Heaters are mainly used for heavy diesel oil, fuel oil, lubricating oil, edible oil, high pour point crude oil, and storage tanks in cold regions that require heating to maintain the fluidity of the oil or meet the temperature requirements of the process. The products are divided into two types: steam coil heaters and local heaters.

Local heaters are installed at the outlet of the medium in tanks that already have coil heaters or in small-capacity storage tanks to increase the temperature of the medium inside the tank and reduce heating time.

Steam coil heaters calculate the required heating area based on the heating needs of the stored medium, and arrange and combine several unit coils in different configurations to ensure the smooth flow of the medium inside the tank, pump, and pipeline.

 1. Tank volume;         2. Tank diameter;

3. Stored medium;         4. Required material;

5. Flange standard pressure rating, nominal diameter;

6. Inlet and outlet steam temperature;   7. Inlet and outlet flow rate

III. Purpose of Oil Heating

   

Many oil products have high viscosity at low temperatures, and some waxy oil products may solidify due to wax crystallization at low temperatures.

The main purposes of oil heating in finished oil depots are:

Preventing oil solidification;

Reducing hydraulic friction during oil transportation in pipelines;

Accelerating the loading and unloading speed of tankers and oil tanks;

Dehydrating oil and settling impurities;

Accelerating oil blending and lubricant regeneration.

LTURQ New Type Tank Heater Models, Specifications, and Installation Dimensions

<極端 width="42" valign="center">

285

Model

Specification DN

Installation Dimensions

Connection Size DN

A

B

D

E

L

F

H1

H2

H

Steam Inlet a

Condensate Outlet

LTURQ-1.0-2

250

385

185

285

505

2990

250

500

360

786

40

25

LTURQ-1.0-3

300

385

185

285

505

3000

250

450

360

786

40

25

LTURQ-1.0-5

300

450

185

285

494

3050

250

450

360

786

40

25

LTURQ-1.0-7

300

450

185

285

494

3150

250

450

360

786

40

25

LTURQ-1.0-10

400

450

185

285

498

2600

270

500

400

866

40

32

LTURQ-1.0-12

400

450

185

285

498

3100

270

500

400

866

40

32

LTURQ-1.0-15

400

480

185

285

498

3600

570

500

400

866

40

32

LTURQ-1.0-20

400

480

185

285

498

4600

270

500

400

866

50

50

LTURQ-1.0-22

500

500

185

285

504

5975

300

500

450

966

50

50

LTURQ-1.0-25

500

500

185

285

504

3250

300

550

450

966

50

50

LTURQ-1.0-30

500

500

185

504

3650

300

550

450

966

50

50

LTURQ-1.0-32

500

500

185

285

504

3848

300

550

450

966

50

50

LTURQ-1.0-35

500

520

185

285

504

4250

300

550

450

966

極端

50

LTURQ-1.0-40

600

520

185

285

509

3690

320

600

500

1060

50

50

LTURQ-1.0-44

600

520

185

285

509

3996

320

600

500

1060

50

50

LTURQ-1.0-45

600

520

185

285

509

4060

320

600

500

1060

50

50

During daily operation inspections of the heater, attention should be paid to whether the condensate contains oil and whether there is an increase in water at the bottom of the tank. When not in use, the drain valve should be opened to discharge accumulated water. Before winter, inspections should be conducted to eliminate hidden dangers.

LTJRQ Series Tank Heater Technical Parameters

Tank Volume (m³)

Heater Model

Heating Area (㎡)

Steam Inlet/Outlet Connection Structure Type

Remarks

 

100

          

LTJRQ-1.0-4

LTJRQ-1.0-8

LTJRQ-1.0-11

4

<極端>

8

11

 

JCK-1 Type

 

(1) Flanges generally comply with the JB/T81-94 standard. Pressure rating is 1.6Mpa. If users require other standard flanges, such as SH, SY, GB, JIS, etc., they only need to specify when ordering.

(2) The heater models and specifications listed in this table are our company's standard products. If users need heaters of other specifications (i.e., heating areas), our company can also design and manufacture them.

(3) The material of this series of heaters is 20# seamless steel pipe. If special media are stored, our company can also provide heaters made of equivalent seamless steel pipe materials.

 

200

          

LTJRQ-1.0-8

LTJRQ-1.0-15

LTJRQ-1.0-20

8

15

20

 

JCK-1 Type

 

 

300

 

LTJRQ-1.0-10

LTJRQ-1.0-20

LTJRQ-1.0-25

10

20

25

 

JCK-1 Type

 

 

400

 

LTJRQ-1.0-15

LTJRQ-1.0-26

LTJRQ-1.0-29

15

26

29

 

JCK-2 Type

 

 

500

極端

LTJRQ-1.0-13

LTJRQ-1.0-21

LTJR極端-1.0-32

13

21

32

 

JCK-2 Type

 

 

700

 

LTJRQ-1.0-18

LTJRQ-1.0-29

LTJRQ-1.0-42

18

29

42

 

JCK-2 Type

 

 

1000

 

LTJRQ-1.0-20

LTJRQ-1.0-38

LTJRQ-1.0-45

20

38

45

 

JCK-2 Type

 

 

 

2000

 

LTJRQ-1.0-52

LTJRQ-1.0-29

LTJRQ-1.0-49

LTJRQ-1.0-90

52

29

49

90

 

JCK-2 Type

 

 

 

3000

 

LTJRQ-1.0-44

LTJRQ-1.0-71

LTJRQ-1.0-130

44

71

130

 

JCK-4 Type

 

 

5000

 

 

LTJRQ-1.0-43

LTJRQ-1.0-62

LTJRQ-1.0-99

LTJRQ-1.0-165

43

62

99

165

 

極端-4 Type

 

 

10000

LTJRQ-1.0-65

LTJRQ-1.0-115

LTJRQ-1.0-170

LTJRQ-1.0-280

65

115

170

280

 

JCK-4 Type

 

 


Industry Category Machinery & Equipment/Electric Heating Equipment/Annealing Furnaces
Product Category
Brand: 洪湖蓝天
Spec:
Manufacturer: 洪湖市蓝天安环节能设备有限公司
Origin: 114210
Storefront Language: English Chinese
About Toocle.com -  Toocle Partnership -  Toocle Services -  Toocle Agents
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192
ChatGlobal Chat Now