China Early Suppression Fast Response ESFR Sprinkler K202 (Upright) - China Supplier
China Early Suppression Fast Response ESFR Sprinkler K202 (Upright) - China Supplier

Early Suppression Fast Response ESFR Sprinkler K202 (Upright)

Price:Negotiable
Industry Category: Security-Protection
Product Category:
Brand: 泰科TYCO
Spec: K202


Contact Info
  • Add:福建省晋江市池店镇华洲小区5幢商铺1408号, Zip: 362200
  • Contact: 叶经理
  • Tel:15060905319
  • Email:79592167@qq.com

Other Products

Description
Additional Information

I. Introduction to Early Suppression Fast Response (ESFR) Sprinkler K202 (Upright):

The Early Suppression Fast Response (ESFR) sprinkler is a large-orifice sprinkler head, serving as a key component in automatic fire suppression systems. It functions both to detect fires and to extinguish them through automatic water discharge. In the early stages of a fire, it thermally activates quickly and automatically, distributing water with a specific impulse in a defined shape and density over the designed protection area. It is a fire-suppression sprinkler head designed for early fire suppression. With its fast-response fusible alloy, large orifice diameter, and sizable deflector, its Response Time Index (RTI) is ≤28±8 (m·s)^0.5, offering advantages such as rapid fire response and high water flow rates. It is specifically designed to combat high-hazard warehouse fires and is used to protect high-pile and high-rack storage warehouses, as well as warehouses storing plastic products and mixed commodities.

II. Main Technical Performance Parameters of Early Suppression Fast Response (ESFR) Sprinkler K202 (Upright):

1. Installation type: Upright, with deflector facing upward; Pendant, with deflector facing downward.

2. Nominal diameter: 20mm, connection thread R2 3/4.

3. Rated working pressure: 1.2MPa, factory seal test pressure: 3.4MPa, 100% tested.

4. Flow coefficient: K=202.

5. Response Time Index (RTI) ≤28±8 (m·s)^0.5;

6. Nominal operating temperature: 74°C.

7. Minimum coverage area: 7.4m².

8. Maximum coverage area: 9.3m².

III. Storage, Installation, Usage, and Maintenance Precautions for Early Suppression Fast Response (ESFR) Sprinkler K202 (Upright):

1. Sprinkler heads should be stored in a dry environment between -15°C and 40°C and must not be used in environments below 4°C.

2. During installation, it is recommended to use polytetrafluoroethylene (PTFE) seal tape on the threaded connections between the sprinkler and pipe fittings. Pipe fittings should comply with national standards.

3. Installation must be performed using the appropriate wrench socket provided by the manufacturer for the sprinkler head, ensuring correct usage as shown in the figure below. The tightening torque for the sprinkler head is 10-20 N·m, and must not exceed 25 N·m. After installation, ensure they are neatly arranged to prevent damage from impact.

4. Sprinkler heads should be kept clean; painting or coating them with paint or other materials is strictly prohibited.

5. Sprinkler heads awaiting installation should be stored in the foam protective boxes provided by the manufacturer. Construction personnel must not use other containers, such as safety helmets or paint buckets, for storage or handling.

6. Handling sprinkler heads must be done gently; throwing, grabbing, or pouring them is not allowed. The fusible alloy element must not be subjected to impact. The company is not responsible for leaks or accidental discharges caused by improper handling or installation that damages the sprinkler frame, fusible alloy element, or support components.

Industry Category Security-Protection
Product Category
Brand: 泰科TYCO
Spec: K202
Stock:
Origin: China / Fujian / Quanzhoushi
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192