WXZJ-JSY20A Series Intelligent Flow Totalizer
Contact Info
- Add:宜兴市高塍镇江南路126号, Zip: 214214
- Contact: 余丽兰
- Tel:0510-87838003
- Email:wxzjhb@163.com
Other Products
WXZJ-JSY20A Series Intelligent Flow Totalizer
Standard configuration: 3 inputs for flow, temperature, and pressure
Compatible with various differential pressure, pressure, and frequency-type flow sensors
(such as orifice plates, vortex, turbine, etc.)
Measurement range: -999-9999, customizable as needed
Input signals: All types of input signals are supported,
Flow: 4-20mA, 0-10mA, 0-5V, 1-5V, etc.
Frequency signal: PI (frequency range: 0-5000Hz)
Temperature: B, E, J, K, S, T, 0-20mV, 0-100mV,
0-5V, 1-5V, 0-20mA, 4-20mA, Pt100, Cu50, etc.
Pressure: 0-20mA, 4-20mA, 0-5V, 1-5V, etc.
WXZJ-JSY20A Series Intelligent Flow Totalizer
01. Input: 3 channels for flow, temperature, and pressure
02. Output: Standard: 2 relay outputs (normally open by default), USB communication output
Optional: 232 communication output, 485 communication output, analog 4-20mA transmitter output
03. Input signals: All types of input signals are supported,
Flow: 4-20mA, 0-10mA, 0-5V, 1-5V, etc.; Frequency signal: PI (frequency range: 0-5000Hz)
Temperature: B, E, J, K, S, T, 0-20mV, 0-100mV, 0-5V, 1-5V, 0-20mA, 4-20mA, Pt100, Cu50, etc.
Pressure: 0-20mA, 4-20mA, 0-5V, 1-5V, etc.
Note: Other input signals (such as digital input (DI)) or thermocouple types (e.g., PT1000) must be specified when ordering.
04. Measurement range: -999-9999, customizable as needed
05. Accuracy: ±0.2% F·S (i.e., ±0.2% of the full scale of the measurement range)
06. Compatible sensor types: Differential pressure, pressure, and frequency-type flow sensors (e.g., orifice plates, vortex, turbine, etc.), various temperature
sensors and pressure sensors
07. Report types: Daily cumulative report, monthly cumulative report, and annual cumulative report can be viewed on the instrument
08. System parameter settings: The instrument can set management passwords, adjust system time, switch input signals for each channel, customize measurement ranges,
adjust decimal point positions, set measurement error correction values for each channel, and other parameters.
09. Display: Simultaneous display of real-time temperature, pressure, flow, and daily cumulative flow value; split-screen display of temperature, pressure, and flow
curves
10. Display: Blue screen 128×64 dot matrix LCD with LED backlight
11. Power supply: 85-265VAC, 50Hz±5%
12. Power consumption: <8W
13. Power output: 1 set of DC24V output
14. Thermocouple cold junction compensation error: ±1℃
15. Power-off protection: Uses FLASH MEMORY to save setting parameters and historical data. Data can be **saved after power-off; equipped with hardware
clock for accurate operation even after power loss.
16. Operating environment: Temperature: 0-50℃, relative humidity: 0-85% RH
| Industry Category | Environment |
|---|---|
| Product Category | |
| Brand: | |
| Spec: | |
| Stock: | |
| Origin: |