Toocle find for you 3122 information about the of-whatapp.hl.cn, total 100 pages
Application of Intelligent High-Pressure Spray Systems in Industrial Production
$2000
Category: Others
Company: 河南豪尔晟实业有限公司
Product Description: Application of Intelligent High-Pressure Spray System in Industrial ProductionHaorsheng Industry---Intelligent Technology High-Pressure Micro Mist System, through high-pressure pipelines to high-pressure nozzles for atomization, forms floating water mist, creating a good and fresh environmental air. The mist particles rapidly vaporize and interact with pollution factors through adsorption and decomposition, achieving effects such as deodorization, disinfection, moisturizing, and static elimination. It can also remove trace solid dust in the air, increase air humidity and negative oxygen ion concentration. Haorsheng Industry's high-pressure mist disinfection and deodorization equipment features fine mist and uniform spraying, with ideal diffusion effects.Breeding Farms: Sterilization, Disinfection, DeodorizationPrinting WorkshopApplication of high-pressure spray system can solve issues such as paper wrinkling and deformation, misregistration, rough printing, and low efficiency in the workshop, controlling humidity and improving quality.Electronics WorkshopApplication of high-pressure spray system rapidly increases air humidity with a large amount of water mist, solving dust and static electricity issues, preventing dust from adhering to components and electrostatic discharge from damaging electronic components, thereby improving quality.Textile WorkshopApplication of high-pressure spray system addresses issues such as flying fibers, lint, roller winding, and thread breakage through humidification, enhancing production efficiency and quality.Pharmaceutical Warehouse: Constant Temperature SystemGas StationApplication of high-pressure spray system addresses static electricity and dryness issues through humidification, resolving safety concerns. more>
Send Inquiry


Manufacturer of GPZ(KZ) 2DX±50 Seismic Basin-Type Bridge Bearings
Negotiable
Category: Others
Company: 衡水长江预应力有限公司
Product Description: GPZ(KZ) 2DX±50 Seismic Pot Bearing for Bridges ManufacturerThe GPZ(KZ) series seismic pot rubber bearings include two types: fixed bearings and unidirectional movable bearings, along with bidirectional movable bearings for配套 use. The bearing specifications are divided into 31 grades according to JT391-1999 requirements. The vertical design bearing capacity, bearing rotation angle, bearing friction coefficient, and displacement are all designed in accordance with standard requirements. Only the horizontal force in all directions of the fixed bearings and the non-sliding direction of the unidirectional movable bearings has been increased from 10% to 20% of the original bearing design capacity.Currently, both rigid seismic resistance and flexible shock absorption methods are adopted domestically and internationally. GPZ(KZ) 2DX±50 Seismic Pot Bearing for Bridges Manufacturer, Rigid seismic resistance requires increasing the size of the structure (including the foundation structure and seismic bearing structure). The characteristics of flexible shock absorption are: good shock absorption performance but relatively small stiffness, with the possibility of damage under strong seismic waves. This series of bearings adopts effective seismic measures such as a combination of rigidity and flexibility, increasing the energy dissipation capacity of the bearings and greatly improving their seismic performance.GPZ(KZ) 2DX±50 Seismic Pot Bearing for Bridges Manufacturer, Therefore, during an earthquake, it can enhance the bridge's seismic resistance,最大限度地 limit the relative displacement between the upper and lower structures of the bridge, and reduce the amplification factor of seismic forces. When there is no earthquake, it functions等同 to general pot rubber bearings.Since the GPZ(KZ) series seismic pot rubber bearings are designed with fixed bearings and unidirectional movable bearings, the combined use of these two types of bearings compared to installing seismic bearings only on the fixed piers of the bridge undoubtedly improves the seismic resistance of the entire bridge structure.Structural form of GPZ(KZ) pot rubber bearings: GPZ(KZ)GD (Fixed Seismic Pot Rubber Bearing), mainly GPZ(KZ) 2DX±50 Seismic Pot Bearing for Bridges Manufacturercomposed of an upper seat plate, energy dissipation plate, sealing ring, rubber plate, pot base, and damping rubber ring, etc. GPZ(KZ)DX (Unidirectional Movable Seismic Pot Rubber Bearing) also includes an intermediate steel plate, PTFE sliding plate, stainless steel sliding plate, and lateral sliding device, etc. The shock absorption principle is mainly that when the horizontal force on the bearing exceeds 20% of the design vertical bearing capacity, the energy dissipation plate begins to slide, providing the first isolation effect; then the damping ring发挥 the second damping effect, and the bearing serves its seismic role; when the seismic shock wave exceeds a certain limit, the rigid seismic resistance of this series provides the third seismic effect. more>
Send Inquiry

VR Practical Training System for Safe Operation of Underground Maintenance Mechanics
$4999
Category: Others
Company: 北京易妥科技有限公司
Product Description: System Content:Main modules include: Underground maintenance fitter operating procedures, pre-operation preparation training, maintenance operation training, equipment trial run operation process training, structure and usage training of commonly used tools and measuring instruments for fitters;Pre-operation preparation includes:Before equipment maintenance, prepare all necessary spare parts, materials, tools, equipment, and safety protection gear, and conduct thorough inspection and testing to ensure smooth maintenance and safe operation.Before operation, cut off or shut down the power, water supply, etc., of the equipment under maintenance and hang a "Work in Progress" warning sign.Before operation, carefully inspect the construction conditions of the work area to ensure the safety of personnel and equipment.Commonly Used Tools and Measuring Instruments for FittersTools: Scribers, scribing blocks, dividers, center punches, and surface plates for marking; hammers and chisels for chipping; various files for filing; hacksaws and blades for cutting; twist drills, countersinks, and reamers for hole processing; various taps, dies, and wrenches for threading; flat and curved scrapers for scraping; wrenches and screwdrivers.Measuring instruments: Steel rulers, knife-edge straight edges, inside and outside calipers, vernier calipers, micrometers, squares, protractors, feeler gauges, dial indicators.Maintenance Operation Training:1. The maintenance personnel's routine inspections and daily maintenance tasks for the equipment under their responsibility each shift are as follows:a) Check whether the components and parts of the maintained equipment are complete, intact, and reliable.b) Promptly inspect and address issues identified during equipment operation.c) Regularly adjust and test relevant safety protection devices to ensure they are safe and reliable.d) Check the hydraulic oil volume, oil quality, lubricating oil volume, and oil quality of various parts of the equipment to ensure they meet specified requirements.2. Perform maintenance and inspections according to the scheduled daily, weekly, and monthly check contents without missing any items.3. Master the equipment maintenance content, quality standards, and safety technical measures to ensure maintenance quality and safety.4. Place disassembled parts in designated locations without obstructing work or passage; ensure objects are securely placed.When disassembling equipment, follow the predetermined sequence. For parts with fixed relative positions or specific placements, disassemble according to markings.1. When disassembling larger components, take reliable measures to prevent falling or slipping.2. When disassembling components with elasticity, bias, or a tendency to roll, implement safety protection measures.3. When assembling or disassembling components, do not use brittle materials such as cast iron or cast copper, or materials harder than the components, as contact points.4. During maintenance, when opening covers, tank lids, or changing oil, cover them properly to prevent debris, water, etc., from entering.5. When assembling rolling bearings, if preheating is not feasible, use soft metal for padding during hammering or pressing.6. When changing or adding oil to equipment, ensure the grease type, purpose, and quality comply with regulations, and record relevant data.1. Conduct a comprehensive acceptance check for equipment after maintenance. Equipment requiring barring must undergo barring tests to check operational conditions.2. The trial run of equipment after maintenance should be uniformly directed by the work supervisor, operated by the driver, with dedicated personnel monitoring key areas.3. Assign dedicated personnel to monitor and address any issues promptly.4. Equipment should undergo trial runs after the following maintenance tasks:a) Repair or replacement of bearings;b) Major overhaul of motors, adjusting rotor and stator gaps;c) Overhaul of the hoisting system, track replacement, sheave replacement, connection device replacement, wire rope adjustment, brake system maintenance, major overhaul of the electrical system and winch body;d) Major overhaul of main fans, blade replacement, adjustment and maintenance of the electrical system;e) Replacement of main components of water pumps;f) Replacement of gears in reducers;g) Other items specified in the maintenance manual requiring trial runs.5. During trial runs, monitoring personnel should pay special attention to the following two points: 1. Temperature of rotating parts such as bearings;1. Vibration of rotating and transmission parts, operating sounds, and lubrication conditions;2. When working at heights or in shafts, wear safety helmets and secure safety harnesses, which should be locked in reliable positions.3. Parallel work above and below is strictly prohibited at heights and in shafts. If parallel work is necessary, develop reliable safety measures approved by the mine chief engineer and strictly implement them.Prohibit individuals with abnormal blood pressure, epilepsy, or other conditions unsuitable for working at heights or in shafts from participating in such tasks.System Features:1. User login and permission authentication;2. The system includes training mode and assessment mode. In assessment mode, the system can submit user assessment results to the backend management system;3. Supports user interaction with virtual equipment in the virtual environment via VR controllers;Supports users navigating the system via controller operation.Technology:The system is developed using the Unreal Engine, leveraging PBR materials for realistic virtual reality rendering of underground working environments. Particle systems are used to simulate effects such as water spray and dust during operations. more>
Send Inquiry

Calcium soap of rice bran wax
Negotiable
Category: Chemicals/Oxides/Calcium Oxide
Company: 湖州菁膳堂生物科技股份有限公司
Product Description: Rice Bran Wax Calcium Soap Product DescriptionRice Bran Wax Calcium Soap is produced through a high-temperature calcification process of rice bran wax. It is brittle, glossy, and has a dropping point of 98-108°C.ApplicationsCommonly used as an intermediate raw material in shoe polish, floor wax, polishing wax, and similar products.Product Specifications Item Specification Appearance Chocolate-colored solid block Dropping Point 90-110°C Wax Content (%) ≥90 Oil Content (%) 0-10 Acid Value (mgKOH/g) ≤5 Moisture ≤2% Lead (mg/kg) ≤3.0 Arsenic (mg/kg) ≤3.0 more>
Send Inquiry

Emergency Response Plan for Leakage of Sulfur-Containing Sewage Pump 215
Negotiable
Category: Chemicals/Oxides/Other Oxides
Company: 北京易妥科技有限公司
Product Description:        To enable users to understand the entire development process of the sulfur-containing sewage pump 215 leakage accident, personally experience the losses and damages caused by the sulfur-containing sewage pump 215 leakage accident to the surrounding environment, equipment, personnel, etc., and serve as a warning for emergency response. more>
Send Inquiry

HiCC-F Fully Automatic Zone of Inhibition Measurement System
Negotiable
Category: Instruments & Meters/Analytical Instruments/Other Analytical Instruments
Company: 杭州万深检测科技有限公司
Product Description: I. PurposeUsed for automatic measurement of inhibition zones, antibiotic potency analysis, etc.II. Main Technical Specifications1. Equipped with an A4-format color CCD dual-light source scanning imager (adjustable brightness, auto-focus), capable of achieving optical resolution of 40 million pixels with floating dark-field imaging. Features automatic enhancement imaging for inhibition zones.2. Compatible with petri dishes: 50–180 mm and rectangular plates within A4 format; can simultaneously measure 6 petri dishes of 90 mm.3. ★One-click fully automatic measurement of all inhibition zones in 1–6 petri dishes of 90 mm diameter. Capable of fully automatic measurement of partially adherent inhibition zones, automatically obtaining results such as inhibition zone area and diameter even with partial text interference. Can uniformly save or review various types of analysis data. Meets the requirements of all detection indicators in "JJF1614-2017 Calibration Specification for Antibiotic Potency Analyzers." Optional use of standard templates calibrated by legal metrology institutions for periodic instrument calibration.4. ★Features automatic selection of inhibition zone samples, true-to-life visual comparison, and editing functions. The inhibition zone measurement system has a reading resolution ≤0.001 mm; simultaneous analysis of 6 petri dishes takes ≤8 seconds. Measurement accuracy error for a 360° rotation with standard template ≤±0.05 mm; indication accuracy error with standard template ≤±0.05 mm; repeat measurement error ≤±0.01 mm; potency measurement accuracy error ≤±0.3%; inter-instrument measurement error ≤±0.3%.5. ★Complies with Chinese Pharmacopoeia, USP (United States Pharmacopeia), EP (European Pharmacopoeia), and British Pharmacopoeia. Capable of completing the latest national pharmacopoeia (2020 edition) one-, two-, and three-dose analyses, as well as combined calculations and antibiotic potency analysis for all bacterial strains. Features combined optimization analysis for potency.6. Measurement functions: fully automatic size calibration, with manual calibration option. Allows precise measurement of length, angle, arc, area, arc curves, and arbitrary curves via mouse drag.7. ★Data traceability and permission protection; operational records can be tracked and traced, complying with GLP and GMP requirements. Utilizes a multi-level system architecture with assigned functions and permissions to ensure data security, integrity, and authenticity. Features three-level hierarchical permission management:(1) System Administrator: Responsible for creating and managing all general administrator and operator accounts, setting permissions for general administrators and operators. There is only one system administrator with the highest system privileges. The system includes enhanced password strength requirements and account disablement functions.(2) General Administrator: Responsible for reviewing all test data, archive management, and managing other system data. Multiple general administrators can be assigned, with permissions set and allocated by the system administrator.(3) Operator: Responsible for sample preparation, testing, corrections, generating electronic reports, submitting for review, etc. Multiple operators can be assigned, with permissions set and allocated by the system administrator.(4) All accounts can modify their login passwords and set their electronic signatures for output in reports.(5) The system automatically records the operational history of each account. The system administrator can trace, review, and output these records. Features export and import of inhibition zone setting parameters, as well as automatic data saving.III. Standard Configuration1. HiCC-F Fully Automatic Inhibition Zone Measuring System Software USB drive and software lock (1 set)2. A4-format high-resolution color CCD dual-light source scanning imager (1 unit)Remarks:1. Items marked with ★ in this technical specification must be addressed; otherwise, it will be considered a major deviation.2. This product requires a computer. Recommended brand computer (12th Gen or higher Core i5 CPU / 16GB RAM / 21.5" color display / wireless network card, 1 USB 3.0 port + 3 USB 2.0 ports, operating environment: Windows 7, Windows 10, Windows 11).3. Optional HiCC series automatic inhibition zone measuring instrument dedicated standard plate (with one authoritative calibration certificate) (1 unit)4. Optional Oxford cup placement plate (4-well plate for two-dose, 6-well plate for three-dose), suitable for 90 mm petri dishes and 7.8 mm Oxford cups compliant with the new pharmacopoeia. more>
Send Inquiry

VR Practical Training System for Safe Operation of Underground Maintenance Mechanics
$4999
Category: Others
Company: 北京易妥科技有限公司
Product Description: System Content:Main modules include: Underground maintenance fitter operating procedures, pre-operation preparation training, maintenance operation training, equipment trial run operation process training, structure and usage training of commonly used tools and measuring instruments for fitters;Pre-operation preparation includes:Before equipment maintenance, prepare all necessary spare parts, materials, tools, equipment, and safety protection gear, and conduct thorough inspection and testing to ensure smooth maintenance and safe operation. more>
Send Inquiry


Installation Method of LBY-2 Roof Separation Instrument
Negotiable
Category: Others
Company: 泰安市九方矿山设备有限公司
Product Description: LBY-2 Roof Separation InstrumentThe roof separation instrument produced by Taian Jiufang Mining Equipment Co., Ltd. is a device used to monitor the displacement generated when the rock layers of a coal mine roof separate. It can monitor roof separation displacement and subsidence to prevent roof accidents. The instrument features high accuracy, intuitive display, low cost, simple installation, and time-saving observation. It provides scientific data for coal mine engineers and inspection personnel to understand the length and tensile strength of anchor bolts, as well as the rationality and economy of the anchor bolts and cables used.The roof separation indicator reflects the values of multiple fixed devices in the roof borehole, which change with rock layer movements, through measuring steel cables onto a reading device installed on the roof surface. The roof separation instrument serves mines with comprehensive product support;Features of the Roof Separation Instrument: 1.Measurement Method: Reflective color label direct reading;2.Number of Measurement Points: 2;3.Deep Base Point Range: 200 mm; Shallow Base Point Range: 150 mm;4.Reading Accuracy: 1 mm;5.Installation Borehole Diameter: 27-42 mm.6.Deep Base Point Steel Cable: 8 m, Shallow Base Point Steel Cable: 4 m, customizable.Taian Jiufang Mining EquipmentDW-4Multi-Point Displacement Meter, DW-3Type Roof Separation Instrument, Roof Subsidence Speed Alarm Detector, Jiufang MiningKBU101-200Roof Alarm Detector, YHW300Mine Roof Displacement Monitor, Jiufang MiningDigital Display Roof Separation Instrument, KY-82Roof Dynamic Instrument, JCY-100mMine Laser Rangefinder, YHJ-100JMine Laser Rangefinder, Jiufang MiningTray-Type Roof Separation Instrument, Borehole Stress Meter, GUD300Roof Displacement Sensor.Jiufang Mining EquipmentLBY-3TRoof Separation Instrument, LBY-3Roof Separation Indicator, ZKBY-2Roof Separation Instrument, Surrounding Rock Stress Sensor, Surrounding Rock Movement Sensor, Jiufang MiningYUD300Roof Displacement Monitor, LBY-2TRoof Separation Instrument, DLZ-IIRoof Separation Indicator, KGE30BRoof Separation Indicator, Jiufang MiningACLY-2Roof Separation Detector, DLY-3Roof Separation Instrument, Jiufang MiningDL-2Roof Separation Indicator, Jiufang MiningWBY-10Type Roof Separation Instrument, SMJ-2Roof Separation Instrument, DLJ-2Roof Separation Indicator, more>
Send Inquiry


Long-term supply of OPGW optical cables
$面议
Category: Electrical Equipment & Supplies/Wires & Cables/Other Wires & Cables
Company: 山东聚源电力物资有限责任公司
Product Description: OPGW cable (also known as Optical Fiber Composite Overhead Ground Wire) integrates optical fibers into the ground wire of overhead high-voltage transmission lines to form an optical fiber communication network along the transmission line. This structural design combines the dual functions of a ground wire and communication, commonly referred to as OPGW cable. A 250μm optical fiber is inserted into a loose tube made of high-modulus material, which is filled with a waterproof compound. The loose tube is longitudinally wrapped with a layer of double-sided plastic-coated steel tape (PSP), and water-blocking material is added between the steel tape and the loose tube to ensure the cable's compactness and longitudinal water resistance. Two parallel steel wires are placed on both sides, and a polyethylene sheath is extruded to form the cable.Features: 1. Suitable for high-voltage lines exceeding 110kV with large spans (generally over 250M).2. Easy maintenance and resolution of line crossing issues, with mechanical properties capable of meeting large-span line requirements.3. The outer layer of OPGW is metal armor, which is unaffected by high-voltage electrical corrosion and degradation.4. OPGW installation requires power outages, resulting in significant outage losses. Therefore, OPGW should be used in newly constructed high-voltage lines of 110kV and above.5. In OPGW performance indicators, higher short-circuit currents require better conductor materials for armor, which correspondingly reduces tensile strength. To increase short-circuit current capacity while maintaining a certain tensile strength, the metal cross-sectional area must be enlarged, leading to increased cable weight and diameter, thereby raising safety concerns for line tower strength.Structure: OPGW cables are primarily used in 500kV, 220kV, and 110kV voltage level lines. Due to factors such as power outages and safety, they are mostly applied in newly constructed lines. There are three main types: aluminum-steel type, aluminum skeleton type, and (stainless) steel tube type.Ordering Information: 1. Provide the application scenario, such as: mountains and forests, river crossings, bridge crossings, submarine, ducts, wind farms, etc.2. Provide design requirements including fiber count, model span, tensile strength, cross-section, material requirements, etc.3. Specify the cable type required, such as central tube structure or stranded tube structure.4. For custom orders, provide other known detailed technical parameters or design drawings.Our company produces and sells supporting products:Optical cable fittings, power fittings, line fittings, tension clamps, suspension clamps, optical cable splice closures, excess cable brackets, downlead clamps, pole clamps, tower fasteners, vibration dampers, vibration dampening whips, corona rings, grounding wires, pre-formed armor rods, pre-formed repair rods, pre-formed splice rods, safety backup clamps, fiber terminal boxes, fiber distribution boxes, fiber cross-connect boxes, fiber splitting boxes, cabinets, racks, ADSS cables, OPGW cables, OPPC cables, submarine cables,入户光纤光缆, etc. more>
Send Inquiry

Product characteristics of zinc alloy sacrificial anodes
$20
Category: Chemicals/Chemical Intermediates/Intermediate Compounds
Company: 焦作市立博轻合金股份有限公司
Product Description: Pei Yingying  1862587    9268Advanced DefinitionDefinition 8: The electrode with a more negative potential is called a sacrificial anode because, as the current continues to flow, the anode material is gradually consumed. As a sacrificial anode material, the metal or alloy must meet the following conditions: (1) The potential must be sufficiently negative to supply sufficient electrons to cause cathodic polarization of the protected metal equipment.System RequirementsSacrificial anodes are typically only economically applied to structures with low protective current requirements and in environments with low soil resistivity. Additionally, they are valuable when there is no power supply condition or when it is uneconomical.Sacrificial anode materials suitable for use in soil are primarily magnesium, while in seawater, zinc and aluminum are used. To maintain stable current output and reduce anode grounding resistance, chemical backfill should be used around sacrificial anodes in soil, mainly composed of 75% calcium sulfate, 20% bentonite, and 5% sodium sulfate. Sacrificial anodes should not be buried in coke. When used in groups, the distance between anodes should be at least 3m. The soil cover thickness above the anode should be at least 0.6m. To measure the off-potential, sacrificial anodes should be connected to the pipeline through a test box. When sacrificial anodes are used near AC traction systems, the continuous AC induced voltage on the anode body should not exceed 20V.Anode Requirements1. The potential must be sufficiently negative but not too negative to avoid hydrogen evolution reactions in the cathode region;2. The anode polarization rate should be low, and the potential and current output should be stable;3. The anode material should have a high electrical capacity;4. It must have high current efficiency;5. It should dissolve uniformly and detach easily;6. The material should be inexpensive and readily available;7. The corrosion products produced should be non-toxic, harmless, non-polluting, and pose no environmental hazards.UnderstandingElectrochemical oxidation of metals or alloys. The metal or alloy component is used as the anode, and an electrolytic method is employed to form an oxide film on its surface.The metal oxide film alters the surface state and properties, such as surface coloring, improving corrosion resistance, enhancing wear resistance and hardness, and protecting the metal surface. For example, aluminum anodizing involves placing aluminum or its alloys in a corresponding electrolyte (such as sulfuric acid, chromic acid, or oxalic acid) as the anode and performing electrolysis under specific conditions and with applied current. The aluminum or its alloy oxidizes at the anode, forming a thin layer of aluminum oxide on the surface, with a thickness of 5–20 micrometers. Hard anodized films can reach 60–200 micrometers. After anodizing, aluminum or its alloys exhibit increased hardness and wear resistance, up to 250–500 kg/mm², good heat resistance (the melting point of hard anodized films is as high as 2320K), excellent insulation (withstand voltage up to 2000V), and enhanced corrosion resistance (withstand thousands of hours in ω=0.03 NaCl salt spray without corrosion). The oxide film layer contains numerous micropores that can adsorb various lubricants, making it suitable for manufacturing engine cylinders or other wear-resistant parts. The strong adsorption capacity of the film micropores allows for coloring into various beautiful and vibrant hues.Non-ferrous metal alloy casting, anti-corrosion material sales, non-ferrous metal rolling processing; sales of high-performance non-ferrous metals and alloy materials, general equipment manufacturing; engineering technology, petroleum and natural gas technical services: wire and cable operations, marine energy systems and equipment manufacturing, sales of electrical instruments and meters, technical services, technical development, technical consulting, technical exchanges, technology transfer, technology promotion, import and export of goods.Pei Yingying 1862587  9268 more>
Send Inquiry

Product characteristics of zinc alloy sacrificial anodes
$20
Category: Chemicals/Chemical Intermediates/Intermediate Compounds
Company: 焦作市立博轻合金股份有限公司
Product Description: Pei Yingying   1862587  9268When cathodic protection is applied to a system, meaning a cathodic current is applied to polarize the cathode, the overall potential of the system shifts in the negative direction, such as to point 1. At this point, the total current on the cathode is I1, corresponding to the segment E1Q. Part of this current is externally applied, equivalent to segment PQ, while another portion still arises from the high corrosion of the anode, equivalent to segment E1P. It can be observed that the corrosion current I at the anode is smaller than the corrosion current Ic, indicating a reduction in the anode's corrosion rate and thus achieving a certain degree of protection.As the externally applied current continues to increase, the system's potential further shifts in the negative direction. When the potential reaches the equilibrium potential of the anode, the anode's corrosion current becomes zero, achieving complete protection. At this point, the cathodic current Ip (equivalent to the segment) is entirely externally applied. This externally applied current is referred to as the minimum protective current, and the corresponding potential is called the minimum protective potential (generally, polarizing the metal from its stable potential by 200–300 mV in the negative direction in seawater can achieve complete protection).(1) Main Parameters of Cathodic Protection: Protective PotentialProtective potential refers to the potential value required to halt metal corrosion during cathodic protection. To completely stop corrosion, the protected metal must be polarized to the active anode's open-circuit potential. For steel structures, this potential is the equilibrium potential of iron in the given electrolyte solution.The protective potential has a specific range. For example, the protective potential for iron in seawater ranges from -0.80 to -1.0 V (relative to a silver/silver chloride electrode). When the potential is more positive than -0.80 V, iron cannot achieve complete protection, so this value is also referred to as the minimum protective potential.The protective potential value is often used as a criterion to determine whether cathodic protection is complete. By measuring the potential values at various parts of the protected structure, the protection status can be assessed. Therefore, the protective potential value is an important indicator for designing and monitoring cathodic protection.2) Protective Current DensityThe current density required to reduce the metal's corrosion rate to an acceptable level during cathodic protection is called the minimum protective current density. The minimum protective current density corresponds to the minimum protective current. To achieve the minimum protective potential for the metal, the current density must not be lower than this value; otherwise, satisfactory protection cannot be attained. If the applied current density significantly exceeds this value, overprotection may occur, leading to excessive energy consumption and reduced protective effectiveness.As one of the main parameters of cathodic protection, the minimum protective current density depends on factors such as the type of metal being protected, the nature of the corrosive medium, the total circuit resistance in the protection system, the presence and type of coatings on the metal surface, and external environmental conditions. It must be determined based on experience and practical circumstances. Table 3-8 lists the required current densities for steel in different environments.(2) Factors Influencing Cathodic ProtectionSince cathodic protection is based on cathodic polarization of the protected metal's surface, the polarization characteristics of the original corrosion cell significantly impact cathodic protection.1) When the cathodic polarization is high and the anodic polarization is low, the corrosion of the protected metal is primarily cathodically controlled. In such cases, complete protection is easier to achieve. If the cathodic polarization curve falls within the diffusion-controlled region and the protective potential lies within this range, Ip is approximately equal to Icorr.2) When the cathodic and anodic polarization rates are equal, or when the anodic polarization is high, as shown in the polarization curve in Figure 3-7, achieving complete protection by bringing the system to the protective potential EA requires Ip >> Icorr, meaning the protective current must be much larger than the corrosion current.3) An increase in the corrosiveness of the surrounding medium will raise the required protective current. Increases in chloride ion concentration, oxygen content, and medium agitation speed (e.g., increased flow velocity in seawater) all reduce cathodic polarization, thereby increasing the current required for polarization and raising the protective current.Variations in the chemical composition of the medium, oxygen content, types of ions, and the amount of suspended matter all affect cathodic protection. Differences in oxygen content or changes in medium conductivity can alter the anodic polarization rate, causing the required cathodic protection current to change. An increase in suspended matter can cause abrasion on the cathode surface, reduce cathodic polarization, increase the corrosion current, and correspondingly raise the protective current.Temperature also affects polarization rates. An increase in temperature reduces oxygen solubility but accelerates diffusion and electrode reaction rates, ultimately increasing the protective current density.(3) Anti-Corrosion CoatingsAnti-corrosion coatings on metal surfaces can isolate the metal from the surrounding medium. However, since coatings are not entirely impermeable, they contain tiny pores and defects where localized corrosion can occur. The combined use of anodic protection and coatings protects these localized areas, resulting in a much lower required protective current density compared to bare metals during cathodic protection.During cathodic protection, a calcareous deposit layer forms on the anode surface due to an increase in pH, known as an electrolytic coating. This coverage increases surface resistance, reduces the corrosion current density, and enhances anti-corrosion effectiveness.Since the formation of a calcareous deposit layer significantly lowers the protective current density and makes potential distribution more uniform, the cathodic protection process often initially involves applying a higher current density to quickly form a dense calcareous layer on the surface, followed by a lower current density for maintenance.Pei Yingying   1862587   9268 more>
Send Inquiry

Bactericidal Algaecide Full Range of Agents for Sewage Treatment
$面议
Category: Others
Company: 辽宁碧水微澜科技有限公司
Product Description: Liaoning Bishui Weilan Technology Co., Ltd. is a professional water treatment company integrating: water treatment methods, mobile sludge dewatering and packaging one-stop services, dewatering equipment leasing, production, compounding, processing and sales of water treatment chemicals, water sample analysis and testing, paid on-site debugging, technology transfer and other businesses.Main production and sales: polyaluminum chloride (iron), composite double acid aluminum iron (special for plate and frame dewatering), polyferric chloride, composite carbon source, polyacrylamide, plate and frame filter press hydrophobic filter aid, activated carbon, retention and filtration aid, defoamer, decolorizing agent, bactericide, deodorant, corrosion and scale inhibitor, bactericidal and algicidal agent, cleaning pre-film agent, calcium oxide, calcium hydroxide, resin, heavy metal capture agent and other water treatment required products.The company's products and technologies are widely used in: water plants, sewage plants, sludge disposal centers, petroleum, petrochemical, drilling, papermaking, mineral processing and coal washing, leather, coal chemical, steel, printing and dyeing, food and beverage, pharmaceutical and pigment intermediates, chemical plants and other industries. Product IntroductionA broad-spectrum, high-efficiency bactericidal and algicidal agent specially developed for circulating water systems. This product is synthesized from polyquaternary ammonium salts and other monomers, and its bactericidal effect is significantly better than that of a single bactericide. It not only has good bactericidal and algicidal effects but also plays a certain role in preventing equipment corrosion.Product SpecificationsSpecification Name                          Technical SpecificationsAppearance                                  Colorless to light yellow viscous liquidActive Ingredient Content %                   20-24Ammonium Salt Content                         ≤2.0pH Value (1% aqueous solution)             6-8Product ApplicationWidely used for sterilization, algae killing, and corrosion prevention in various circulating cooling water systems such as power plants, steel plants, petrochemical plants, and central air conditioning systems.Usage Method and PrecautionsAdd directly, the dosage is generally 80-120g (the exact dosage should be determined according to the data specified in the operation plan). Wear latex gloves, protective goggles, and protective clothing. If splashed into the eyes, rinse immediately with plenty of water and seek medical attention promptly. more>
Send Inquiry

Design and Installation of Aluminum Alloy Sacrificial Anode Blocks
$21
Category: Metallurgy & Minerals/Non-Ferrous Processed Materials/Non-Ferrous Metal Sheets
Company: 焦作市轻合金股份有限公司
Product Description: Chang Qing 13939157916Design and Installation of Aluminum Alloy Sacrificial Anode BlocksAdvantages and Disadvantages of Aluminum Alloy Sacrificial AnodesAdvantages:High Electrochemical Activity: Aluminum alloy has high electrochemical activity, enabling it to quickly become the anode in a corrosion cell, preferentially dissolving and releasing electrons.High Cost-Effectiveness: Aluminum alloy offers good processability and cost-effectiveness, making it suitable for large-scale applications.Extended Service Life: The corrosion product film formed during the dissolution process of aluminum alloy can slow down the anode's dissolution rate, thereby extending its service life.Disadvantages:Localized Corrosion: The passive state of aluminum alloy in seawater is unstable, and localized corrosion is its primary form of corrosion.Aluminum Alloy Sacrificial Anode is a commonly used cathodic protection material, primarily employed for protecting metal structures in seawater environments. Its fundamental principle involves connecting the aluminum alloy sacrificial anode with the protected metal structure to form a galvanic cell through an electrochemical corrosion process. In an electrolyte solution (such as seawater), the aluminum alloy sacrificial anode acts as the negative electrode, preferentially losing electrons and being oxidized, thereby transferring electrons to the protected metal, lowering its potential, and inhibiting corrosion. more>
Send Inquiry

Develop various styles of marine zinc anodes ZH-5.
Negotiable
Category: Chemicals/Oxides/Zinc Oxide
Company: 焦作市轻合金股份有限公司
Product Description: Manufacturing various styles of marine zinc blocks ZH-5Zinc alloy sacrificial anodeThe anode has low self-solubility and good self-regulating performance for current generation; it offers a long protection period, up to 20-30 years, and generally avoids "over-protection" phenomena.Zinc alloy sacrificial anodes are suitable for cathodic protection against metal corrosion in seawater and brackish water environments, including ships, ballast water tanks, mechanical equipment, marine engineering and port facilities, drilling platforms, harbor terminals, condensers in seawater media, water pumps, as well as pipelines and cables in low-resistivity soil. tt20985553Implementation standard:· GB/T4950-2002Main performance:Marine zinc block, aluminum block prices, manufacturers· The anode has low self-solubility and good self-regulating performance for current generation; it offers a long protection period, up to 20-30 years, and generally avoids "over-protection" phenomena.Scope of application:· Zinc alloy sacrificial anodes are suitable for cathodic protection against metal corrosion in seawater and brackish water environments, including ships, ballast water tanks, mechanical equipment, marine engineering and port facilities, drilling platforms, harbor terminals, condensers in seawater media, water pumps, as well as pipelines and cables in low-resistivity soil. more>
Send Inquiry

Specifications, Models, and Prices of Aluminum Alloy Sacrificial Anodes
Negotiable
Category: Metallurgy & Minerals/Non-Ferrous Processed Materials/Non-Ferrous Metal Sheets
Company: 焦作市轻合金股份有限公司
Product Description: Specifications and Prices of Aluminum Alloy Sacrificial AnodesOur company develops and produces aluminum alloy sacrificial anodes (abbreviated as aluminum anodes) in accordance with GB/T 4948-2002. These are suitable for the cathodic protection of metals against corrosion in seawater environments, including ships, mechanical equipment, ballast water tanks, inner walls of storage tanks, coastal facilities, submarine pipelines, dock steel piles, offshore platforms, cables, and other facilities.Introduction to Aluminum Alloy Sacrificial Anode Products:Aluminum alloy sacrificial anodes comply with the standard GB/T4948-2002.Aluminum alloy sacrificial anodes are one of our company's main products. They are commonly used for the protection of seawater steel piles, seawater pipelines, inner walls of oil storage tanks, circulating water pipelines, ballast water tanks, and more. However, they are not recommended for use in soil environments. Their primary function is to provide corrosion protection and extend the service life of the protected structures. The production process is simple yet meticulous, with the alloy composition being crucial for the performance of the aluminum alloy sacrificial anodes. The proportion of components must strictly follow national standards, and each step of the process is carefully controlled by workers to deliver high-quality products that satisfy our customers.Introduction to Models and Specifications of Aluminum Alloy Sacrificial Anodes:Common specifications of aluminum alloy sacrificial anodes include 2kg, 10kg, 23kg, 35kg, 80kg, 120kg, etc.All specifications and dimensions can be customized according to customer requirements. For the inner walls of storage tanks, the commonly used standards are national standard AC-2 23kg and AC-1 35kg. Customization is also available based on design requirements, including specific composition ratios. Customers can purchase with confidence.Introduction to Our Company:Jiaozuo Libo Light Alloy Co., Ltd. specializes in the production and sales of sacrificial anodes. All anode specifications and dimensions are strictly manufactured step by step according to customer requirements, with rigorous inspection by quality control personnel. The anodes feature an attractive appearance, and their composition is verified by third-party testing. Our company also offers free material design assistance, technical guidance, and installation instructions for anodes. Our sacrificial anodes have gained recognition from many customers. We prioritize customer feedback and promptly address any issues, providing friendly service to every client. Our customers are the driving force behind our company's development. Thank you for your support, and we look forward to collaborating with you. You can trust us, and we await your call.Hello, I am from Jiaozuo Libo Light Alloy Co., Ltd., specializing in the production of: magnesium anodes, aluminum anodes, zinc anodes, zinc ribbons, magnesium ribbons, test stations, reference electrodes, deep well anodes, potentiostats, auxiliary anodes, cathodic protection construction, cathodic protection配套 products, couplers, and more. more>
Send Inquiry

Design and Production of 22kg Magnesium Alloy Sacrificial Anode
Negotiable
Category: Chemicals/Chemical Intermediates/Intermediate Compounds
Company: 焦作市轻合金股份有限公司
Product Description: Magnesium Anode | Magnesium Alloy Sacrificial Anode | Specialized Product for Buried Pipeline Corrosion ProtectionCommon Specifications and Models of Magnesium Alloy Sacrificial AnodesProduct NameModelBare Magnesium Anode Weight (kg)Specifications (Length × Width × Height mm)Magnesium Alloy Sacrificial AnodeSMG-44±0.2350×(75+85)×80Magnesium Alloy Sacrificial AnodeSMG-88±0.2700×(75+85)×80Magnesium Alloy Sacrificial AnodeSMG-1111±0.3700×(90+100)×90Magnesium Alloy Sacrificial AnodeSMG-1414±0.3700×(100+110)×105Magnesium Alloy Sacrificial AnodeSMG-2222±0.5700×(130+150)×1253. Backfill Material Formulation for Magnesium Alloy Sacrificial AnodesBackfill Material Formulation, Weight %Applicable ConditionsGypsum Powder(CaSO₄·2H₂O)IndustrialSodium SulfateIndustrialMagnesium SulfateBentonite500050≤20 Ω·m2502550≤20 Ω·m755020≥20 Ω·m15152050≥20 Ω·m1503550≥20 Ω·mThe pre-packaged magnesium alloy sacrificial anode was developed to ensure the construction quality of cathodic protection projects and simplify on-site construction procedures. It offers convenient and rapid installation by completing operations originally performed at the construction site in the factory, effectively ensuring the construction and installation quality of the anode ground bed.The pre-packaged magnesium alloy sacrificial anode was developed to ensure the construction quality of cathodic protection projects and simplify on-site construction procedures. It offers convenient and rapid installation by completing operations originally performed at the construction site in the factory, effectively ensuring the construction and installation quality of the anode ground bed.Component Configuration:· One sacrificial anode of any model.· One cable conductor: Welded to the sacrificial anode according to the customer's design requirements for length and specifications, and sealed with epoxy resin and dibutyl phthalate in proportion using glass fiber cloth or PVC heat-shrink sleeve.· One bag of specialized backfill material.· One anode cloth bag.Product Model: Magnesium Alloy Sacrificial Anode (Magnesium alloy sacrificial anode) more>
Send Inquiry

Construction of the Foundation for Multi-Span Film Greenhouse
$10
Category: Others
Company: 河南绿联环保技术有限公司
Product Description: A multi-span film greenhouse is an efficient and energy-saving agricultural facility suitable for large-scale cultivation, seedling propagation, or scientific research and production. Its foundation construction is a core step to ensure the structural stability and service life of the greenhouse. Below is a detailed process and key points of its foundation construction.I. Pre-construction Geological SurveyConfirm soil bearing capacity through geological exploration (recommended ≥120 kPa), groundwater level, and frost depth (in northern regions, deeper burial is required to prevent frost). Level the terrain: remove weeds and stones to ensure a site slope ≤3% and avoid water accumulation. Confirm drawings: design foundation dimensions and layout based on greenhouse span (commonly 8m/9.6m) and height (eave height 3-4m, ridge height 5-6m).II. Material PreparationC25/C30 concrete, Φ12-16mm threaded steel bars (foundation reinforcement), embedded parts (anchor bolts/steel plates). Auxiliary materials: PVC drainage pipes, weed barrier fabric, waterproofing membrane. Tools: total station (for positioning), excavator, vibrator, formwork (steel or wood).III. Foundation Construction Process1. Setting out and positioning: Mark column positions with a total station according to the drawings, with an error ≤2cm. For multi-span greenhouses, ensure alignment of adjacent span axes to avoid deviations during frame installation.2. Foundation treatment: Excavate pits; single-column foundation dimensions are typically 50×50×60cm (L×W×D), with a 10cm gravel cushion at the bottom. Reinforcement: configure 4 Φ12mm longitudinal bars + stirrups @200mm, and embed anchor bolts (exposed 15-20cm). Pouring: pour concrete in layers, compact with vibration, finish the surface, and cure for 7 days. Excavate trenches 40cm wide and 50cm deep, configure continuous reinforcement cages, and embed column connection plates.3. Ring beam construction: For spans ≥10m or areas with high wind, add a ground ring beam (cross-section 30×30cm) to enhance overall wind resistance.4. Drainage system: Dig drainage ditches around the greenhouse (30cm wide × 40cm deep) with a 0.5% slope, lined with PVC pipes or brickwork for diversion.5. Embedded part calibration: Correct the position of anchor bolts before initial concrete setting, with horizontal error ≤3mm and elevation error ≤5mm.IV. Key Quality Control Points1. Concrete strength: 28-day compressive strength must meet design values (C25≥25MPa); add antifreeze agents for winter construction.2. Settlement prevention: In soft soil areas, replace with sand and gravel or reinforce with piles (e.g., pipe pile depth ≥2m).3. Rust and corrosion prevention: Embedded steel components must be hot-dip galvanized (zinc coating ≥80μm), with welded areas recoated with anti-rust paint.4. Wind resistance design: Foundation burial depth must exceed the local maximum frost depth by 30cm (e.g., burial depth ≥1.2m in northeastern regions).V. Construction Safety and Environmental Protection1. Set up警戒 zones when operating machinery; wear hard hats and reflective vests.2. Sort and stack waste concrete and debris to avoid contaminating farmland.3. Cover with waterproof tarps during rainy season construction to prevent foundation pit collapse.VI. Common Issues and Solutions1. Uneven foundation settlement: Immediately stop construction and use grouting reinforcement or additional piling.2. Embedded part deviation: Correct by welding steel plates; if deviation >10mm, reinstall reinforcement.3. Poor drainage: Add catchment pits or enlarge drainage ditch cross-sections.Through scientific and standardized foundation construction, multi-span film greenhouses can withstand Level 10 winds and 20cm snow loads, with a service life of over 15 years. Henan Green Union Greenhouse designs and constructs various types of greenhouses, with an experienced construction team and professional after-sales service. Customers in need are welcome to inquire and purchase. Service hotline: 13333863757 more>
Send Inquiry