connecting fittings, and clamps. Relying on contact digital temperature measurement technology and wireless transmission technology, the device can realistically capture abnormal temperature rises caused by line overload, joint loosening, and equipment aging, and automatically output early warning signals, solving the pain points of traditional manual patrol inspection that cannot monitor line temperature in real time and detect problems with delay. It is a core intelligent operation and maintenance device ensuring the long-term stable operation of high-voltage transmission lines. Its main functions and technologies are as follows:

Working Principle

Transmission Line Temperature Measuring Clamp Device (TLKS-PMG-TP) adopts a three-level monitoring architecture of front-end sensor collection, wireless transmission, and back-end analysis. High-precision temperature sensors deployed at line conductors and clamp joints can realistically and accurately collect surface temperature data of the equipment, and transmit the original data to the terminal host for summary processing via wireless communication. The processed standardized status data is uploaded to the monitoring center platform in real time via a communication network. The system can intelligently judge the equipment operating status according to the preset temperature threshold. Once abnormal temperature rise or over-temperature operation is monitored, it will immediately trigger an early warning prompt, helping operation and maintenance personnel accurately locate fault points and carry out maintenance and rectification in a timely manner, effectively avoiding various safety accidents caused by line overheating.

Core Functions

1.Potential Equalization Anti-interference Design: The shell of the temperature measuring device and the conductor adopt a potential equalization structure design, which can effectively resist electromagnetic interference from high-voltage lines, ensure the accuracy and stability of temperature measurement data, and adapt to the complex operating environment of high-voltage lines.

2.Accurate Temperature Collection: It can independently sense and accurately collect real-time temperatures of conductor surfaces, line fittings, and clamp joints, fully covering key positions of the line that are prone to heat.

3.Multi-dimensional Environmental Monitoring (Optional): It can be expanded to carry functions of collecting environmental temperature, air pressure, wind speed, and wind direction, and comprehensively analyze the causes of line temperature rise combined with meteorological data, improving the professionalism of analysis.

4.Timed Automatic Collection: It supports custom collection time intervals, and the device can fully automatically complete temperature data collection, realizing unattended and normalized monitoring.

5.Intelligent Data Operation: It can perform secondary operation analysis on the original collected data, output intuitive and easy-to-understand temperature status data, facilitating operation and maintenance personnel to quickly judge the equipment operating conditions.

6.Large-capacity Cyclic Storage: It has the ability of cyclic data storage, can completely retain temperature status data for at least 30 days, and supports historical data tracing, operating condition review, and operation and maintenance analysis.

7.Remote Debugging and Operation and Maintenance: It can respond to remote control instructions from the back end, enter the remote debugging mode with one click, and synchronously output equipment operation and debugging information, simplifying on-site operation and maintenance processes and reducing operation and maintenance costs.

Partial Technical Parameters

1.Monitoring Method and Principle: Contact temperature measurement, digital temperature measurement;

2.Temperature Measurement Range: -40℃~120℃; ±0.5℃

3.Operating Line Voltage: ≥35KV

4.Clamp Ambient Temperature: -40℃-70℃

5.Equipment Weight: <0.1KG

6.Communication Distance: >500m

Application Value

Transmission Line Temperature Measuring Clamp Device (TLKS-PMG-TP) completely solves the shortcomings of traditional manual patrol temperature measurement such as delay, incomplete coverage, and scattered data. It realizes all-weather, automatic, and accurate monitoring of the temperature of high-voltage line clamps and conductors, transforming line management from post-failure repair to pre-event prediction. Through real-time temperature rise early warning, it can effectively avoid accidents such as line overheating deformation, equipment damage, and line outage, greatly improving the power supply reliability of the high-voltage power grid. At the same time, the device can retain long-term operation data, providing accurate data support for line condition-based maintenance, equipment aging assessment, and power grid load optimal allocation, effectively reducing the intensity of manual pole-climbing patrol inspection and operation risks, reducing power grid operation and maintenance costs, and helping the power grid achieve refined and intelligent operation and maintenance upgrades. The product is customizable. The quoted price is a reference price when the market is currently released, and the actual price is subject to negotiation. If you want to know more product information, please contact Manager Li from Telcom Technology, 1/8/8/2/0/4/7/9/2/3/1, WeChat and QQ are synchronized

Industry Category Safety & Security/Surveillance Equipment & Systems/Other Surveillance Equipment & Systems
Product Category
Brand: 特力康
Spec: TLKS-PMG-TP
Manufacturer: 深圳市特力康科技有限公司
Origin: 114403