Unit Features
Integrated Small Water System Central Air Conditioning
Reed Home Triple-Supply Central Air Conditioning System meticulously selects all components of the system, including the air conditioning host, terminal equipment, integrated hydraulic module, valves, fan coil and underfloor heating thermostats, electric valves, etc., providing a comprehensive small water system solution for air conditioning. This greatly enhances system stability and installation convenience. Installation companies only need to provide wires, water pipes, and duct materials that have minimal impact on the system.
Comfort, Health, Safety, and Environmental Protection
1. Fluorine system indoor units may have excessively low or fluctuating outlet air temperatures, which can easily lead to "air conditioning sickness." In contrast, water system indoor units offer very stable outlet air temperatures, and the water supply temperature can be adjusted according to individual needs.
2. The water system host is connected to indoor air conditioning units via water pipes, with the refrigerant concentrated in the outdoor unit. Users do not need to worry about refrigerant leakage into indoor spaces, eliminating safety and health risks.
High Integration, Easy Installation, Flexible Control
1. Some triple-supply hosts come with built-in air conditioning water pumps and hot water pumps, significantly reducing on-site installation workload and ensuring a neat and tidy appearance.
2. The host can be linked with terminal devices such as fan coils, underfloor heating, and domestic hot water for one-touch control. Particularly for domestic hot water circulation, opening the faucet triggers the switch, starting the circulation pump to remove cold water from the pipes. This feature is highly practical for water and energy savings in small hotels.
-25°C Ultra-Low Temperature Jet Injection Heating, High Energy Efficiency Ratio
1. Based on ambient temperature, when it falls below the set value, the jet injection heating function automatically activates. After heating and condensation, the refrigerant temperature ranges between 40-60°C, retaining substantial heat. A flash evaporator further extracts this heat, increasing return gas pressure, reducing exhaust temperature, enhancing heating capacity, and improving the energy efficiency ratio.
2. Some models feature a side air discharge design, installed downwind in winter to minimize frost formation. They can operate normally even when the top is covered with heavy snow, protecting the fan blades and motor.
Reed Commercial Triple-Supply Central Air Conditioning System
Free Hot Water While Cooling, the Optimal Energy-Saving Solution for Hotels
Primarily used in large and medium-sized commercial buildings such as hotels, saunas, foot bath centers, bathhouses, apartment buildings, schools, hospitals, and office buildings.
Unit Features
Multi-Functional, Used in Combination with Dual-Supply Units
1. Air conditioning + underfloor heating + hot water: Generates free hot water while cooling, achieving 100% hot water energy savings.
2. For a hotel project, it is not necessary to install triple-supply units throughout. Triple-supply units only need to meet hot water demands, while dual-supply units can be used for other purposes, reducing project costs. Alternatively, some air conditioning systems can use triple-supply units while others use split air conditioners, also lowering project costs.
Comfort, Health, Safety, and Environmental Protection
1. Fluorine system indoor units may have excessively low or fluctuating outlet air temperatures, which can easily lead to "air conditioning sickness." In contrast, water system indoor units offer very stable outlet air temperatures, and the water supply temperature can be adjusted according to individual needs.
2. The water system host is connected to indoor air conditioning units via water pipes, with the refrigerant concentrated in the outdoor unit. Users do not need to worry about refrigerant leakage into indoor spaces, eliminating safety and health risks.
High Integration, Easy Installation, Flexible Control
1. Some triple-supply hosts come with built-in air conditioning water pumps and hot water pumps, significantly reducing on-site installation workload and ensuring a neat and tidy appearance.
2. The host can be linked with terminal devices such as fan coils, underfloor heating, and domestic hot water for one-touch control. Particularly for domestic hot water circulation, opening the faucet triggers the switch, starting the circulation pump to remove cold water from the pipes. This feature is highly practical for water and energy savings in small hotels.
-25°C Ultra-Low Temperature Jet Injection Heating, High Energy Efficiency Ratio
1. Based on ambient temperature, when it falls below the set value, the jet injection heating function automatically activates. After heating and condensation, the refrigerant temperature ranges between 40-60°C, retaining substantial heat. A flash evaporator further extracts this heat, increasing return gas pressure, reducing exhaust temperature, enhancing heating capacity, and improving the energy efficiency ratio.
2. Some models feature a side air discharge design, installed downwind in winter to minimize frost formation. They can operate normally even when the top is covered with heavy snow, protecting the fan blades and motor.