Machine Vision System IO Input Output IO Control Module
Contact Info
- Add:深圳市宝安区沙井街道衙边社区南亭路56号1栋1323, Zip:
- Contact: 肖昆
- Tel:13798435874
- Email:xiaok221@163.com
Other Products
I. Module Introduction
1. Integrated four-channel digital light source control with software-adjustable brightness
2. Integrated 7 high-speed inputs, 1 encoder function, and 12 DO outputs
3. Built-in 12V DC power output for camera power supply
4. External camera trigger/software trigger switchable via software
5. External camera trigger wiring requires no external power supply; simply connect the camera's trigger cables as required
II. Technical Parameters and Installation Dimensions
Operating power supply: DC 24V
Output power
Operating temperature: -20℃ to 50℃
Storage temperature: -30℃ to 70℃
Humidity range: <90%
Installation dimensions
III. Interface Terminal Circuit and Function Definitions
1. 12V Power Output: 4 groups of 12V power output, positive on top and negative on bottom (for camera power supply)
2. External Trigger Output Port Definitions (External power input prohibited)
According to actual port order/Port wiring must not be reversed top to bottom
Port | Camera 4 External Trigger | Camera 3 External Trigger | Camera 2 External Trigger | Camera 1 External Trigger |
Top | T4+ | T3+ | T2+ | T1+ |
Bottom | T4- | T3- | T2- | T1- |
3. Light Source Output Port Definitions (External power input prohibited)
According to actual port order/Port wiring must not be reversed top to bottom
Port | Channel 4 | Channel 3 | Channel 2 | Channel 1 |
Top | L4+ | L3+ | L2+ | L1+ |
Bottom | L4- | L3- | L2- | L1- |
4. IN1-IN8 Input Port Definitions
According to actual port order, inputs can be triggered by either high level or low level, with each channel independently input.
1. Low-level trigger wiring method, internally bidirectional optocoupler, reversible connection
Port | 4 | 3 | 2 | 1 | 8 | 7 | 6 | 5 |
Top | IN4 | IN3 | IN2 | IN1 | Encoder | IN7 | IN6 | IN5 |
Bottom | 24V | 24V | 24V | 24V | 24V | 24V | 24V | 24V |
2. High-level trigger wiring method, internally bidirectional optocoupler, reversible connection
Port | 4 | 3 | 2 | 1 | 8 | 7 | 6 | 5 |
Top | 0V | 0V | 0V | 0V | 24V | 0V | 0V | 0V |
Bottom | IN4 | IN3 | IN2 | IN1 | Encoder | IN7 | IN6 | IN5 |
IN1 | Trigger photo terminal 1 | When an IN signal is input, the module executes the corresponding IN transaction process. Each IN transaction process is set in the module parameter setting software interface. |
IN2 | Trigger photo terminal 2 | |
IN3 | Trigger photo terminal 3 | |
IN4 | Trigger photo terminal 4 | |
IN5 | Trigger photo terminal 5 | |
IN6 | Trigger photo terminal 6 | |
IN7 | Trigger photo terminal 7 | |
IN8 | Encoder | Input common terminal must be connected to high level |
5. OUT Output Port Definitions
According to actual port order/Port wiring must not be reversed top to bottom
Port | 12 | 11 | 10 | 9 | ----- | 4 | 3 | 2 | 1 |
Top | OUT12 | OUT11 | OUT10 | OUT9 | ----- | OUT4 | OUT3 | OUT2 | OUT1 |
Bottom | 0V | ||||||||
Note: 1. OUT numbers correspond one-to-one with the software OUT output settings
2. The bottom row of output terminals must be connected to 0V power supply, do not reverse! Currently only low-level output is supported
IV. IO Module Control Interface: Integrated into vision inspection software
| Industry Category | Machinery |
|---|---|
| Product Category | |
| Brand: | 维视自动化 |
| Spec: | GVS-IO |
| Stock: | 999 |
| Manufacturer: | |
| Origin: | China / Guangdong / Shenshi |