China Concrete mixing station cooling and dust suppression spray equipment, landfill deodorization and dust reduction spray system, waste recycling treatment station dust suppression and dust removal spray machine. - China Supplier
China Concrete mixing station cooling and dust suppression spray equipment, landfill deodorization and dust reduction spray system, waste recycling treatment station dust suppression and dust removal spray machine. - China Supplier China Concrete mixing station cooling and dust suppression spray equipment, landfill deodorization and dust reduction spray system, waste recycling treatment station dust suppression and dust removal spray machine. - China Supplier China Concrete mixing station cooling and dust suppression spray equipment, landfill deodorization and dust reduction spray system, waste recycling treatment station dust suppression and dust removal spray machine. - China Supplier China Concrete mixing station cooling and dust suppression spray equipment, landfill deodorization and dust reduction spray system, waste recycling treatment station dust suppression and dust removal spray machine. - China Supplier China Concrete mixing station cooling and dust suppression spray equipment, landfill deodorization and dust reduction spray system, waste recycling treatment station dust suppression and dust removal spray machine. - China Supplier

Concrete mixing station cooling and dust suppression spray equipment, landfill deodorization and dust reduction spray system, waste recycling treatment station dust suppression and dust removal spray machine.

Price:元15 /米
Industry Category: Machinery
Product Category:
Brand: 陆雄
Spec: LX280


Contact Info
  • Add:山东济南市天桥区济洛路158-70-22, Zip:
  • Contact: 孙
  • Tel:15905312183
  • Email:

Other Products

Description
Additional Information


Concrete Mixing Plant Cooling and Dust Removal Spraying Equipment, Landfill Deodorization and Dust Suppression Spraying, Waste Recycling Station Dust Removal and Suppression Spraying Machine

The spraying system mainly consists of PPR water pipes, straight connectors, tees, elbows, etc., forming an enclosed pipeline for water flow. The water tank provides the water source for spraying, the multi-stage pump supplies the delivery power, and the intelligent controller controls the entire system.

1. Intelligent Controller: Uses digital chip control, integrating automatic control of upper and lower liquid levels and pressure; offers three working modes: automatic, manual, and remote control; includes protection functions such as overload, no-load, phase loss, and ultra-low voltage; features a no-load restart function adjustable from 1 to 240 minutes; has a fault memory function, allowing review of the causes of the last 5 faults; easy installation and simple debugging for enclosure spraying.

2. Multi-stage Pump: Before starting, fill the pump with water; when starting, open the outlet valve to reduce the motor's starting load and prevent motor burnout; when the pump's pressure decreases, reduce the number of paper gaskets between the pump body and cover, as adjusting the pressure too high may burn out the motor.

3. Water Tank: The water tank is equipped with an automatic water level control valve. When the water level in the tank is insufficient, the switch opens to automatically replenish the water source; when the water level reaches a certain height, the control valve automatically closes to stop water replenishment.

Spraying and Mist Spraying;

1. Pipeline Installation on the Enclosure: Set the main water switch at the starting point, with the main pipeline set to 4 meters. Use a tee to connect the water pipes at both ends, insert a mist spray pipe above, and install a straight connector to connect the nozzle to the pipeline. (The distance between mist spray pipes can be set according to actual needs.) Secure the water pipes to the enclosure with clips and screws.

2. Water Pump Installation: First, secure the water pump to the bracket with screws. After connecting the wires, cover the pump with a rain shelter and secure it to the bracket with screws. Wrap the pump joint with raw silk tape, then secure the water pipe to the pump joint with screw clips. The other end of the pump and pipeline joint should also be wrapped with raw silk tape before connecting to the pipeline.

3. The intelligent controller has excellent waterproof settings and only needs to be fixed to the enclosure. The internal wiring of the controller is complete; simply connect the power cord, remote control device wire, water level alarm wire, and water pump power wire.

4. After connecting various controllers to each other, the system is ready for use.

Spraying and Mist Spraying;

1. Pipeline Installation on the Enclosure: Set the main water switch at the starting point, with the main pipeline set to 4 meters. Use a tee to connect the water pipes at both ends, insert a mist spray pipe above, and install a straight connector to connect the nozzle to the pipeline. (The distance between mist spray pipes can be set according to actual needs.) Secure the water pipes to the enclosure with clips and screws.

2. Water Pump Installation: First, secure the water pump to the bracket with screws. After connecting the wires, cover the pump with a rain shelter and secure it to the bracket with screws. Wrap the pump joint with raw silk tape, then secure the water pipe to the pump joint with screw clips. The other end of the pump and pipeline joint should also be wrapped with raw silk tape before connecting to the pipeline.

3. The intelligent controller has excellent waterproof settings and only needs to be fixed to the enclosure. The internal wiring of the controller is complete; simply connect the power cord, remote control device wire, water level alarm wire, and water pump power wire.

4. After connecting various controllers to each other, the system is ready for use.

Precautions for Using Spraying and Mist Spraying

1. Startup: After connecting all enclosure wires, close the air switch, select the working mode, and press the start button to start the water pump. Please be cautious to prevent electric shock!

2. Controller Working Modes: Automatic, Manual, and Remote Control: A. In automatic mode, if the start button is not pressed, the automatic mode light will flash, and the controller will not run automatically. Only after pressing the start button and the automatic mode light stays on will the controller operate automatically. B. In manual mode, press the start or stop button to control the motor's operation. In manual mode, the controller only provides overload and phase loss protection and is not controlled by water level or pressure; no-load protection is not provided.

3. Phase Loss Protection: If any phase of the three-phase power supply is suddenly disconnected, the protector will cut off the water pump's power within 3 seconds.

4. Ultra-Low Voltage Protection: When the grid voltage drops below 300V, the controller will cut off the water pump's power within 20 seconds. The phenomenon will be the voltage and current meters displaying the same value, and the phase loss indicator light will illuminate.

5. Overload Protection: The controller has an inverse time overload protection characteristic, meaning the higher the overload current exceeds the set value, the faster the overload protection will act.

6. Be cautious of water flow and electric shock on the enclosure.

Spraying and Mist Spraying Dismantling Notes;

1. When relocating, be careful not to forcibly pull apart each interface when dismantling the enclosure pipeline, as this may damage the pipe ends and joints!

2. Dismantle the intelligent controller's wiring carefully to avoid disordering the wires and rendering them unusable. Handle the control box gently when moving it; do not throw or drop it!

3. Do not dismantle the system while spraying is in operation!

Daily Maintenance of Spraying;

Regular inspection and maintenance are required to ensure the machinery's long-term safe use.

1. During spraying, strictly follow the operating instructions to prevent misoperation and reduce unnecessary losses.

2. In cold weather, take appropriate measures as per the operating instructions to prevent freezing. If the enclosure spraying is idle for a long time or during winter nights, drain the water from the pipes to prevent freezing.

3. Regularly clean the sludge inside the water pump to avoid it flowing into the clean water tank and clogging the nozzles.

4. Keep the equipment surface clean and sanitary.

5. Before performing any cleaning or maintenance, disconnect the power supply.

6. Frequently check the nozzles and spray holes for blockages to avoid affecting spraying and mist spraying performance.

Shandong Luxiong Environmental Protection Equipment's main products include:

I. Engineering Enclosure Spraying Series (Engineering Enclosures, Construction Barriers, Building Enclosures, PVC Fences, Simple Enclosures, Mobile Enclosures, Subway Construction Enclosure Spraying)

II. Guardrail Net Series (Warehouse Partition Nets, Equipment Protection Nets, Workshop Guardrail Nets, Double Wire Guardrail Nets, Highway Guardrail Nets, Railway Enclosure Nets, Plastic-Coated Wire Meshes, Chain Link Nets, Spraying on Anti-Throw Nets)

III. PVC Guardrail Series (Lawn Guardrails, Garden Guardrails, Flower Bed Fences, Villa Fences, Garden Fences, Spraying on These)

IV. Zinc Steel Fence Series (Road Guardrails, Jing-style Guardrails, Traffic Guardrails, Wall Fences, Wrought Iron Fences, Spraying on These)

Spraying and Mist Spraying After-Sales Service;

The entire machine is covered by a free warranty for one year from the date of purchase. If the enclosure spraying malfunctions and cannot be resolved after checking according to the above troubleshooting steps, please contact us. The entire machine provides lifelong repair services. After the warranty period expires, the company only charges for the cost of parts.

The following situations are not covered by the free warranty service:

1. Self-dismantling of the product;

2. Malfunctions caused by abnormal grid voltage, fire, or use in non-standard environments;

3. Failure to use the product according to the instructions, enclosure spraying label, or other precautions;

4. Other obvious human damage or injuries are not covered by the warranty;

5. The company is not responsible for any losses caused by force majeure factors such as earthquakes or typhoons.

Industry Category Machinery
Product Category
Brand: 陆雄
Spec: LX280
Stock: 100
Manufacturer:
Origin: China / Shandong / Jinanshi
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192