ECS-7000MD Chilled Water Circulation Pump Unit Energy Saving Controller and Refrigeration Plant Room Cluster Control System
Other Products
Refrigeration Plant Cluster Control SystemDesign Basis
GB50736-2012 "Design Code for Heating, Ventilation and Air Conditioning of Civil Buildings"
GB/150378-2019 "Assessment Standard for Green Building"
GB/T26759-2011 "Technical Specification for Energy-saving Control Devices of Central Air Conditioning Water Systems"
"Green Design Standard for Civil Buildings" JCJ/T229-2010
GB50189-2015 "Energy Efficiency Design Standard for Public Buildings"
GB51348-2019 "Electrical Design Standard for Civil Buildings"
For more product information or pricing, please call our company.
Product Quotation Phone: 152-0290-6680
Please contact Manager Zhang: 152-----02900-----6680
We will wholeheartedly provide you with project drawing design optimization and configuration plan quotations!!!
Refrigeration Plant Cluster Control System Introduction
ECS-7000 Chiller Air Conditioning System, where the air conditioning chilled circulating water is cooled and refrigerated by the chiller. The chilled water supply is distributed via a water separator to air conditioning users for cooling, and the return water is collected via a water collector and returned to the chilled water system circulation pump for cycling. The system is equipped with a circulating water makeup device.
The system consists of a cluster main control cabinet: equipment energy-saving controllers, sensors, transmitters, and actuators.
Refrigeration Plant Cluster Control System Monitoring and Control Functions
1) Control of the opening and closing of relevant electric butterfly valves on the chilled water pipeline network of the refrigeration units.
2) Monitoring of chilled water supply and return temperature, pressure, and flow.
3) Monitoring of the operation, fault, and manual/automatic status of refrigeration units and chilled water circulation pumps.
4) Monitoring and control of secondary chilled water pumps/supply and return water temperature, pressure, and flow.
5) Monitoring of operation, fault, and manual/automatic status, and start/stop control of refrigeration units, chilled water circulation pumps, cooling water circulation pumps, and cooling towers.
6) Monitoring of the operation and fault status of constant pressure makeup water pumps.
7) Monitoring of operation, fault, and manual/automatic status, and start/stop control of heat exchange hot water pumps.
8) Monitoring of primary/secondary side supply and return water temperature and pressure for heat exchange.
9) Connection to the system via a gateway through the reserved communication interface of the boiler (requires manufacturer provision).
10) Monitoring of the operation and fault status of boiler hot water circulation pumps.
Refrigeration Plant Cluster Control System Equipment
ECS-7000MZK Main Controller
ECS-7000MLS Refrigeration Unit Energy-saving Controller
ECS-7000 MD Chilled Water Circulation Pump Group Energy-saving Controller
ECS-7000MQ Cooling Water Circulation Pump Group Energy-saving Controller
ECS-7000 MR Hot Water Circulation Pump Group Energy-saving Controller
ECS-7000 MB Makeup Water Pump Group Energy-saving Controller
ECS-7000 MUD Universal Energy-saving Controller
ECS-7000MT Cooling Tower Fan Energy-saving Controller
ECS-7000WG Gateway
YK-FG Water Flow Switch
YK-JH08 Switch
ECS-7000S/Q System Host and Software
| Industry Category | Machinery |
|---|---|
| Product Category | |
| Brand: | ECS-7000MD |
| Spec: | ECS-7000MD |
| Stock: | 233 |
| Manufacturer: | |
| Origin: | China / Shaanxi / Xianshi |