China The troubleshooting of distributed fault location systems for transmission lines is more efficient. - China Supplier China The troubleshooting of distributed fault location systems for transmission lines is more efficient. - China Supplier China The troubleshooting of distributed fault location systems for transmission lines is more efficient. - China Supplier

The troubleshooting of distributed fault location systems for transmission lines is more efficient.

Price: ¥120000
Industry Category: Instruments & Meters/Measurement Standards/Electromagnetic Metrology Standards
Product Category:
Brand: 特力康
Spec: TLKS-PMG-DSC


Contact Info
  • Add:C-9/F, Building C, Jingda Industrial Park, No. 39 Qingfeng Avenue, Longgang Street, Longgang District, Shenzhen, Zip: 518116
  • Contact: 李女士
  • Tel:13682351635
  • Email:1920671927@qq.com

Other Products

Description
Additional Information

Product Aliases: Transmission Line Fault Monitoring System, Transmission Line Distributed Fault Location System, Transmission Line Distributed Fault Diagnosis System

Product Model: TLKS-PMG-DSC

Transmission Line Distributed Fault Location System

I. Product Description:

Transmission lines are a vital component of power systems, and their operational status directly impacts the safety and stability of the entire power grid. However, due to factors such as long line lengths, complex environments, and external interference, transmission lines are frequently at risk of faults. Traditional accident investigation methods mainly rely on manual patrols, which not only consume a large amount of manpower and material resources but also have low efficiency. Therefore, our company's Transmission Line Distributed Fault Location System came into being.

II. Working Principle:

Transmission Line Distributed Fault Location System innovatively integrates advanced inductive power-taking technology, realizing continuous autonomous operation without external power supply. This breakthrough significantly reduces the installation complexity and later maintenance costs of the system. The system has high-precision data acquisition capabilities and can accurately capture the power frequency fault current and fault traveling wave current waveform data on the line. These data are like the "fingerprints" of the line's health status, providing a solid data foundation for accurately judging the line's operational status and fault location. The collected key data is transmitted to the background data center in real time through a high-efficiency and stable 4G network channel, ensuring the timeliness and accuracy of data transmission and creating conditions for remote monitoring and analysis. Operation and maintenance personnel can easily access the data center via Internet to observe the dynamic change charts and data analysis of key parameters such as line current in real time. It can intelligently identify potential abnormalities in the line, realizing comprehensive monitoring of the line's health status. Once the system detects any fault signs, it will immediately activate the emergency response mechanism, automatically generate a detailed fault report, accurately mark the fault location information, and send it to the operation and maintenance team quickly through the preset channel. This process greatly shortens the time from fault discovery to response, provides operation and maintenance personnel with valuable "golden repair time", effectively improves the efficiency and accuracy of power grid fault handling, and escorts the stable operation of the power system.

III. Product Functions:

1. Determine the fault interval based on the power frequency fault current

2. Implement precise traveling wave location in the determined fault interval

3. For transmission lines with complex network structures, distributed fault diagnosis devices can be installed at branch points to divide the complex network into some simple single-line structures

4. Identify the causes of faults, realizing the identification of lightning-caused faults and non-lightning-caused faults. At the same time, it can also identify lightning strike on lightning conductors, towers and conductors when lightning strikes do not cause tripping

IV. Technical Parameters:

1. Ambient Temperature: - 40℃ ~ +85℃

2. Ambient Relative Humidity: 0~ 100%RH

3. Atmospheric Pressure: 86kPa ~ 106kPa

4. Storage Temperature: - 40℃ ~ +85℃

5. Wind Speed: 0km/h ~ 100km/h

. Line Load: The normal working current range for the system's coupled power taking 20~ 1000A

7. Compatibility: It can withstand strong electric fields and strong magnetic fields of 500kV and has reliable and stable electromagnetic compatibility capabilities

V. Summary:

Transmission Line Distributed Fault Location System, relying on its intelligent and networked advanced technology, has built a system for comprehensive monitoring of transmission line status and real-time fault response. The system not only has excellent fault detection and precise location capabilities but also provides solid data support and technical backup for the safe and stable operation of the power system. With the vigorous development of smart grid construction, this system will undoubtedly play an increasingly critical role in future power networks, promoting the development of grid management towards more efficient and intelligent directions.

For detailed information about the equipment, contact Ms. Li from Shenzhen Telink Technology Co., Ltd. by phone:

①③⑥⑧②③⑤①⑥③⑤
WeChat/QQ: ①⑨②0⑥⑦①⑨②⑦

Customized products, the quoted price is a reference price range at the time of market release, and the actual price is negotiable.







VI. Notes:

1. During the customization process, pay attention to protecting the intellectual property rights of both parties and avoid infringement risks.

2. Conduct a technical feasibility assessment of the user's customized requirements to ensure that they can be realized and meet the requirements.

3. Regularly perform appearance inspections, performance tests, and cleaning and maintenance of the equipment to discover and solve problems in a timely manner.

4. Before installation, be sure to carefully read the product installation manual and understand the installation steps, required tools, and safety requirements.

5. After installation, perform system debugging and testing to ensure that all functions are normal and data is transmitted accurately.

Industry Category Instruments & Meters/Measurement Standards/Electromagnetic Metrology Standards
Product Category
Brand: 特力康
Spec: TLKS-PMG-DSC
Stock: 888
Manufacturer: 深圳市特力康科技有限公司
Origin: 114403
About Toocle.com -  Toocle Partnership -  Toocle Services -  Toocle Agents
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192
ChatGlobal TChat