I. Introduction:
The structure of the H61Y high-pressure lift check valve is generally similar to that of a gate valve. Its disc moves up and down along the center line of the channel, with reliable operation, but it has relatively high fluid resistance, making it suitable for applications with smaller diameters. Lift check valves are divided into two types: straight-through and vertical. Straight-through lift check valves can generally only be installed on horizontal pipelines, while vertical lift check valves should generally be installed on vertical pipelines. The disc rotates around a rotating shaft. Its fluid resistance is generally lower than that of lift check valves, making it suitable for applications with larger diameters. For check valves where the disc slides along the vertical center line of the valve body, high-pressure lift check valves can only be installed on horizontal pipelines. For high-pressure small-diameter check valves, the disc can be spherical. The valve body of a butterfly check valve has the same shape as that of a gate valve (it can be used interchangeably with a gate valve), so its fluid resistance coefficient is relatively large. Its structure is similar to that of a gate valve, and the valve body and disc are the same as those of a gate valve. A guide sleeve is machined on the upper part of the disc and the lower part of the valve cover, and the disc guide sleeve can freely move up and down within the valve cover guide sleeve. When the medium flows forward, the disc is opened by the thrust of the medium; when the medium stops flowing, the disc falls onto the valve seat by its own weight, preventing the medium from flowing backward. The direction of the medium inlet and outlet channels of a straight-through butterfly check valve is perpendicular to the direction of the valve seat channel; for vertical lift check valves, the direction of the medium inlet and outlet channels is the same as that of the valve seat channel, and its flow resistance is lower than that of the straight-through type.
II. Installation and Maintenance:
1. Both ends of the valve passage must be plugged, and the valve should be stored in a dry and ventilated room. If stored for a long time, rust prevention should be checked regularly.
2. Before installation, the valve should be cleaned, and defects caused during transportation should be eliminated.
3. During installation, carefully check whether the marks and nameplates on the valve meet the usage requirements.
4. Lift check valves with vertical discs should be installed on horizontal pipelines.
5. Lift check valves with horizontal discs should be installed on vertical pipelines.
6. Do not place any weight on the check valve in the pipeline. Large-sized check valves should be independently supported to avoid being affected by the pressure generated by the pipeline system.
7. When installing the check valve, pay special attention to the flow direction of the medium. The normal flow direction of the medium should be consistent with the direction of the arrow marked on the valve body; otherwise, the normal flow of the medium will be blocked. The bottom valve should be installed at the bottom of the water pump suction pipeline.
8. Straight-through lift check valves should be installed on horizontal pipelines; vertical lift check valves and bottom valves are generally installed on vertical pipelines, and the medium flows from bottom to top.
9. When the check valve closes, water hammer pressure will be generated in the pipeline, which may cause damage to the valve, pipeline or equipment in severe cases, especially for large-diameter pipelines or high-pressure pipelines. Therefore, great attention should be paid when selecting a check valve.
III. Principle and Price:
1. When the medium flows in the specified direction, the disc is opened by the force of the medium. When the medium flows backward, due to the weight of the disc and the reverse force of the medium acting on the disc, the sealing surface of the disc and the valve seat are tightly fitted to close, achieving the purpose of preventing the medium from flowing backward.
2. The sealing surfaces of the valve body and disc are surfaced with stainless steel.
3. The structural length of this valve is in accordance with the provisions of GB12221-1989, and the flange connection dimensions are in accordance with the provisions of JB/T79-1994.
IV. Parts Materials:
Model | Part Name | |||||||
Valve Body | Disc | Spring | Stem | Packing | Pressure Plate | Valve Cover | Lock Nut | |
H61Y-250 H61Y-320 | Carbon Steel | Carbon Steel | Spring Steel | Stainless Steel | Flexible Graphite | Carbon Steel | Carbon Steel | High-quality Carbon Steel |
H61Y-P54100V H61Y-P57170V | Chromium-Molybdenum-Vanadium Steel | Chromium-Molybdenum-Vanadium Steel | Spring Steel | Chromium-Molybdenum-Vanadium Steel | Flexible Graphite | Chromium-Molybdenum-Vanadium Steel | Chromium-Molybdenum-Vanadium Steel | Chromium-Molybdenum Steel |
V. Structure Diagram:

| Industry Category | Machinery & Equipment/Valves/Check Valves |
|---|---|
| Product Category | |
| Brand: | 上海舟腾 |
| Spec: | H61Y |
| Stock: | 99 |
| Manufacturer: | 上海舟腾泵阀制造有限公司 |
| Origin: | 113120 |