China YPF Diaphragm Pressure Gauge - China Supplier
China YPF Diaphragm Pressure Gauge - China Supplier

YPF Diaphragm Pressure Gauge

Price:Negotiable
Industry Category: Measurement-Analysis-Instruments
Product Category:
Brand: 西仪工控
Spec:


Contact Info
  • Add:陕西省西安市高新区锦业一路72号雄华科技园A座306室, Zip:
  • Contact: 李女士
  • Tel:02981028005
  • Email:xygk029@163.com

Other Products

Description
Additional Information

Product Model: YPF-100A YPF-100B-F YPF-100B YPF-100B-F
Key Features: Diaphragm pressure gauges are suitable for measuring the pressure or negative pressure of various fluid media that are corrosive, viscous, and non-crystallizing or non-solidifying. Different diaphragm materials can be selected based on the corrosion resistance requirements of the measured medium.

Product Application:

Diaphragm pressure gauges are suitable for measuring the pressure or negative pressure of various fluid media that are corrosive, viscous, and non-crystallizing or non-solidifying. Different diaphragm materials can be selected based on the corrosion resistance requirements of the measured medium.

Instruments with stainless steel housings can be used in harsh working environments.
Accuracy Class: 2.5.
Measuring Range: 0-0.06~0-2.5MPa, 0-1.6~0-40KPa.

Diaphragm Pressure Gauge

Suitable for measuring the pressure or negative pressure of various fluid media that are corrosive, non-solidifying, or non-crystallizing.

Corrosion resistance depends on the diaphragm material.

Stainless steel corrosion-resistant diaphragm pressure gauges feature pressure-conducting systems and housings made of stainless steel, offering strong corrosion resistance. They are mainly used in chemical, petroleum, and textile industries for measuring small pressures of gases and liquids, especially suitable for measuring small pressures of highly corrosive and viscous media (non-solidifying, non-crystallizing).

Vibration-resistant diaphragm pressure gauges are filled with damping fluid and equipped with buffer devices, providing excellent vibration resistance. They can perform stable measurements in environments with strong pulse changes in pressure, pressure shocks, frequent sudden unloading in production processes, and high environmental vibration.

Corrosion-resistant and vibration-resistant diaphragm pressure gauges combine the characteristics of both corrosion-resistant and vibration-resistant diaphragm pressure gauges.

Diaphragm Pressure Gauge Structure Principle:

The instrument consists of a measuring system (including flange接头, corrugated diaphragm), transmission指示 mechanism (including connecting rod, gear transmission mechanism, pointer, and dial), and housing (including case and bezel). The housing is splash-proof and offers good sealing, protecting the internal mechanism from contamination.

The operating principle is based on the deformation of the elastic element (diaphragm in the measuring system). Under the pressure of the measured medium, the diaphragm undergoes corresponding elastic deformation—displacement—which is transmitted and amplified by the connecting rod组 through the transmission mechanism. The measured value is indicated on the dial by the pointer fixed to the gear.

Technical Specifications:

Accuracy Class: 2.5

Operating Environment Temperature: -40~+70°C; Relative Humidity ≤90%

Temperature Effect: When operating temperature deviates from 20±5°C, the additional temperature error is ≤0.04%/°C

Operating Position: Vertical installation

Housing Protection等级: IP64

Scale Range, Dimensions, and Weight

ModelScale RangePressure Part Size D1Case Outer Diameter DWeight kg
YPF-100A0~0.06, 0~0.1, 0~0.16, 0~0.25, 0~0.4,
0~0.6, 0~1, 0~1.6, 0~2.5, -0.1~0,
-0.1~0.06, -0.1~0.15, -0.1~0.3, -0.1~0.5,
-0.1~0.9, -0.1~1.5, -0.1~2.4MPa
φ85φ1001.6
YPF-100B
YPF-100B-F
φ115


YPF-150Aφ85φ1501.8
YPF-150B
YPF-150B-F
φ115


YPF-100B
YPF-100B-F
0~1.6, 0~2.5, 0~4, 0~6, 0~10,
0~16, 0~25, 0~40*
-1.6~0, -2.5~0, -4~0, -6~0, -10~0,
-16~0, -25~0, -40~0*
-0.8~0.8, -1.2~1.2, -2~2, -3~3, -5~5,
-8~8, -12~12, -20~20*KPa
φ160φ1002.9
YPF-150B
YPF-150B-F
φ160φ1503.2

* For 0~40, -40~0, ±20KPa specifications, pressure part size D1 is φ85.

◆Advantages and Disadvantages

Advantages: 1. Good overload performance; 2. Linearity; 3. Suitable for measuring absolute pressure, differential pressure; 4. Compact size, moderate price; 5. Can be used for measuring viscous and slurry media.

Disadvantages: 1. Poor vibration and shock resistance; 2. Difficult maintenance; 3. Lower pressure measurement range.

Calibration Equipment:

1. Requirements for Standard Devices

The maximum permissible error absolute value of the standard device should be no greater than 1/4 of the maximum permissible error absolute value of the diaphragm pressure gauge.

2. Selection of Calibration Devices for Diaphragm Pressure Gauges

Pressure calibrators or vacuum calibrators can be selected.

Calibration Items:

Indication error, hysteresis error, light tap displacement, and pointer rotation smoothness.

Calibration Methods:

1. Method for indication error calibration: The indication calibration of the pressure gauge is performed at the marked scale points. During calibration, pressure is increased (or decreased) steadily. When the indication reaches the upper limit, the pressure source is cut off, and the gauge is pressure-resistant for 3 minutes. Then, pressure is decreased (or increased) steadily in reverse order to re-check the calibration points.

2. Hysteresis error: For the same point during calibration, during pressure increase (or decrease) and decrease (or increase) calibration, the absolute value of the permissible error must comply with regulations.

3. Light tap displacement: For each point during calibration, during pressure increase (or decrease) and decrease (or increase) calibration, the change in indication after lightly tapping the case should not exceed half the absolute value of the permissible error.

4. Indication error: For each calibration point, during pressure increase (or decrease) and decrease (or increase) calibration, the difference between the indication before and after lightly tapping the case and the standard device indication should meet requirements.

Selection of Temperature Coefficient:

When using the formula △=±(δ+k△t), for metal diaphragms, the temperature coefficient k is 0.04%/°C; for coated diaphragms, the temperature coefficient k is 0.06%/°C.

Business Phone
Contact Number 1(029) 8102-8005
Contact Number 2(029) 8113-6005
Business Inquiry180 9252 2930
Product Service135 7149 5999
Technical Support139 9190 0175

Industry Category Measurement-Analysis-Instruments
Product Category
Brand: 西仪工控
Spec:
Stock:
Origin: China / Shaanxi / Xianshi
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192