The application of computer control technology in this testing machine significantly enhances the system's self-monitoring capability. The testing system can complete test tasks or automatically and safely shut down upon reaching the preset fatigue cycles under unmanned conditions, achieving sample fracture protection and overload protection. This makes the testing machine easy to operate and greatly improves the level of automation.
This PLG-200 high-frequency fatigue testing machine is used to determine the fatigue characteristics, fatigue life, and fatigue crack pre-testing of metal and alloy materials (plates, bars) under tensile, compressive, or alternating tensile-compressive loads.
Performance Features:
1. The load drive is based on electromagnetic resonance, with very low energy loss, no wear during test loading, and simple equipment maintenance;
2. High frequency and short test cycles greatly save testing time;
3. No need to adjust the resonance magnetic gap;
4. Automatic calibration of the testing machine's accuracy;
5. Static and dynamic tests are supported by two separate systems, allowing independent loading without interference;
6. Automatic loading of static loads is achieved through [Static Locking];
7. Automatic search for resonance points, optimization of working parameters, and automatic completion of test control and measurement. The system automatically stops when the test reaches the set fatigue cycles or sample failure;
8. The self-diagnostic system periodically performs巡回自检 on the measurement and drive systems. When the system reaches software-set protection, mechanical limit protection, or encounters abnormal conditions such as load exceeding 110% of full scale, overvoltage/undervoltage, overcurrent, or communication errors, the system强制停机保护 and reports the status;
9. WINDOWS Chinese interface, button-based operation, user-friendly interface, online prompts, simple operation,轻松完成 test parameter setup, test control, data analysis and processing, direct display of engineering quantities such as static load, dynamic load, vibration frequency, and fatigue cycles, as well as statistical reporting and printing of test reports and curves.
Specification Item | PLG—100 | PLG—200 | ||||
Maximum Test Force | ±100kN | Maximum Test Force (kN) | ±200 | |||
Maximum Alternating Tensile-Compressive Load | ±50kN | Maximum Unidirectional Pulsating Load (kN) | ±200 | |||
Load Grading | 20%, 50%, 100% three grades | Maximum Dynamic Load (Peak kN) | 100 | |||
Static Load Indication Accuracy | ±0.5% | Relative Error of Static Load Indication | ±1% | |||
Fluctuation | Dynamic Average Fluctuation | ±1% | Relative Error of Static Test Force Repeatability | ±1% | ||
Dynamic Amplitude Fluctuation | ±2% | |||||
Frequency Range (Hz) | 60~250 | Frequency Range (Hz) | 50~250 | |||
Frequency Adjustment Levels | 5 levels | |||||
Test Space (mm) | Upper and Lower Test Space | 500 | Test Space (mm) | Upper and Lower Test Space | 700 | |
Left and Right Test Space | 500 | Left and Right Test Space | 600 | |||
Special Fixture for Fasteners | M14, M16 | |||||
Dimensions (mm) (L x W x H) | Main Unit | 720x600x2200 | Dimensions (mm) (L x W x H) | Main Unit | 1000x800x2550 | |
Electronic Control Unit | 550x550x750 | Electronic Control Unit | 550x550x750 | |||
Weight (kg) | Main Unit | 2200 | Weight (kg) | Main Unit | 5500 | |
Electronic Control Unit | 70 | Electronic Control Unit | 70 | |||