Dual-Clamp Digital Phase Volt-Ampere Meter
Contact Info
- Add:扬州宝应柳堡工业集中区范柳路55号, Zip: 225800
- Contact: 费苏强
- Tel:86-0514-88557066
- Email:yzkedq@163.com
Other Products
KETCR4000 Dual-Clamp Digital Phase Volt-Ampere Meter
I. Product Introduction
The KETCR4000 Dual-Clamp Digital Phase Volt-Ampere Meter is a multifunctional instrument specifically designed for on-site testing, featuring high precision, high stability, low power consumption, and ease of use. It can directly measure AC voltage and AC current without breaking the circuit under test, measure the phase between two voltages, two currents, and between voltage and current. Additionally, it can indirectly measure the power factor and power of the circuit, determine three-phase phase sequence, transformer wiring groups, inductive and capacitive circuits, test secondary circuits and bus differential protection systems, read the phase relationship between various CTs in differential protection, check the correctness of watt-hour meter wiring, and repair line equipment, among other functions.
The KETCR4000 Dual-Clamp Digital Phase Volt-Ampere Meter features an ultra-large LCD display with white backlight, providing clear visibility and an exquisite, luxurious appearance. It uses voltage transformers and current clamps for input, with no high voltage inside the unit. The two input channels are completely isolated, ensuring safety and reliability.
The KETCR4000 Dual-Clamp Digital Phase Volt-Ampere Meter is suitable for use in power, petrochemical, metallurgy, railway, meteorology, industrial and mining enterprises, research institutions, and metrology departments.
II. Product Features
1. Directly measure AC voltage and AC current without breaking the circuit under test, measure the phase between two voltages, two currents, and between voltage and current, determine three-phase phase sequence, transformer wiring groups, inductive and capacitive circuits, test secondary circuits and bus differential protection systems, read the phase relationship between various CTs in differential protection, check the correctness of watt-hour meter wiring, and repair line equipment, among other functions.
2. Use voltage transformers and current clamps for input, with no high voltage inside the unit. The two input channels are completely isolated, ensuring safety and reliability.
3. The current clamp jaws are thin, pointed, and long, making them suitable for measurements in densely wired environments.
4. Test leads are made of specialized power cables, with both spring-loaded plugs and alligator clips insulated for protection.
5. Insulated anti-slip protective sleeve.
6. Ultra-large LCD display with white backlight for clear visibility. High precision, high stability, low power consumption, and ease of use.
III. Technical Specifications
1. Reference Conditions and Operating Conditions
Influencing Factor | Reference Conditions | Operating Conditions | Remarks |
Ambient Temperature | 23℃±1℃ | -10℃~40℃ | |
Ambient Humidity | 40%~60% | <85% | |
Signal Waveform | Sinusoidal Wave | Sinusoidal Wave | β=0.05 |
Signal Frequency | 50HZ±1HZ | 45HZ~65HZ | |
Meter Operating Voltage | 9V±0.1V | 9V±1V | |
External Electric and Magnetic Fields | Should be avoided | ||
Position of Measured Conductor | The measured conductor should be approximately at the geometric center of the clamp jaws | ||
2. Basic Error and Performance Indicators Under Reference Conditions
Category | Range | Resolution | Basic Error |
Voltage | 20V | 0.01V | ±(0.5% of range) |
200V | 0.1V | ||
500V | 1V | ||
Current | 200mA | 0.1mA | ±(0.5% of range) |
2A | 1mA | ||
10A | 10mA | ||
Phase | 0~360° | 1° | ±1° |
Phase error under operating conditions: ±3° for 10mA~20A; ±6° below 10mA
3. General Specifications (KETCR4000 Model)
Function | Direct testing of phase, AC current, AC voltage, AC leakage current, phase sequence; determination of transformer groups, inductive and capacitive circuits; indirect testing of power factor and power |
Power Source | DC9V alkaline dry batteries (1.5V AA×6) |
Power Consumption | Approx. 35mA with backlight on, battery operates continuously for about 40 hours |
Approx. 5mA with backlight off, battery operates continuously for about 300 hours | |
Display Mode | LCD display with blue backlight, suitable for dimly lit environments |
LCD Size | 70mm×62mm |
LCD Display Area | 64mm×54mm |
Meter Dimensions | Length × Width × Thickness: 196mm×92mm×54mm |
Clamp Jaw Dimensions | φ7.5mm×13mm |
Sampling Rate | Approx. 3 times/second |
Ranges | AC Voltage: 0~20V/200V/500V |
AC Current: 0~200mA/2A/10A | |
Phase: 0~360° | |
Amplitude Range of Measured Signals During Phase Measurement | When measuring U1-U2 phase: 30V~500V |
When measuring I1-I2 phase: 10mA~10.00A | |
When measuring U1-I2 or I1-U2 phase: 10V~500V, 10mA~10.00A | |
Data Hold | Press HOLD key during testing to hold data, "DH" symbol displayed |
Auto Power Off | Automatically powers off after approx. 15 minutes to reduce battery consumption |
Voltage Detection | When battery voltage is below 7.8V~8V, low battery symbol is displayed to remind user to replace batteries |
Meter Weight | 1140g (with batteries) |
Test Lead Length | 1.5m |
Current Clamp Cable Length | 2m |
Operating Temperature and Humidity | -10℃~40℃; below 80% Rh |
Storage Temperature and Humidity | -10℃~60℃; below 70% Rh |
Input Impedance | Input impedance for each voltage range: 2MΩ |
Input impedance for U1U2 phase measurement: 40KΩ | |
Withstand Voltage | Between meter circuit and casing: withstands 1000V/50Hz sinusoidal AC voltage for 1 minute; between two voltage input terminals: withstands 500V/50Hz sinusoidal voltage for 1 minute |
Insulation | Between meter circuit and casing, and between two voltage input terminals: ≥10MΩ |
Structure | Double insulation |
Standard Accessories | Main unit: 1 piece; current clamps: 2 pieces; test leads: 4 pieces; aluminum case: 1 piece |
Note: The product is continuously updated and improved during production. The product appearance images are for reference only (subject to the actual product). Changes may be made without prior notice.
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | 凯尔 |
| Spec: | KETCR4000 |
| Stock: | |
| Origin: | China / Jiangsu / Yangzhoushi |