Factory air conditioning unit
Contact Info
- Add:广州市新塘镇荔新九路19号鑫潮科技产业园A5栋B区3楼, Zip:
- Contact: 罗经理
- Tel:13825096708
- Email:190946021@qq.com
Other Products
In a 1000 square meter workshop, selecting cooling equipment requires comprehensive consideration of the specific environment (such as ceiling height, heat source distribution, ventilation conditions, and local climate), budget, and cooling requirements. The following is a detailed analysis and recommended solutions for different scenarios:
1. Analysis of Key Influencing Factors
Workshop Environmental Characteristics
Ceiling Height: If the ceiling height is ≥4 meters, industrial large fans can be used to enhance air circulation; if the ceiling height is lower, focus should be placed on overall cooling equipment.
Heat Source Type: For workshops with high heat sources such as machining and welding, the equipment's heat dissipation capacity should be prioritized; for personnel-intensive workshops, human comfort should be emphasized.
Ventilation Conditions: Enclosed workshops rely on mechanical refrigeration, while semi-open or windowed workshops can combine natural ventilation to reduce costs.
Climate Zone: Dry northern regions are suitable for evaporative cooling, while humid southern regions should avoid increased humidity affecting effectiveness.
Budget and Operating Costs
Initial Investment: Central air conditioning > ducted air conditioners > evaporative air coolers > industrial fans + localized air coolers.
Long-Term Energy Consumption: Evaporative air coolers (low) < industrial fans (low) < spray cooling (medium) < central air conditioning (high).
2. Recommended Solutions by Scenario
Scenario 1: High-temperature dry regions (e.g., northern and northwestern China) with good ventilation
Recommended Solution: Evaporative air coolers (water curtain fans) + roof exhaust fans
Configuration Suggestions:
Install 1 evaporative air cooler (power 1.5-3kW) per 100-150㎡; 6-8 units are needed for 1000㎡, with a total investment of approximately 80,000-120,000 RMB.
Install water curtains on one side of the workshop and fans on the opposite side to create convection; add roof exhaust fans (1 unit per 200㎡) to accelerate hot air expulsion.
Cooling Effect: Can reduce ambient temperature by 5-10℃, significantly improving perceived temperature; hourly electricity cost is about 10-15 RMB (calculated for 8 units running).
Advantages: Moderate investment, low energy consumption (about 1/5 of air conditioning), suitable for personnel-intensive or general production workshops.
Scenario 2: Humid southern regions or workshops sensitive to humidity (e.g., electronics, food processing)
Recommended Solution 1: Industrial large fans + air coolers (localized cooling)
Configuration Suggestions:
Install industrial large fans (coverage diameter 10-15 meters, each costing about 3,000-5,000 RMB); 4-6 units are needed for 1000㎡, with an investment of about 20,000-30,000 RMB.
In fixed work areas or near equipment heat sources, pair with mobile air coolers (each costing about 2,000-3,000 RMB); 8-10 units are needed, with an investment of about 16,000-30,000 RMB.
Cooling Effect: Large fans enhance air circulation; air coolers provide localized cooling of 8-12℃, improving overall perceived temperature; annual electricity cost is about 10,000-20,000 RMB.
Advantages: Low investment, flexible and adjustable, avoids increased humidity, suitable for workshops not requiring overall cooling.
Recommended Solution 2: Central air conditioning / ducted air conditioners (for precise temperature control needs)
Configuration Suggestions:
Use variable frequency central air conditioning systems; calculate cooling capacity per square meter at 250-300W, total cooling capacity about 250-300kW, investment about 300,000-500,000 RMB.
Set up ducts and thermostats by zone for precise temperature control (18-26℃), paired with fresh air systems to improve air quality.
Cooling Effect: Constant temperature and humidity, suitable for high-end scenarios such as precision machining and clean rooms; annual electricity cost is about 100,000-150,000 RMB.
Advantages: Stable performance, but high initial investment and energy consumption, suitable for enterprises with sufficient budgets.
Scenario 3: Semi-open / outdoor workshops (e.g., storage, forging, welding areas)
Recommended Solution: High-pressure spray cooling system + industrial large fans
Configuration Suggestions:
Spray System: Install 1-2 atomizing nozzles per square meter, paired with a high-pressure pump (power 1-2kW), total investment about 50,000-80,000 RMB.
Industrial Large Fans: 4-6 units to enhance air circulation and accelerate water mist evaporation, investment about 20,000-30,000 RMB.
Cooling Effect: Can reduce ambient temperature by 5-8℃, significantly lowering perceived temperature; hourly electricity + water cost is about 5-10 RMB.
Advantages: Flexible installation, low cost, but spray volume must be controlled to avoid floor water accumulation (can be paired with humidity sensors for automatic start/stop).
3. Comprehensive Cost Comparison (for a 1000㎡ workshop, used 5 months per year, running 10 hours per day)
Solution Initial Investment Annual Operating Cost Applicable Scenarios
Evaporative Air Coolers + Exhaust Fans 80,000-120,000 RMB 15,000-20,000 RMB Dry northern regions, general production workshops
Industrial Large Fans + Localized Air Coolers 36,000-60,000 RMB 10,000-20,000 RMB Humid southern regions, non-overall cooling requirements
Central Air Conditioning / Ducted Air Conditioners 300,000-500,000 RMB 100,000-150,000 RMB High-end scenarios such as precision machining and clean rooms
Spray System + Industrial Large Fans 70,000-110,000 RMB 8,000-15,000 RMB Semi-open / outdoor workshops, high-temperature work areas
4. Optimization Suggestions and Considerations
Combine Insulation and Ventilation
Lay insulation materials on the workshop roof (e.g., polyurethane boards, cost 50-80 RMB per square meter) to reduce solar heat transfer and lower cooling equipment load.
Install skylights or ventilation louvers to use thermal pressure principles to expel top hot air, reducing equipment operation time (especially suitable for workshops with ceiling height ≥5 meters).
Energy Saving with Smart Controls
Evaporative air coolers and spray systems can be equipped with temperature sensors for automatic start/stop based on workshop temperature, avoiding无效 operation.
Central air conditioning should use variable frequency technology to automatically adjust power based on load, saving over 30% energy compared to fixed frequency systems.
Maintenance and Durability
Evaporative air coolers require regular water curtain replacement (1-2 times per year, cost about 200-300 RMB per unit) and tank cleaning to prevent algae growth.
Spray systems require softened water or regular nozzle cleaning (quarterly) to avoid scale blockage affecting atomization效果.
5. Summary and Recommended Priority
Best Cost-Effectiveness: Evaporative air coolers (water curtain fans) (suitable for dry northern regions, budget around 100,000 RMB,追求 low energy consumption).
Preferred for Humid Regions: Industrial large fans + localized air coolers (investment 50,000-80,000 RMB, flexibly addressing personnel and equipment heat dissipation needs).
High-End需求 Solution: Central air conditioning / ducted air conditioners (sufficient budget, strict temperature and humidity control requirements, e.g., precision manufacturing, electronics workshops).
Temporary / Semi-Open Scenarios: Spray cooling + industrial fans (investment 70,000-100,000 RMB, quickly降低 perceived temperature, suitable for outdoor or high-temperature work areas).
Final Recommendation: Contact professional refrigeration companies for on-site surveys to customize solutions based on specific heat source distribution, ventilation conditions, and local climate. If necessary, combine multiple equipment types (e.g., "evaporative air coolers + industrial fans") to ensure cooling效果 while minimizing costs.
| Industry Category | Machinery |
|---|---|
| Product Category | |
| Brand: | 瑞德 |
| Spec: | RLK-16 |
| Stock: | 999 |
| Manufacturer: | |
| Origin: | China / Guangdong / Guangzhoushi |