G.I-K Energy-saving Controller for Feedwater Pump
G.I-K Technical Parameters of Feedwater Pump Energy-saving Controller
Dedicated integrated controller, rail-mounted installation, external energy efficiency monitoring module and three-phase mutual inductor, motor drive device and three-phase integrated mutual inductor. Equipped with functions such as intelligent power distribution, intelligent control of hot water pumps, energy efficiency optimization, and equipment self-check. It cooperates with the KB0 control and protection switch in the distribution box to provide comprehensive electromechanical integration functions including phase loss, phase break, overvoltage, undervoltage, overcurrent, undercurrent, short circuit, leakage, and three-phase imbalance protection. Communication interfaces include both RS485 and LAN, serving as a protocol gateway for integrated open access to communication terminals near the electrical control terminal; high-definition touch screen is mounted outside the distribution box door; features an integrated anti-counterfeiting QR code, supporting QR code scanning to monitor the entire lifecycle status of the equipment.
Product Models
YK-BA6201 Air Conditioning/Fresh Air Unit Energy-saving Controller
YK-BA6203 Elevator Energy-saving Controller
YK-BA6204 Fan/Water Pump Energy-saving Controller
DXC-27-0/2 Drainage (Sewage) Pump Unit
DXC-28-0/2F Variable Frequency Constant Pressure Feedwater Pump
DXC-30-0/1 Air Conditioning Make-up Water Pump
DXC-31-0/1 Fresh Air Conditioning Supply Air Unit
DXC-32-0/1 Constant Air Volume Air Conditioning Supply Air Unit
DXC-33-0/1F Variable Air Volume Air Conditioning Supply Air Unit
DXC-34-0/2 Full-function Air Conditioning Supply Unit
DXC-35-0/2F Full-function Variable Air Volume Air Conditioning Supply and Return Air Unit
DXC-41-0/2 Air Conditioning Chilled/Hot Water Circulation Pump Unit
DXC-42-0/2F Air Conditioning Chilled/Hot Water Variable Frequency Circulation Pump Unit
DXC-43-1/2F Single Heat Exchanger Variable Frequency Circulation Pump Unit
DXC-46-0 Water Intake Pump
DXC-46-1/WG Source Heat Pump Unit
DXC-46-2 Chilled Water Pump Unit
DXC-46-3 Cooling Water Pump Unit
DXC-46-4 Cooling Tower Fan
RXKQ NH Energy Efficiency Management Energy-saving Controller
RXKQ PD Power Distribution Room Safety Monitor
G.AQ Cooling Pump Energy Efficiency Controller
G.AD Chilled Water Pump Energy Efficiency Controller
G.AF Cooling Fan Energy Efficiency Controller
G.AQ Cooling Pump Energy Efficiency Controller
G.AD Chilled Water Pump Energy Efficiency Controller
G.L Air Conditioning Zoning Controller
G.REAL-A Air Conditioning System Energy Efficiency Controller
G.H Variable Frequency Soft Switcher
G.AC Air Conditioning System Data Collector
G.AY-B Garage CO Fan Sub-controller
G.AY-A Garage CO Fan Main Controller
G.AX-A Air Conditioning Unit Main Energy Efficiency Controller
G.AX-A Air Conditioning Unit Energy-saving Controller
G.AX-B Fresh Air Unit Energy-saving Controller
G.AX-B Supply Fan Energy-saving Controller
G.AX-B Exhaust Fan Energy-saving Controller
G.I-P Drainage Pump Energy-saving Controller
G.I-P Submersible Sewage Pump Energy Efficiency Controller
G.I-K Feedwater Pump Energy-saving Controller
G.IT Elevator Energy-saving Controller
G.AD Chilled Water Pump Energy-saving Controller
G.AQ Cooling Pump Energy-saving Controller
G.AF Cooling Tower Energy-saving Controller
G.AS Air Conditioning Terminal Energy Efficiency Controller
G.REAL-AX-B Fresh Air Unit Controller
G.AZ Positive Pressure Supply Fan Controller
AT-AC1100-LRY Cooling and Heat Source Central Control Module
AT-AC1100-LDS Chilled Water Circulation Pump Control Module
AT-AC1100-LQS Cooling Water Circulation Pump Control Module
AT-AC1100-LQT Cooling Tower Control Module
AT-AC1100-RSB Hot Water Circulation Pump Control Module
Design Basis
"Code for Electrical Design of Civil Buildings" GB 51348-2019
"Standard for Design of Intelligent Buildings" GB 50314-2015
"Code for Quality Acceptance of Intelligent Building Engineering" GB 50339-2013
"Code for Design of Generic Cabling System Engineering" GB50311-2016
"Code for Acceptance of Generic Cabling System Engineering" GB/T50312-2016
"Code for Design of Lightning Protection of Buildings" GB50057-2010
"Basic and Safety Principles for Man-Machine Interface, Marking and Identification - Identification of Equipment Terminals and Conductor Terminations" GB/T4026-2019
"Standard for Quality Inspection and Assessment of Automation Instrumentation Installation Engineering" GBJ131-90
"Code for Construction and Acceptance of Automation Instrumentation Engineering" GB50093-2013
"Code for Quality Acceptance of Building Electrical Engineering" GB50303-2015
Main Standard Atlases Selected:
"Design and Installation of Building Equipment Management System" 19×201
"Common Data for Building Electrical Engineering" 19DX101-1
"Energy-saving Control and Management of Building Equipment" 09CDX008-3
"Indoor Pipeline Installation" (2004 Bound Volume) 19DX101-1
"Safety Requirements and Test Methods for Security Alarm Equipment" GB16796-2009
"Environmental Adaptability Requirements and Test Methods for Security Alarm Equipment" GB/T15211-2013
For Detailed Consultation
Manager Zhang: 15202906680
Welcome to call for consultation, we are wholeheartedly at your service!
| Industry Category | Machinery |
|---|---|
| Product Category | |
| Brand: | 其他品牌 |
| Spec: | G.I-K |
| Stock: | 393833 |
| Manufacturer: | |
| Origin: | China / Shaanxi / Xianshi |