China Airflow Sieve Analyzer - China Supplier
China Airflow Sieve Analyzer - China Supplier China Airflow Sieve Analyzer - China Supplier China Airflow Sieve Analyzer - China Supplier

Airflow Sieve Analyzer

Price:Negotiable
Industry Category: Measurement-Analysis-Instruments
Product Category:
Brand: 医卡(上海)科技有限公司
Spec: YK-QLS


Contact Info
  • Add:上海市松江区曹农路5弄40号, Zip:
  • Contact: 蒋瑞
  • Tel:15372708335
  • Email:2665202311@qq.com

Other Products

Description
Additional Information

Breaking the Boundaries of Sample Sieving—YK-QLS Air Jet Sieve Analyzer, Offering a New Choice for Your Powder Analysis

The Air Jet Sieve Analyzer meets the basic needs for air jet sieving of certain powders. Place the powder sample to be tested into the instrument, then activate the negative pressure generator and the timer on the touch screen to perform air jet sieving on the powder. The Air Jet Sieve Analyzer implements the air jet sieving theory of classification before sieving and can also determine the percentage of particle size limits.

It fulfills the basic requirements for air jet sieving of certain powders. Place the powder sample to be tested into the instrument, activate the negative pressure generator and the timer on the touch screen, and perform air jet sieving on the powder.

The instrument is equipped with an imported electronic vortex generator from the United States. In coordination with the negative pressure generator, the Air Jet Sieve Analyzer produces a precise and sensitive negative pressure air vortex. This vortex drives the powder upward through the nozzle, colliding with the sieve lid to remove agglomerated particles. The powder is re-sucked by the vortex onto the standard test sieve in order of size. Smaller particles pass through the sieve mesh and are stored in the negative pressure generator or sample collector, while larger particles remain on the test sieve. Throughout the process, the electronic vortex generator controls the three-dimensional movement of powder particles by size, realizing the air jet sieving theory: classification before sieving. By replacing test sieves with different mesh sizes for sequential sieving, the percentage of particle size limits is ultimately determined.

In the field of powder analysis and sieving, accurate classification and sieving processes are crucial steps to ensure reliable analytical data. To meet the needs of research institutions, testing laboratories, and production applications for particle sieving, Yika (Shanghai) Technology Co., Ltd. has introduced the YK-QLS Air Jet Sieve Analyzer, suitable for particle sieving in the range of 15 micrometers to 5000 micrometers. Analysis and sieving cover materials such as ceramic sand, metal powder, mineral powder, and chemical powders.

It is particularly suitable for sieving fine particles, removing agglomerated particles, and obtaining the percentage of particle size limits.

It provides process support for research, quality testing, raw material development, and other stages.

Main Applications

Particularly suitable for determining particle size and obtaining the percentage of particle size limits of powder samples.

Provides process support for research, quality testing, raw material development, and other stages.

Product Highlights

Touch-operated interface, one-click start of the sieving process, sieving time can be set on the touch screen, and the test can be paused midway.

Real-time airflow pressure display and adjustment, combined with the electronic vortex generator and negative pressure device, enable powder movement in a three-dimensional airflow, more effectively dispersing agglomerated particles.

High technical precision: measurement range of 15–5000 µm; compatible with 10–800 mesh sieves; repeatability error less than 1%.

Precise structure: features forward and reverse rotation, precision stepper motor, and data printing support for easy process recording and traceability.

Compact and reliable: small size, suitable for use in conventional laboratory environments.

Why Choose YK-QLS?

If you encounter the following challenges in sample sieving, YK-QLS may be an option to consider.

Difficulty in sieving fine powders, sieve mesh easily clogged.

Significant agglomerated particles affecting sieving accuracy.

Wide particle size range or need to obtain particle distribution data.

Pursuit of simple operation, controllable process, and recordable data.

Technical Parameters of the Air Jet Sieve Analyzer:

1. Model: YK-QLS

2. Rotation Speed: 0-50 rpm

3. Measurement Range: 15-5000 µm

4. Recommended Sample Quantity per Test: <100g

5. Maximum Sample Quantity: 200g

6. Vacuum Degree: 0~10 kPa

7. Sieving Time: 0~9999 min

8. Sieve Mesh: 10~800 mesh

9. Data Printing: Supported

10. Forward and Reverse Rotation: Supported

11. Measurement Accuracy: <1%

12. Repeatability Error: <1%

13. Power/Power Consumption: 220V 50Hz/180 W

14. Dimensions: 463*338*383 mm

Configuration List of the Sieve Analyzer:

1. Main Unit: 1

2. Pressure Generator: 1

3. Transparent Lid: 1

4. Brush: 1

5. Fuse: 3

6. Power Cord: 1

7. Sample Collector: 1 set

Industry Category Measurement-Analysis-Instruments
Product Category
Brand: 医卡(上海)科技有限公司
Spec: YK-QLS
Stock: 1000
Manufacturer:
Origin: China / Shanghai / Xingqu
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192