China Grounding Cable Box Monitoring Device Safeguards Your Power Safety - China Supplier
China Grounding Cable Box Monitoring Device Safeguards Your Power Safety - China Supplier China Grounding Cable Box Monitoring Device Safeguards Your Power Safety - China Supplier

Grounding Cable Box Monitoring Device Safeguards Your Power Safety

Price: ¥30000
Industry Category: Instruments & Meters/Measurement Standards/Electromagnetic Metrology Standards
Product Category:
Brand: 特力康
Spec: TLKS-PLGD


Contact Info
  • Add:C-9/F, Building C, Jingda Industrial Park, No. 39 Qingfeng Avenue, Longgang Street, Longgang District, Shenzhen, Zip: 518116
  • Contact: 李女士
  • Tel:13682351635
  • Email:1920671927@qq.com

Other Products

Description
Additional Information

Product Aliases: Cable Circulation Online Monitoring Device, High-voltage Cable Grounding Circulation Online Monitoring System

Product Model: TLKS-PLGD

Grounding Cable Box Monitoring Device

I. Product Description:

Grounding Cable Box Monitoring Device is a device specially used for real-time monitoring of the current in the outer sheath of power cables. It is mainly composed of a sheath circulation sensor, a sheath circulation collector and other components. By collecting and analyzing data on cable sheath circulation, it realizes real-time monitoring and fault early warning of cable operation status.

II. Working Principle:

Grounding Cable Box Monitoring Device, as a high-end solution tailored for high-voltage cable lines of 6.6kV and above, integrates core components such as high-precision sheath circulation sensors and high-efficiency data collectors, realizing real-time and precise monitoring of grounding current. With its excellent anomaly detection capability, the system can sensitively capture any potential operational issues. Through preventive monitoring strategies, it builds a solid protective barrier for key assets such as cable lines and their important cross-interconnection lines and grounding wires.

The remote viewing function of this system greatly enhances the convenience of operation and maintenance management, enabling maintenance personnel to access monitoring data anytime and anywhere across geographical restrictions, achieving comprehensive control over the operation status of cables. This intelligent real-time early warning mechanism innovates the traditional manual regular inspection mode, significantly reducing the workload of operation and maintenance personnel and improving work efficiency.

It is particularly worth mentioning that in the face of emergencies such as abnormal current or stolen grounding wires, the system can respond quickly, automatically trigger the alarm mechanism, and accurately indicate the location of the stolen grounding wire, providing a valuable time window for timely response and rapid recovery, and effectively curbing the occurrence of sudden accidents.

By integrating precise measurement technology with intelligent regular inspection functions, the cable sheath circulation online monitoring system not only significantly improves the efficiency of system maintenance, but also ensures the accuracy of maintenance work, providing strong technical support for the safe and stable operation of high-voltage cable lines.

III. Product Functions:

1. Online Monitoring: Real-time monitoring of the waveform and amplitude of the grounding current in the metal sheath of high-voltage cable lines, reducing the workload of inspection personnel and enabling high-precision detection.

2. Automatic Alarm: When the transient increase or sudden decrease of grounding current to zero occurs, the alarm function will be automatically triggered. ;

3. Cable Anti-theft Monitoring: After grounding wires are stolen, the system will automatically alarm and inform the location of the stolen grounding wire. ;

4. System Self-diagnosis: Real-time detection of faults in the system itself, and uploading the results to the monitoring platform. ;

5. Remote Viewing: Real-time monitoring data can be sent to maintenance personnel's handheld devices via 2G/3G/4G network. ;

6. Information Recording and Analysis: Recording measurement data, fault records and other related parameters, providing intuitive charts such as curves and bar graphs, and statistical reports (weekly, monthly, quarterly, half-yearly, annual). (周、月、季、半年、年);

7. Solar-powered, with CT power-taking support, meeting the power supply needs of complex on-site environments.

IV. Technical Parameters:

1. Sensitivity: ≤±0.1A

2. Measurement Range: Not less than 0-300A/50Hz

3. Maximum Measurement Deviation: Standard reading ×1% + 0.5A

4. Sensor Type: Clamp-on split-core sensor is used.

5. Insulation Isolation Level: Not less than DC10KV/1 minute

6. Enclosure Material: Corrosion-resistant and eddy current-free material is adopted.

7. Protection Grade: Complies with the IP68 requirements for enclosure protection grade specified in GB4208.

V. Summary:

In summary, Grounding Cable Box Monitoring Device has important application value in modern power systems. By real-time monitoring and early warning of changes in cable sheath circulation, it can effectively prevent cable faults, improving the power supply reliability and safety of power systems.

For details about the equipment, please contact Ms. Li from Shenzhen Telink Technology Co., Ltd. by phone:

13682351635; QQ: 1920671927

Customized products, the quoted price is a reference range price at the time of current market release, and the actual price is subject to negotiation.

VI. Notes:

1. During the customization process, pay attention to protecting the intellectual property rights of both parties and avoid infringement risks.

2. Conduct a technical feasibility assessment of the user's customized requirements to ensure that they can be realized and meet the requirements.

3. Regularly conduct appearance inspection, performance testing and cleaning and maintenance of the equipment, and discover and solve problems in a timely manner.

4. Before installation, be sure to carefully read the product installation manual and understand the installation steps, required tools and safety requirements.

5. After installation, conduct system debugging and testing to ensure that all functions are normal and data is transmitted accurately.

Industry Category Instruments & Meters/Measurement Standards/Electromagnetic Metrology Standards
Product Category
Brand: 特力康
Spec: TLKS-PLGD
Stock: 888
Manufacturer: 深圳市特力康科技有限公司
Origin: 114403
About Toocle.com -  Toocle Partnership -  Toocle Services -  Toocle Agents
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192
ChatGlobal TChat